Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.
Process Pump (Diaphragm Pump) PB Series Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids Compact, large capacity diaphragm pump, suitable for transferring and collecting a wide range of fluids o t p m s l a i PA z P e Built-in solenoid valve only RoHS Smaller, lighter, 25% reduction in volume Smaller, lighter, 25% reduction in volume
Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.
Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.
() CE 0~50 -8No.PF-OMJ0005CN-I * 3 (20 ) LED * OUT * 23% -9No.PF-OMJ0005CN-I 7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02
Available N02 (1/4 NPT), N03 (3/8 NPT) and N04 (1/2 NPT) Metal bowl available as option (-2) Series SL Slimline Auto Drain and Filterstop SPECIFICATIONS Timer Solid-state construction Status Indication Power ON / Valve OPEN Interval Time 0.5 to 45 minutes (as required) Discharge Time 0.5 to 10 seconds (as required) Electrical Connection DIN 46242 LED indicators show operational status
This is a legacy product, and replaced byZH13DSA-N01-N02-N02, VACUUM EJECTOR, 1/8 SUP, VACUUM SERIES, ZH VACUUM EJECTOR, DD, ZH NOZZLE SIZE 1.3, .11660 lb
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4)
Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N01 (Screw-in NPT 1/8), VAC: N02 (Screw-in NPT 1/4), EXH: N02 (Screw-in NPT 1/4)
This is a legacy product, and replaced byZH13DSA-N01-N02-N02, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .08250 lb
9 Diaphragm (Material: Stainless steel 304) u Valve seat (Material: FKM) y External seal (Material: FKM) e Bellows (Material: Stainless steel 316L) !
X Y X Y LS Full stroke LG CX LZ LX 4-LD 32 57 57 71 11.2 5.8 A + Full stroke 40 64 64 78 11.2 7 CY 50 79 78 95 14.7 8 63 95 113 16.2 9 91.5 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC Front flange style: RZQF MK(2) RS Q G Flange Style (mm) FV M Bore
l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx
This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD
(Refer to p.1.1-6 for further information on specifications.) Ass'y part No.
Real-time switch output Unit switching Hysteresis mode ON YES Display Real-time flow rate Accumulated flow OFF P-1 P-2 L/min L Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (L/min, L, m3 or m3x10) will be set for the type without the unit switching function.
Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R
O-