capacity (cm3) 55 135 7 135 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (with no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Standard Option Weight (kg) 0.47 0.24 1.13 0.07 0.52 1.06 0.20 Notes 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C
Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020
At circulating water temperature 20c, cooling water temperature 25c, 30l/min or less (water-cooled), and ambient temperature 32c (air-cooled)
210 210 250 200 230 320 385 335 380 210 240 200 230 170 200 175 210 165 195 165 195 165 195 165 195 165 195 50Hz 60Hz 50Hz 60Hz AC 100V AC 200V Power consumption (W) Note2) 50/60Hz Refrigerant Air connection Weight R134a 28 Rc3/8 23 Rc1/2 27 Rc3/4 28 Rc3/4 27 23 Rc1/2 22 18 Rc3/8 17 16 (kg) White1 (Munsell 10Y8/0.5) Coating color Note1)The data for l/min (ANR) is under the conditions of 20C
(coil temperature 20C (68F), at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
NO OFF n-2 n-1 Real-time flow rate Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
frequency 1kHz Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light 10 to 55C Ambient temperature 25 to 70C Environmental resistance 45 to 85% RH Ambient humidity Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C
lead wire (length 300mm) M: With lead wire (length 300mm) MN: Without lead wire D: With connector H: Lead wire length 600mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector Types LN and MN are equipped with sockets (2pcs.). 2 Series SY3000/5000/7000 Specifications Response Time Note) Based on JISB8375-1981 dynamic performance test (coil temperature 20C
Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C, at rated voltage). (B) 2 (A) 4 Weights SOL.b SOL.a 3 (EB) 5 (EA) Series Type of actuation Weight g (lbs) Single solenoid 66 (.14) 1 (P) Double solenoid 71 (.15) 4 position dual 3 port valve: N.O./N.O.
(Initial value) Solenoid Specifications 24VDC 10% of rated voltage 0.55W Diode LED Rated coil voltage Allowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
(Coil temperature: 20C, at rated voltage, without surge suppressor) SY3000 SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Type of actuation Without light/surge voltage suppressor 12 or less Type of actuation Without light/surge voltage suppressor 31 or less Type
(Coil temperature: 20C, at rated voltage) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
L type (for plug-in) Electrical entry Rated coil voltage 24VDC 10% of rated voltage Allowable voltage fluctuation 0.65W Power consumption Diode Surge voltage suppressor LED Indicator light Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Min. bending radius (mm) 15 Note 3) Note 4) 20 35 60 95 100 130 Air, Inert gas: -20 to 200C Water: 0 to 100C (No freezing) Operating temperature 2R Material FEP (Fluorinated Ethylene Propylene Resin) At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 5%.
Solenoid Specifications Rated coil voltage Allowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light 24VDC 10% of rated voltage 0.65W Diode LED Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area
(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.
Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C 20C