SMC Corporation of America
Elite Part Number Search
Search Results "10-SS5YJ3-32-02-M5"

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: R (Flow Direction: Right to Left)

Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge

Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. drop 4 High circulating fluid return temp. 5 High circulating

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 14 Stations, A B Port Size: N3T (5/32" One-touch Fitting NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 13 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

The series is available in base mounted or body ported styles.Bar stock type manifold for SYJ3000 valves, Supply and exhaust ports common (20, 31, 32, 41 types), Valves individually wired, Maximum 20 stations available as standard, 5 port sizes available, SYJ 5 port valve manifold, SYJ, 4/5 PORT SOLENOID VALVE, 0.00000 lb

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 9 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 11 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 18 Stations, A B Port Size: C4 (ø4 One-touch Fitting)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 3 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: N (NPT)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 4 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: F (G)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 5 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: N (NPT)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 6 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: N (NPT)

Valve Mounting Direction: Solenoid on the Side Opposite to A,B Ports, Piping: 32 (4 Port/Base Mounted Common SUP Common EXH), Stations: 7 Stations, A B Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: N (NPT)