12 13 15 M4 X 0.7 4.3 4.3 5.6 5.6 M5 X 0.8 6 8 10 12 58 64 83 93 8 8 9.5 9.5 13 M4 M4 M5 M5 4.5 4.5 5.5 5.5 8 8 8 10 10 13 15 18 21 18 13 15 18 21 5 5 6 6 18 22 24 30 12 16 20 25 26 30 36 42 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200, 250 20, 30, 40, 50, 75, 100 125, 150, 175, 200 250, 300, 350, 400 46 33 11 M5 X 0.8 M5 X 0.8 M5 X 0.8 15 10 19 MGC 53 37 10.5 M5 X 0.8 M5 X 0.8 Rc1/8 12.5

10 118 89 Bore size [mm] e d f l h 1 to 50 901 to 1000 32 36 54 23 12.5 25 37.5 50 75 100 125 150 175 200 225 250 75 88 100 113 138 163 188 213 238 263 288 313 40 36 54 23 12.5 25 37.5 50 75 100 125 150 175 200 225 250 75 88 100 113 138 163 188 213 238 263 288 313 50 51 64 25 12.5 25 37.5 50 75 100 125 150 175 200 225 250 87 100 112 125 150 175 200 225 250 275 300 325 63 51 64 25 12.5

CG-020-24A CG-025-24A CG-032-24A CG-040-24A 8 +0.4 +0.1 41 +0.4 +0.1 48 +0.5 +0.1 48 +0.5 +0.1 56 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 8 +0.036 0 31 37 38.5 42.5 5.5 5.5 6.6 6.6 42 48 53 60 20 25 32 40 10 10 10 10 (29.3) (33.1) (40.4) (49.2) 25 30 35 40 5.5 5.5 6.6 6.6 10 10 10 10 36 43 50 58 20 25 32 40 10+0.036 0 10 12 14 12+0.036 0 14+0.043 0 Tube dia. (mm) Tube dia.

8 15 13 3.5 1.5 5.5 200 200 10 107.0 108.0 107.5 108.0 154 164 12.5 10.5 17.5 15.5 6 4 8 D-Y7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL Operating Range Auto switch model Bore size (mm) 125 140 160 180 200 D-Z7/Z80 14.5 14 13 14 14.5 Hs D-A3/A44 D-A5/A6 A 10 10 10 10 10 D-A59W Ht 17 17 17 17 17 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV 8 7.5 7 12 13 D-Y7BAL 7 7 7 6 6 B D-F5/J5

2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D.

connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)

PF3W711/511-;10 p10 (at 100 L /min) PF3W711/511-;06 PF3W721/521-;14 p8 (at 50 L /min) (at 250 L /min) p6 p4 PF3W721/521-;12 PF3W711/511-;10 (at 50 L /min) p2 (at 250 L /min) p0 0 2 4 6 8 10 0 2 4 6 8 10 Straight piping length [cm] Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions. 5 Digital Flow Switch for Water Series PF3W 3

SS5V2-10 SS5V3-10 SS5V4-10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.

Purchasing order is available in units of 10 pieces.

8 16 10 12 12 8 10 10 41 5 8 31 25 to 300 15.5 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 25 to 400 19.5 32 24 22 38 16 14 19 11 13 13 8 10 10 53 8 9 40 25 to 500 21 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 25 to 500 21 (mm) Bore size (mm) K MM NA NB NN P S T V W ZZ IA 0.020 0.053 0.020 0.053 0.025 0.064 0.025 0.064 20 5 M8 x 1.25 17 15 M22 x 1.5 1/8 81 9.5 4.5 6.5 138 23f8

(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment. 4 4 4.5 5 6 6.5 6.5 7 8 10 9 10 10 11 D8 10 9 10 10 11 5 5 5.5 6 7 7.5 7.5 8 11 11 13 13 14 14 14 17 35 40 40 45 45 45 45 50 16 18 -X 8 10 9 10 10 11 Individual -X 387 Series MGG Auto Switch Mounting Bracket: Part No.

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B,

Bore Size: 20mm, Port Type: N (NPT), Stroke: 250mm, Lock Position: H (Rear Locking), Manual Override: N (Non-locking Type), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: M9B,

(mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 150, 200, 250, 300 500 10 150, 200, 250, 300, 350, 400 450, 500 750 15 20 1000 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 1500 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 1500 Note) Intermediate strokes can be arranged in 1mm increments.

10 10 10 ORIG sensor 0 0 0 0 ORIG SW Dir 0 0 0 0 Undefined parameter21 0 0 0 0 87 - Appendix 1.2 LEF series setting value LEFS Step data default Model LEFS16 LEFS25 LEFS32 LEFS40 Lead [mm] 10 5 20 12 6 24 16 8 30 20 10 No. 0 0 0 0 Movement MOD ABS ABS ABS ABS to 500 500 250 1000 500 250 1200 500 250 500 500 250 Speed Strok 501-600 900 500 250 1200 500 250 500 500 250 601-700 630 420 230

Note 10) A reference value for correcting an error in reciprocal operation. Switch and Acceleration Note) Table 2 Switch no. Acceleration [mm/s2] 0 250 1 500 2 1000 3 1500 4 2000 5 2500 6 3000 7 4000 8 5000 9 6000 10 7500 11 10 12 12500 13 15000 14 17500 15 20 Note) The factory default setting for the switch is No.0.

One-touch fitting 06 08 10 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting Power supply cable Refer to the table below for selection of One-touch fittings.