Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, "SPEED CONTROLLER, FLOW CONTROL
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CNTL METAL BODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, AX, AS M5 (MISC./OTHER), .03472 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, CX, AS 1/8INCH (MISC./OTHER), .07920 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CNTL METAL BODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, CX, AS 1/8INCH (MISC./OTHER), .07310 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, "SPEED CONTROLLER, FLOW CONTROL
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, AIR SAVING PRESSURE VALVE, AIRLINE EQUIPMENT, ASR METERED QUICK EXHAUST, DB, ASR 1/4INCH STANDARD (PT), .02776 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, AIR SAVING FLOW VALVE, AIRLINE EQUIPMENT, ASQ INLINE QUICK EXHAUST, DB, ASQ 1/4INCH STANDARD (PT), .33550 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, Speed Controller with Indicator, FLOW CONTROL, 24 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, Speed Controller with Indicator, FLOW CONTROL, 24 lb
Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 02 (1/4), Applicable Tubing O.D: 08 (ø8), Sealant: S (w/Sealant)
Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 02 (1/4), Applicable Tubing O.D: 06 (ø6), Sealant: S (w/Sealant)
Body Size/Type: 22 (Elbow Size 01, 02 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: 02 (1/4), Applicable Tubing O.D: 06 (ø6)
Size: 02 (Size 02), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A01 (Side Ported, 1/8), Thread: T (NPTF)
Size: 02 (Size 02), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: None, Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: Rc
Size: 02 (Size 02), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: Rc
Size: 02 (Size 02), Passage Symbol: FIG (3 Position Pressure Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: Rc
Size: 02 (Size 02), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: Rc
Size: 02 (Size 02), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 02 (Size 02), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A01 (Side Ported, 1/8), Thread: F (G)