SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-X-M-M5-WD"

Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: 0.00 to -14.69 psi, Piping: M5 x 0.8, Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -

Piping: M5 x 0.8, Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Specifications AP3260 Select compatible materials of construction for the gas Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 40 to 194F (40 to 90C) (No freezing) 0.27 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 1) 1 x 10-7 Pam3/sec 1) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld Bottom mount (Option: panel mount) 0.06

Weight (g) LEC S LEC SS-T D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 LEC Y 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 Motorless 5 m (Z) 68 63 LAT Dimensions LZ (mm) D-M9 D-M9V LC3F2 M2.5 x 4 L M2.5 x 4 L Indicator light Slotted set screw Slotted set screw 8 Indicator light 2 3.2 4.6 2.6 4 2.8 2.7 2.7 20 2.8 4 22 3.2 2.6 9.5 Most sensitive position 6 4 6 Most sensitive

Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x

Table 1 Display Real-time flow rate l/min Accumulated flow l, m, m x 10 ft, ft x 10, ft x 10 CFM Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10)]. 14 For Air Digital Flow Switch Series PFA 4. Output Specification Selection Mode For For Flow rate setting SET SET Press the SET button.

Pin description PF2A7H-(-M) 68 69 1 DC(+) 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30V 80mA or less OUT1 Black Load H 0V Blue 50msec PF2A7H-(-M) 28 29 B C D E F G H I J A Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc

Pin description PF2A7H-(-M) 68 69 1 DC(+) 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30V 80mA or less OUT1 Black Load H 0V Blue 50msec PF2A7H-(-M) 28 29 B C D E F G H I J A Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc

Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).