SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1X200-0600-A54-XC6"

Magnet: Built-in Magnet, Mounting: Basic, Cushion: Adjustable Air Cushion, Bore Size: 63mm, Stroke: 6", Auto Switch: M9NAV--Solid State, Water Resist., 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Made to Order: XC6

Magnet: Built-in, Mounting: MF2, Rear Flange, Bore Size: 1 1/2", Stroke: 6", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 3 pcs., X Option: Stainless Steel Rod

Magnet: Built-in, Mounting: MT4, Center trunnion, Bore Size: 2 1/2", Stroke: 6", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Magnet: Built-in, Mounting: MP1, Double Rear Clevis, Bore Size: 4", Stroke: 6", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Magnet: Built-in, Mounting: MF1, Front Flange, Bore Size: 3 1/4", Stroke: 6", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder

Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting

Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting

NPN) IC Terminal conduit 12 V M9NW M9PW M9BW M9NA1 M9PA1 M9BA1 F59F 5 V, 12 V IC Diagnostic indication (2-color indication) Relay, PLC Yes 12 V 24 V 5 V, 12 V IC Water resistant (2-color indication) Grommet IC 12 V 5 V, 12 V With diagnostic output (2-color indication) 2-wire (Non-polar) Magnetic field resistant (2-color indication) P4DW 3-wire (NPN Equivalent) A96 IC 5 V Yes A93 A90 A54

Relay, PLC 12 V 2-wire 3-wire (NPN) 5 V 12 V IC circuit Diagnostic indication (2-color indication) 24 V 3-wire (PNP) 40 to 100 12 V Grommet 2-wire Water resistant (2-color indication) 40 to 160 With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit Magnetic field resistant (2-color indication) P5DW 40 to 100 2-wire Lead wire length symbols: 0.5 mNil (Example) A54

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.

Relay, PLC 12 V 2-wire 3-wire (NPN) 5 V 12 V IC circuit Diagnostic indication (2-color indication) 24 V 3-wire (PNP) 40 to 100 12 V Grommet 2-wire Water resistant (2-color indication) 40 to 160 With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit Magnetic field resistant (2-color indication) P5DW 40 to 100 2-wire Lead wire length symbols: 0.5 mNil (Example) A54

Indicator light Auto switch model Load voltage Wiring (Output) Pre-wire connector Special function Electrical entry Applicable load Type 5 (Z) 0.5 (Nil) 3 (L) Tie-rod mounting Band mounting AC DC In the case of built-in magnet without auto switch, the symbol for auto switch is Nil. 3-wire (NPN equivalent) IC circuit Z76 5 V Grommet Z73 100 V Relay, PLC Reed switch Solid state switch A54

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z There are other applicable auto switches than listed above. For details, refer to page 9-8-22.