Options include auto-switch capabilities, free mount choices, recessed switch mounting gr COMPACT CYLINDER. Cyl, Free Mount. 218 lb. 539.
Options include auto-switch capabilities, free mount choices, recessed switch mounting gr COMPACT CYLINDER. Cyl, Free Mount. 694 lb. 539.
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor: w/Light Surge Voltage
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor: w/Light Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor: w/Light Surge
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor: w/Light Surge
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor: w/Light Surge Voltage
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC