Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: ST (S + T), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: SV (S + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: BDG (B + D + G), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 03 (3/8), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 6R (6 + R), Semi-Standard 2: Standard
Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 0.5 40 8 0.5 Gripping force (N) Gripping force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Gripping point L (mm) 40 0 30 40 60 70 Gripping point L (mm) 50 80 MHY2-16D MHY2-25D F F F F 35 100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 Gripping force (N) Gripping force (N) 25 External grip 0.4 0.4
Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 0.5 40 8 0.5 Gripping force (N) Gripping force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Gripping point L (mm) 40 0 30 40 60 70 Gripping point L (mm) 50 80 MHY2-16D MHY2-25D F F F F 35 100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 Gripping force (N) Gripping force (N) 25 External grip 0.4 0.4
R R L L L R Standard piping/Centralized piping (mm) L R WXX Y S d D R Applicable O-ring Model Operating direction Centralized piping MY1B25 MY1B32 MY1B40 15.5 16.2 5.5 6 11.4 1.1 C9 20 20.4 5.5 6 11.4 1.1 L R 23.5 25.9 6 8 13.4 1.1 C11.2 DO-ring R R R Centralized piping (mm) R R R L L L WX SS Model L -X MY1B25 MY1B32 MY1B40 R R 26.5 10 Centralized piping Piping tube 40 5.5 Note) Refer to
MDHR2-10/15 MDHR2-20/30 D20H H L L Auto switch of D-M9 is used. When auto switch D-M9V is used. Auto switch of D-M9V is used. (mm) Max. Protrusion of Auto Switch from Edge of Body: H Max.
7 20 20 L (mm) L K J V H S Z M MA W Model 36 40 93 82 58 20 102 40 30 65 MXP16-20B 42 50 119 108 70 30 128 56 46 75 MXP16-30B 14
(F: Thrust of one finger) Pressure 0.6MPa 0.5 40 8 0.5 Holding force (N) Holding force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Holding point L (mm) 40 0 30 40 60 70 Holding point L (mm) 50 80 F F F F MHY2-16D MHY2-25D 35 100 Pressure 0.6MPa Pressure 0.6MPa 30 0.5 0.5 80 25 External hold Holding force (N) Holding force (N) 0.4 0.4 60 20 0.3 0.3 15 40 0.2 0.2 10 20
IEC529 Standard IP67 watertight (JISCO920) For a lead wire length of 3m, "L" is added at the end of the part number. Example) D-F9NL Main switch circuit Main switch circuit Output Black [White] () Blue [Black] D-F9P (+) Brown [Red] Auto Switch Dimensions (mm) 1in=25.4mm Output Black [White] D-F9N, D-F9P, D-F9B () Blue [Black] D-F9B (+) Brown [Red] L dimension (mm) Part No.
Standard piping type Centralized piping type Operating direction Operating direction Side Front Side Front L R L R L L L R L R R R R R R R L L L L L R L L L Back New Back R R R Bottom Bottom Port variation Port variation R and L can be mounted in any desired position.
How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end nut C1 X L1 Rod End Male Thread (mm) Bore size (mm) 63 Auto switch D-A9, F9 C1 X H1 L1 26 28.5 M18 x 1.5 33.5 80 32.5 35.5 M22 x 1.5 43.5 100 32.5 35.5 M26 x 1.5 43.5 (mm) Without auto switchWith auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P
min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility water flow rate [L/min] Facility water flow rate
ZL1 Series RoHS How to Order ZL 1 12A Without valve ZL 1 5 M Z D A M L 12A K1 With valve Max. suction flow rate: 100 L/min (ANR) q w t o u i e r y !0 !1 !
C A D Model D C Model D C Mounting bolt (mm) Mounting bolt (mm) M18 x 125 l M18 x 135 l 125 135 C (D) Q2B18010DC C (D) Q2B20010DC M18 x 135 l M18 x 145 l 135 145 C (D) Q2B18020DC C (D) Q2B20020DC M18 x 145 l M18 x 155 l 145 155 C (D) Q2B18030DC C (D) Q2B20030DC M18 x 155 l M18 x 165 l 36 155 39 165 C (D) Q2B18040DC C (D) Q2B20040DC M18 x 165 l M18 x 175 l 165 175 C (D) Q2B18050DC C (D) Q2B20050DC
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 314 283 251 220 188 157 126 94 63 314 OUT 20 10 236 212 189 165 142 118 94 71 47