Bore Size: 25mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: G (Centralized Piping), Stroke: 800mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 32mm, Port Thread: TN (NPT), Piping: Standard, Stroke: 800mm, Stroke Adjusting Unit: w/o Adjustment Unit, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 40mm, Port Thread: M Thread (ø16) Rc Threads (ø25, ø40), Stroke: 800mm, Stroke Adjustment Unit: Left, Right Side w/o Adjustment Unit, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 16mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 800mm, Stroke Adjusting Unit: w/o Adjustment Unit, End Lock: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 25mm, Port Thread: G Thread, Stroke: 800mm, Stroke Adjusting Unit: w/o Adjusting Unit, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-In, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 40mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 800mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number

Magnet: Built-in, Mounting: Basic, Bore Size: 125mm, Port Thread: Rc, Stroke: 800mm, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: 140mm, Port Thread: Rc, Stroke: 800mm, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Foot, Bore Size: 160mm, Port Thread: Rc, Stroke: 800mm, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-In, Mounting: Axial Foot, Style: Non-lube Rubber Bumper, Bore Size: 40mm, Thread: NPT, [ø20 to ø100 Rubber Bumper, ø32 to ø100 Air Cushion, Piping: Screw-in Piping, Stroke: 800mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, X

Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 160mm, Thread: NPT, Stroke: 800mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Lock

Option NIL Without photoelectric sensor *1 NIL Without option S Photoelectric sensor *2 D With 2 three meter length exhaust duct hoses with 2 hose bands attached *1: Connect a switch to the external input terminal on the back side of the product. P With 2 dust bags with 2 hose bands attached *2: This is a regression reflection type photoelectric sensor.

Dimensions E C D E E L (Width across flats) M (Width across flats) M8 (KF Flange) (K Flange) Fn Fd C Detail of (a) (a) M Rc1/8 J H K B A G A Model A B C D E Fn Fd XLGR-80*-1* 90 250 117 45.5 38.5 114 110 XLGR-100*-1* 108 270.5 154 55 38.5 130 102 XLGR-160*-1* 138 339 200 65 38.5 180 153 Model G H J K L M XLGR-80*-1* 83 105 44 9 13 4 XLGR-100*-1* 102 92 58 9 13 4 XLGR-160*-1* 153 124 62 12.5

D) In the state of C), adjust shim so that the arm side block contacts the workpiece. E) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 7 - Relation between shim thickness and clamping force 3 Use this figure as a guide as there is a tolerance of about 10% in the clamp cylinder body.

FRANKLIN ROAD INDIANAPOLIS INDIANA 46226 PHONE: 317-899-4440 FAX: 317-899-3102 TOLL FREE: 1-800-SMC-SMC1 1978-2000 SMC Pneumatics, Inc. All Rights Reserved. JB

Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Supply pressure MPa 0.9 0.9 0.9 0.7 0.8 0.9 0.6 0.7 0.8 0.9 0.9 Valve output pressure (MPa) Valve output pressure (MPa) Valve output pressure (MPa) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.6 0.1 0.2 0.3 0.4 0.5 0.5 0.1 0.2 0.3 0.4 4000 6000 2000 200 400 600 800

ii'lri-tr'i"d'..r..t to the inside. Panel mount bracket Phillips type screwonver Removing Tube Installing Tube OPush in evenly on the release button. (DCul the tube perpendicularly, being caretul not to damage the oulside sulace, use tube culler TKA-1.