For Air Upstream pressure of valve P1 z 1.0 MPa Downstream pressure of valve (P2) [MPa] 1.0 0.8 Subsonic Critical 0.9 0.6 pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 2 50 100 150 200 250 300 400 350 3 100 200 300 400 500 4 400 600 800 1,000 1,200 5 200 1,400 600 1,000 7 350 700 8 400 700 1,000 1,300 10 500 700 10 700 1,000 Flow rate Q [L/min (ANR)] How to read the graph The sonic
300 600 0 150 100 50 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-D AFD40-D 0.02 0.02 Pressure drop [MPa] Pressure drop [MPa] P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa P1 = 0.7 MPa 0.01 0.01 0 0 0 600 400 200 800 1000 0 100 200 500 400 300 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 72 AFM20-D to AFM40-D Series AFD20-D to AFD40-D Series Dimensions
Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.
Load mass kg Load mass kg MY2HT25 Horizontal impact: P = 0.5MPa MY2H25 Horizontal impact: P = 0.5MPa 2000 1500 2000 1500 H unit Impact speed mm/s Impact speed mm/s Impact speed mm/s 1000 1000 H unit L unit 500 400 300 500 400 300 L unit Air cushion Air cushion Caution 200 200 Do not use a shock absorber and air cushion together. 100 1 2 3 4 5 10 20 50 40 1001 2 3 4 5 10 20 30 4050 30 Air
Outlet air flow rate (L/min (ANR)) 0 200 400 600 800 1000 1200 Outlet air flow rate (L/min (ANR)) 0 500 1000 1500 2000 Outlet air flow rate (L/min (ANR)) Pressure Characteristics Pressure Characteristics Pressure Characteristics Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure
Find the energy cost per hour of a double acting cylinder with an 80 mm. dia. and a 400 mm. stroke with t2 double strokes per minute and a working pressure of 6 bar In table 6.19 we see that an 80 mm dia. cylinder consumes 3.5 liters (approx.) per 100 mm stroke so: O /100 mm stroke . 400 mm stroke . number ot strokes per min . forward and retum stroke = 3.5 ' 4 . 24 = 336 Umin.
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
Stroke length tolerance 10-/11-: 30 to 400 mm/s, 21-/22-: 50 to 400 mm/s Piston speed +1.4 0 Mounting Basic/Axial foot/Flange 10-/11-: Fluorine grease 21-/22-: Lithium soap based grease 10-: Class 4, 21-: Class 5 11-/22-: Class 3 Grease Refer to page 889 for the applicable auto switch list.
350, 400, 450, 500, 600, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm increments up to the maximum strokes
400 300 200 100 0 VQ2101 Port size: 8 One-touch fitting It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow-rate characteristic graphs.
Since 45% of the amount of clear water discharge is equivalent to 180 mL/min in the required specifications, 180 mL/min 0.45 = approximately 400 mL/min, indicating that a discharge rate of 400 mL/min is required for clear water. 3. Finally, find the pilot air pressure and pilot air consumption based on the flow rate characteristic graphs.
Dimension L (mm) Dimension L (mm) Dimension L (mm) Dimension L (mm) Station 2 3 4 5 6 7 Station 14 15 16 17 18 19 Station 20 21 22 23 24 Station 8 9 10 11 12 13 SE 165 175 190 205 215 230 245 260 280 290 300 310 400 405 420 435 450 320 335 350 365 375 385 SSQ1000 Note) Part number for a 10 piece set of elements. Refer to page 134 for replacement procedures.
, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 (Both sides) 1300 25 12-CY3B25 Non-lube 32 12-CY3B32 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B40 40 Note 1) Stroke exceeding the standard stroke but below the maximum possible stroke is available for special order upon request.
MGCM Slide bearing Data 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 40 200, 250, 300 Ball bushing bearing 700, 800 MGCL 350, 400, 450, 500, 600, 50 700, 800, 900, 1000 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
[kPa] 8 8 AFJ40-04-80-T 6 6 4 4 2 2 Water drop removal type Nominal filtration rating: 80 m Large flow type Nominal filtration rating: 80 m 0 0 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min(ANR)] 0 100 200 300 400 500 600 800 700 900 Flow rate [L/min (ANR)] 783 AFJ20 to AFJ40 Series Construction AFJ20 AFJ30, AFJ40 OUT IN OUT IN q q r r w w (y) e (y) t e t Component Parts No.