Rated Pressure Range: 1 to -101 kPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: W/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket:
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: E (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAN. ASSY ISO #1, VALVE, VV7* BASE MT 3/8, 2.97624 lb
SMCs VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
SMCs VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
SMCs VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, ISO SIZE 1, VALVE, VV7* MANIFOLD ISO SERIES, PL, VV7* BASE MT 1/4, 2.26298 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, ISO SIZE 1, VALVE, VV7* MANIFOLD ISO SERIES, PL, VV7* BASE MT 1/4, 7.49571 lb
SMC's VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
SMC's VQ7-6/7-8 series valve conforms to ISO standard 5591/I. A choice of metal or rubber seal increases compatibility with various operating and environmental conditions. Manifolds are available with a wide range of interface options to meet a variety of application requirements. The VQ7-6/7-8 has a smaller, space-saving profile and is lighter in weight than the VS7/VP7 series. Manifold
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: None, Option 3: Operating Manual Booklet, X Options: Lead Wire Length 3m