SMC Corporation of America
Elite Part Number Search
Search Results "CNGLN40-800-D"

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 (5/8"), Stroke: 800 (8"), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 0.5M

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: N (NPT), Port Size: 14 (1+1/2), Option 1: 2 (Metal Bowl), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: N (NPT), Port Size: 14 (1+1/2), Option 1: 6 (Nylon Bowl), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: N (NPT), Port Size: 14 (1+1/2), Option 1: 8 (Metal Bowl w/Level Gauge), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: Rc (PT), Port Size: 14 (1+1/2), Option 1: 2 (Metal Bowl), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: Rc (PT), Port Size: 14 (1+1/2), Option 1: 8 (Metal Bowl w/Level Gauge), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: N (NPT), Port Size: 14 (1+1/2), Option 1: None, Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: Rc (PT), Port Size: 14 (1+1/2), Option 1: 6 (Nylon Bowl), Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: Rc (PT), Port Size: 14 (1+1/2), Option 1: None, Option 2: D (Drain Cock for Thread Piping)

Size: 8 (Size 800 Port Size 1-1/4,1-1/2 Flow 9000Nl/min), Auto Drain: 00 (None), Thread: F (G(PF)), Port Size: 14 (1+1/2), Option 1: 2 (Metal Bowl), Option 2: D (Drain Cock for Thread Piping)

IDFA Series 6-1 Specifications 6 1 IDX-OM-W031 Air Dryer 6 References 6-3 Dimensions IDFA22EIDFA37E IDFA55EIDFA75E Measuremm Model Port Size A B C D E F G K L M N P Q R IDFA22E R1 290 775 623 134 405 698 93 13 314 85 600 340 IDFA37E R1-1/2 855 680 IDFA55E R2 470 855 800 (128) (273) (868) (110) 13 500 75 700 526 (110) 519 IDFA75E 900 (968) IDFA Series 6-3 Dimensions 6 2 IDX-OM-W031 Air Dryer

Before restarting the equipment, confirm that measures are taken to prevent sudden action. 7 (5) Make sure to wear safety goggles for regular maintenance. (6) Please check the following points, and replace the parts as necessary. a) Scratches, damage, wear, or corrosion b) Air leakage c) Squeezing, kinking or twisting of the tubing d) Hardening, deterioration or softening of the tubing (7

D The setting time from when the pressure applied to the pressure switch reaches the set value, to when the ON-OFF output actually begins working. Delay time setting can prevent the output from chattering. Delay time Shows how precisely the pressure can be displayed or set by the digital pressure switch.

This is a legacy product, and replaced byCDNA2F100TN-800-D

For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500

Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors.

Style: HT (Double Axis Type), Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 800, Motor Option: w/o Option, Actuator Cable Type: R (Robotic Cable, Flexible), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: D (DIN Rail Mounting)

Style: H (Single Axis Type), Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 800, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 3 (3m), Controller Mounting: D (DIN Rail Mounting)

Style: H (Single Axis Type), Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 800, Motor Option: w/o Option, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 2P [LECP2, Programless Type (w/Stroke Study), PNP], I/O Cable Length for LEC: 5 (5m), Controller Mounting: D (DIN Rail Mounting)

Avoid using in a place where condensation occurs due to a drastic temperature change. d. Avoid using in a place in the presence of corrosive or explosive gas or where there is a volatile combustible. e. Avoid using in an atmosphere where there are particles, conductive iron powders, oil mist, salt, solvent, blown dust, cutting oil (water, liquid), etc. f.