Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, TIE ROD CYLINDER, MB, TIE ROD CYLINDER, 0.00000 lb
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 1500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto
Magnet: Built-in, Style: Air Pressure Style, Mounting: Single Clevis, Bore Size: 32mm, Piping: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Port Location Changed
Magnet: Built-in, Style: Air Pressure Style, Mounting: Integral Clevis, Bore Size: 25mm, Piping: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Port Location Changed
Magnet: Built-in, Style: Air Pressure Style, Mounting: Integral Clevis, Bore Size: 32mm, Piping: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A34A--Reed, DC Volt >5 <24, AC Volt <200, LED, Terminal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Options: Port
Magnet: Built-in, Style: Air Pressure Style, Mounting: Double Clevis, Bore Size: 25mm, Piping: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Port Location Changed
Magnet: Built-in, Style: Air Pressure Style, Mounting: Double Clevis, Bore Size: 40mm, Piping: Rc, Stroke: 150mm, Cushion: Rubber Bumper, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Options: Port Location Changed
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches