IDFB Series 9-4Electric circuit 9 2 IDX-OM-W034 Air Dryer 10 Specification for Option S 10 Specification for Option S 10-1 Safety instructions When handling the product, take care to the following precautions. For IDFB22E-11 Only qualified persons are allowed to wire the product. Warning 1. Before wiring, be sure to shut off the power supply.
E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110] [250] [50] [13] [5002] [75] [7001] [526] [5195] [36] 35.4 38.1 IDFB75E 2 [900] [968] IDFB Series 6-3 6-2 IDX-OM-W035 6 6-4 IDFB22E-11 IDFB22E/37E-23 R GFCI GFCI R GFCI R GFCI L N PE R TB1 PE N L 1 2 TB1 1 2 1 2 S MC S C1 IDFB22E
PRODUCT SPECIFICATIONS S E R I E S I P 5 0 0 0 / I P 5 1 0 0 IP5000 (Linear) IP5100 (Rotary) SERIES 20 100 psi SUPPLY PRESSURE STROKE SENSITIVITY LINEARITY HYSTERESIS 0.4" 3.4" 60 100 degrees WITHIN 0.1% F.S. WITHIN 0.5% F.S. WITHIN 1% F.S. WITHIN 0.75% F.S. WITHIN 1% F.S. WITHIN 2% F.S. WITHIN 0.5% F.S.
IO-Link 1.0 IO-Link -81No.PS-OMV0003CN-G ISE70 ISE71 01.000 MPa 01.600 MPa / -0.1051.050 MPa -0.1051.680 MPa / 0.001 MPa 1.5MPa 2.4 MPa DC1224 V10(p-p)10 IO-Link DC1830 V (p-p)10 35 mA 2% F.S.1 digit(253 ) 0.5F.S. 2%F.S.(25 ) PNP NPN OFF 80 mA 30 V(NPN ) () 1.5 V (80 mA ) 1 1.5ms (060 s/0.01 ) 2 0 3 MPakPakgf/cm 2barpsi LCD 3 (X2) / 4 (7 ) 4 (1 11 7 ) ON OUT1OUT2
Display/Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa -0.105 to 2.100 MPa Display/Min. setting unit 0.1 kPa 0.001 MPa Proof pressure 500 kPa 2 MPa 4 MPa Power supply Power supply voltage 12 to 24 VDC10%, ripple max. 10% (p-p) spec.
Indicator light With Special function Applicable load Electrical entry Wiring (Output) Type 0.5 () 3 (L) Perpendicular In-line DC AC 3-wire (NPN) Solid state switch F9NV F9N P P 5V 12V IC _ _ Relay, PLC Grommet 3-wire (NPN) 24V F9PV F9P P P 2-wire 12V F9BV F9B P P Lead wire length: 0.5m.
hole) 20 12 23 15 1/8,1/4 (P , R port) 48 1797
Then, the charging time (T) for a 100 l tank, T = t x = 49 x = 49 (s). V 10 10 10 T = t x = 110 x = 110 (s). V 10 10 10 T = t x = 2.4 x = 24 (s).
Contact P/A when using the regulator between a solenoid valve and an actuator.
1090 2 -67No.PF-OMM0004-D (PVC ) PF3W711 PF3W721 (3 mPas(3 cP)) 1 10100 L/min 30250 L/min 7140 L/min(7 L/min 0) 20350 L/min(20 L/min 0) 7140 L/min 20350 L/min 1 L/min 2 L/min (50 ms) 1 L/pulse 070 () L/minL 3F.S. 3F.S. 2F.S. 2 5%F.S.(25 ) 3 3 9 L 4 1L NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 25 0.5 s/1 s/2 s 6 0.5 s/1 s/2 s 15 V 1 k 420 mA DC12 V 300
Nil s n A B 16.5mm 19.5mm 40, 50, 63 50, 63 40 bore size is only available with A:16.5mm clevis width. Auto switch type Nil CLK1P Without auto switch (built-in magnet) with switch rail Bore size P CLK1G 40 50 63 40mm 50mm 63mm Select applicable auto switch models from the table below. Built-in magnet cylinder part nos.
Internal circuit and wiring example Z/ISE40A(F)Output specification -S/-R (Analogue output mode) Switch output NPN open collector output type-2 output Max. 28 V, 80 mA Residual voltage 1 V or less R: Analogue output 1 to 5 V Output impedance 1 k S: Analogue output 4 to 20 mA Max. load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Min. load impedance 50 -S/-R (
Pilot port Tightness of Valve (Leak rate) Fluid Seal material (2) Air Non-leak, Vacuum Liquid NBR, FKM, EPDM 106Pam3/s or less (1) 1 cm3/min or less 0.1 cm3/min or less Note 1) Differs depending on the operating conditions such as pressure, etc. Note 2) Value on option V, M (Non-leak, Vacuum). Port A Port P Pilot Pressure Port P (N.O.)
Example) -DNS All S kits are DIN rail mounting styles, so include suffix D. Specify the wring specifications in the manifold specification sheet. (Except L kit) F, P and S kits are provided with an exhaust on one side, while L kits are with an exhaust on both sides. Note 1) 01 1 station Note 2) The number of max. stations differs from kit to kit. (Refer to the table below.)
when the solenoid valve is turned ON and closes when it is turned OFF. 10 XL-OMV0016 5-2.Dimensions C (KF flange) (K flange) Fd Fn C J Port 1(P) S K L M N B T Port 3(R) A G A Unit: mm Model A B C Fn Fd G J XLAV-16-2 40 108 38 30 17 41 XLAV-25-2 50 121 48 40 26 46 XLAV-40-2 65 171 66 55 41 54.5 XLAV-50-2 70 185 79 75 52 61 XLAV-63-2 88 212 100 87 95 70 80.5 XLAV-80-2 90 257 117 114 110 83
A A afll-'h s-zl;lh P R P R (external pilot type) A A , A;Tt-Zb gzt;]ri! , P R P R Model Specifications Air and inert 20-100 PSI (1.5"7kgf/cm,) VAC-1 10Torr 20-1OoPS|(15-7ksflcm'?) N,lax. 120'F (50'C) 20 ms or less (7OPS|) 600 cpm , Slotted Knob locking type Individual, Common Not (Use turbine oil # 1 (lSO VG32) if lubrication is Drovided.)
A A afll-'h s-zl;lh P R P R (external pilot type) A A , A;Tt-Zb gzt;]ri! , P R P R Model Specifications Air and inert 20-100 PSI (1.5"7kgf/cm,) VAC-1 10Torr 20-1OoPS|(15-7ksflcm'?) N,lax. 120'F (50'C) 20 ms or less (7OPS|) 600 cpm , Slotted Knob locking type Individual, Common Not (Use turbine oil # 1 (lSO VG32) if lubrication is Drovided.)
cm3 Note 3) for 0.5MPa 31 61 220 390 680 1420 Solenoid valve SYJ319 SYJ519 Port size M5: Port1(P), 3(R) Rc1/8: Port1(P), M5: Port3(R) Weight kg 0.34 0.54 1.3 1.9 3.3 5.8 Note 1) Conductance is molecular flow measured with an elbow pipe which has the same dimension as each applicable flange.
CH kPa MPa kPa MPa MPa kPa kPa MPa kPa MPa OUT1 OUT2 CH 1 2 3 4 P R E S S U R E Copy function (page 14) Each channel's information can be copied to another channel.
P Panel mount union U Union Ordering Example OUT side Tube size 4 x 3 LQ1U22-S Union SMC PB1313AS-1S07 Process pump PB1313AS-1S07 1 LQ1E21-S (Union elbow) 1 LQ1U22-S (Union) 1 LQ1E21-S Union elbow Tube size 6 x 4 Note) Fittings ordered together with the process pump will be shipped in a separate package.