SMC Corporation of America
Elite Part Number Search
Search Results "PFM511S-N02-2-N"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]

Body Option: 0 (Internal Pilot), Port Size: N02 (NPT1/4), Style: 34 [Twist Selector (2 Position)], Suffix: R (Push Button Selector Color Red), Accessory: F [Foot Bracket (Internal Pilot Type Only)

also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 135 lb

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve: ZS-33-M

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

This is a legacy product, and replaced byZH13DSA-N01-N02-N02, VACUUM EJECTOR, 1/8 SUP, VACUUM SERIES, ZH VACUUM EJECTOR, DD, ZH NOZZLE SIZE 1.3, .11660 lb

Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4)

Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4)

This is a legacy product, and replaced byZH13DSA-N01-N02-N02, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .08250 lb

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, F29, 135 lb

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.54081 lb