View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.
Fig. 6 26 - Calculation formulae for moment of inertia I: Moment of inertia [ kgm ] m: Load mass [ kg ] 2 1. Thin shaft 6. Thin round plate Position of rotational axis: Through the center of Position of rotational axis: Perpendicular to the shaft through the center of gravity diameter r a 2 a 2 r I = m I = m4 12 2. Thin rectangular plate 7.
8-23-12 13 Guide Table Series MGF Operating Range Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch model Bore size (mm) 40 63 100 10 10 10 D-Z7/Z80 D-Y59, D-Y69 D-Y7P/Y7PV D-Y7W/Y-7WV 6 6 6 B A 5 5 5 D-Y7BAL Since this is a guideline including hysteresis, not meant to be guaranteed.
: 0.12 10% or less 3% or less 1MPa 12, 24VDC 0 to 2W 0 to 4W Class B Series PVQ How to Order P V Q 13 5 L 03 M5 Valve type Body materials Symbol A Nil Body Brass C37 Note for PVQ13 for PVQ31, 33 13 31 33 N.C.
69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".
port Rc1/8 Dimensions/With DIN rail Station L1 L2 L3 2 70 105 140 3 105 140 175 4 140 175 210 5 175 210 245 6 210 245 280 3.8-6 ISA Guide for Use/Design Data When designing a pneumatic circuit with an Air-Catch Sensor, please refer to the data below.
. i-4 i-2-7 . i-4 i-2-8 . i-5 i-2-9 . i-5 i-3 . i-6 i-4 / . i-7 1 1-1 . 1-1 2-1 . 2-1 2-2 . 2-1 2-2-1 . 2-1 2-2-2 . 2-2 2-2-3 . 2-2 2-2-4 . 2-2 2-2-5 . 2-3 2-3 . 2-4 3 / 3-1 . 3-1 3-2 . 3-1 3-3 . 3-2 3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 . 4-1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 5-2 . 5-3 1 6 6-1 . 6-1 6-2 GWP . 6-1 6-3 . 6-2 6-
3 b b Nm a Nm 1 2 4 XLD-25 1.5 0.3 -40 2.5 -50 6 -63 6 -80 15 -100 20 -160 102 a M M0.2MPa b b O a 19 XL-OMY0002 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2020 SMC Corporation
load weight 30kg and 100mm eccentric distance From Graph 6, the cylinder can be used at a maximum speed of 100mm/s or less. 12 Series MGF Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
ECC-PNAL-20MT-D ECC-PNAL-20MR-D ECC-PNAL-20MR-A ECC-PNAL-10MT-D ECC-PNAL-10MR-D ECC-PNAL-10MR-A ECC-PNAL-6MR-A Please Note: 1) All PneuAlphas need to be connected to a power supply. 4/2 : 6/4 : 12/8 suitable to their rated voltage specifications. 2) Stand alone controllers can be programmed from the 8 front panel function keys. 3) All Pneu Alpha controllers have a CD-ROM supplied giving
Applied voltage When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause malfunction or coil damage. M5 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/6 to 1/4 turn. As a reference value, tightening torque is 1 to 1.5 Nm.
Also, it may cause danger. 10 XL-OMO0001-A 6-2. Disassembly procedure Step 1 Step 2 3 Bolt b O-ring 1 2 4 Bottom surface of the groove to discharge gas. Bonnet assembly Heater Bolt a Cover Body The heater is removed by loosening bolt a. Bolt a is behind the cover. Remove the cover using a watchmaker's screwdriver.
M5 After tightening by hand, tighten additional 1/6 to 1/4 rotation with a tightening tool Tapered thread for Rc port (MGP) and NPT port (MGPTN) Use the correct tightening torques listed below. Before tightening the plug, wrap pipe tape around it.
119 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1 2 2-Rc 3 4 2-Rc1 Model J K L M N O P Q R S T U V VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth 6 M8 x 1.25 depth 6 M8 x 1.25 depth 6 202.5 232 267 286.5 29 36 48 51 25 30 35 38 30 40 50 56 37 43 50.5 58.5 75 100 126 141 88 118 148 163 34 44.5 60.5 66.5 10.5 16 19.5 15.5 62 6 x 8 7 x 10 9 x 12 9 x 12 20
mounting hole 40 8.5 20 28 72.5 (when set = 75.5) Bleed exhaust hole 6.5 28 41 1.6 Port size A B IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3
Flow Rate and Sonic conductance AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 0.28 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 8 1/4" 5/16" 460 1.3 6 10, 12 8 6 6 10 2 Flow Direction Symbol on Body Tube O.D.
Sound absorbing material A 1 9 PVF Suction cover P397114 Sound absorbing material 2 10 PVF Front cover A P397230 O-ring 3 11 NBR End plate 2.79 x 1.02 (NZL) When ordering a vacuum pressure gauge or a digital vacuum pressure switch separately, use the part numbers shown in the option specifications on pages 5 & 6. 4 Body 5 Vacuum sensor unit 6 Nozzle 7 Diffuser Other than vacuum switch P397110
2-4.4 Mounting hole EJECTOR MULTISTAGE 76 52 8 178.5 5 4.5 (40) Section A/ With Digital Vacuum Pressure Switch ZL212-E (ZSE4) ZL212-EB (ZSE4B) ZL212-EE (ZSE4E) 27 (2) (1.6) 4-M5 x 0.8 Thread depth 6 (Mounting hole) 73 87 13-7-12
VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262 0-04 only) 2-M5 x 0.8 depth 8 Dimension of view from A Pilot port Port size P Rc , With bracket E Port size View from A Model A B C D VXA22 52 60 02 03 VXA226 -04 2 0 1 4 3 8 22 28 11 14.5 67 73 77 83 27 30 1 2 Fixing with thread is also possible