B 0 Normally Closed/Single unit Electrical option Nil None Port size S With surge voltage suppressor L With indicator light 02 03 04 Rc 1/4 Rc 3/8 Rc 1/2 With light/surge voltage suppressor Z Refer to the table (1) given below for availability.
Mesh: 100/70/50/25 mesh How to Order WF300 02 Port size Mesh 02 Rc1/4 03 Rc3/8 04 Rc1/2 Nil 100 mesh 1-X204 70 mesh 2-X204 50 mesh 3-X204 25 mesh Related Equipment Check Valve INA-14-290/XTO-674Water Regulator WR110--X224/WR110--X215 Body material: Brass Body material: Special brass Best Pneumatics 14-E627 Port size Set pressure range (-X224): 0.08 to 0.39 MPa Rc1/8, Rc1/4 Set pressure
Applicable bore size (mm) B C D d H Dd9 L d Part no. 0.040 0.076 0.040 0.076 0.050 0.093 14 0.050 0.093 0.040 0.076 0.040 0.076 0.040 0.076 CD-G02 CD-G25 CD-G03 CD-G04 NT-02 NT-03 NT-G04 20 25 32 40 20 25, 32 40 21 25.6 41.6 7.6 9.6 9.6 IY-G02 IY-G03 IY-G04 M8 x 1.25 5 6 8 20 25, 32 40 13 17 19 15.0 19.6 21.9 12.5 16.5 18 8 10 12 8 10 10 43.4 48 59.4 71.4 7.6 9.6 11.5 13.4 M10 x 1.25 M14
IY-G02 IY-G03 IY-G04 Type C 8 for axis Type C 10 for axis Type C 10 for axis NT-02 NT-03 NT-G04 CD-G02 CD-G25 CD-G03 CD-G04 0.040 0.076 8 Type C 8 for axis Type C 10 for axis Type C 12 for axis Type C 14 for axis 0.9 1.5 20 25, 32 40 21 7.6 9.6 9.6 16.2 13 17 19 20 25, 32 40 (15) 12.5 16.5 18 M8 x 1.25 5 6 8 0.040 0.076 8 0.9 1.5 38.6 7.6 20 25 32 40 43.4 0.040 0.076 10 0.040 0.076 10 1.15
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, INLINE TYPE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .50080 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, NZX MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .65120 lb
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb
2000 [mm] 03 3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.
03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work Line name communication data -95No.PS-OMW0012-C Maintenance How to reset the product after a
03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -88No.PF-OMZ0002-A Troubleshooting If an operation failure
03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure
set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode (Refer to page 13) 22 Option display Line name, not displayed -83No.PF-OMX0002-B [Line name communication data] Value (16 hex 00 01 02
03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 7seg Display letter 11seg Value (16 Hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7seg Display letter 11seg Value (16 Hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 7seg Display letter 11seg Supplementary information : Do not work [Toggle output command] Value Item Remarks CH1 0 1 CH2 Measurement value 2 CH3 3 CH4 CH1_OUT1
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
2000 [mm] 03 3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.
2000 [mm] 03 3000 [mm] 05 5000 [mm] 10 10 [mm] Item Specifications Connector M12 Straight RJ45 Cable O.D. 6.4 mm Nominal cross section AWG26 Min. bending radius (Fixed) 26 mm (4) Seal cap Part number: EX9-AWTS This cap is used to protect the M12 connector opening when the connector is not used.
Option/Semi-standard symbol : When more than one specification is inqures, indicate in alphanumeric order. 3 4 5 6 2 1 Symbol Description 0 0.01 to 0.2MPa 1 0.01 to 0.4MPa Set pressure range 2 0.01 to 0.8MPa + 0 Bottom exhaust 1 Front exhaust Exhaust direction 2 Back exhaust + Nil Rc N NPT Thread type F G + 02 1/4 03 3/8 Port size 04 1/2 + Nil Without mounting accessories B With bracket