SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-R-M-N02L-E"

Barrel Perfluoro R is a registered trademark of MATSUMURA OIL Co.,Ltd. Kalrez R is a registered trademark of E. I. du Pont de Nemours and Company. Chemraz R is a registered trademark of Greene, Tweed & Co., ULTIC ARMOR R is a registered trademark of NIPPON VALQUA INDUSTRIES, LTD.

steel J D I G F E C Thread B A Barb one-touch: M-32F-2, M-04F-2 Applicable tubing (mm) a (O.D. x I.D.) b (O.D.) 3.2 4 2 x 1 .2 Weight g B C D E M A Model M-32F-2 M-04F-2 17.7 18 1 3.7 14 7.5 8.5 2.4 2.9 4 0.9 12.7 Parts list 4 3 2 1 E Material Brass Brass NBR No. 1 2 3 4 Description Sleeve Body Seal Cassette Note Electroless nickel plated Electroless nickel plated D C POM, Stainless steel

2 w y r !0 e PF2A Number Parts Material 1 New PFA Body PF3W 2 New PFA Sensor 3 Super PFA Tube LFE 4 PPS Housing A 5 PPS Housing B PF2D PF2D 6 PPS Housing C 7 POM Bushing IF 8 PPS Cap 9 FKM Gasket !1 q t i 10 FKM O-ring PF2D540 o !0 u !0 !2ywr e 11 Stainless steel 304 Thread 12 PVC Lead wire !

The same applies to the guide shaft. e Make sure not to apply shocks or excessive moment to the slide block of the ball bushing style. r The port direction of the actuating cylinder can be changed in 90 increments by removing the four bolts that secure the cylinder in place.

N M N M M N Q L K J H F E D C B A P Applicable thread Pc Normally open Normally closed VXP2270 VXP2380 VXP2390 VXP2272 1 43.5 46.5 52 51.5 54.5 59 53 60 71 67.5 72 81 48 50 50 95 97 97 62 64 64 125 132 150 128 (145) 144 (159) 160 (175) 26.5 30 35.5 57.5 60 69 23 25.5 25.5 35 40 40 92 (102) 103 (113) 114 (124) 25.5 28 28 84 (94 ) 95 (105) 106 (117 ) 41.5 84 (94) 95(105) 106(117) 60 62 62 84

Discharge Q B ZM Drain guide (-J) ZH ZU Maintenance space 40 R ZL P Rc 1/8 Drain 1/4 female thread without valve function ZY Hexagon width across flats 24 ZQ AMJ5000 L A F ZF Bracket (Option) G K M ZP D J C E ZCU OUT IN AMJ Misc. 2port size Q B Maintenance space 20 Rc 1/8 Drain (mm) A B Note) C D With drain guide R Note) Bracket mounting dimensions Model Port size Q E F G H J K L M 169 (

Pressure gauge unit 2) e 2P 3P 4PL r t Sample Order Number Port Unit psig/bar MPa Code qIN wOUT eExtra bottom port (Outlet) rGauge port (Inlet) tGauge port (Outlet) AK1202S e q 8 8 8 8 w 8 8 8 8 r r No code MPA q w 2P 3P 4PL 5PC MPA MPA MPA V3 V3 V3 2) Pressure gauge unit MPa or psig/bar selectable.

Air operated style fluid control valve Vacuum valve Vacuum pad 2(A) 1(P) 2(A) 1(P) 2(A) 1(P) 2(A) 3(P) 3(R) 3(R) 3(R) 1(R) Atmospheric air or micro pressure for vacuum release 22 Multi-purpose Valve Series VCA Direct Operated 2 Port Solenoid Valve for Air Improved durability (Nearly twice the life of the previous series) Operating resistance of moving parts reduced for improved longevity

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Rc1/8, Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -

wire and case) 10 to 60C Ambient temperature Enclosure IEC60529 standard IP67 Lead Wire Lead wire length indication (Example) D-M9BW L Lead wire length Nil M L Z 0.5 m 1 m 3 m 5 m Note 1) 1 m (M): Available D-M9(V) only The D-M9M and M9VM (lead wire length: 1 m) will be available with products delivered from August 2008 onwards.

L R L R L R L R L R L R Glass q w e Stainless steel Stainless steel Cross recessed round head screw Brass Stainless steel r t Stub 3.8-2 ISA Specifications Fluid Dry air (Filtered through a 5m filter) Operating pressure range 0.05 to 0.2MPa Recommended pressure range 0.1 to 0.2MPa Detection zone 10 to 300 m Repeatability including temperature characteristics 10m (for 0 to 60C on the basis

7 r !9 w !4 NCY3B6 NCY3B10, 15 !4 !8 !7 !6 !5 !0 i o q u y t r !2 w !1 The above drawing is 15. (3 magnets are used in 10.) NCY3B20 to 40 !3 !4 !1 !8 !6 !5 !7 !0 i q o u t y r e w !2 NCY3B50, 63 !4 !8 !6 !5 !0 !7 i o q u y t !3 r !2 w !1 Component Parts No.