8 to 400 30 to 1200 20 to 850 10 to 300 401to 500 10 to 600 5 to 300 20 to 1100 12 to 750 6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 501 to 600 20 to 900 12 to 540 6 to 270 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 601 to 700 20 to 630 12 to 420 6 to 230 24 to 930 16 to 620 8 to 310 30 to 1200 20 to 850 10 to 300 In-line Stroke 701 to 800 20
With front lockR (mm) Bore size (mm) W P WA WB WH 20 M5 x 0.8 16 15 (16) 23 30 25 M5 x 0.8 16 15 (16) 25 30 32 Rc1/8 16 15 (16) 28.5 25 40 Rc1/8 16 15 (16) 33 20 50 Rc1/4 18 17 (18) 40.5 20 63 Rc1/4 18 17 (18) 47.5 20 80 Rc3/8 22 22 60.5 20 100 Rc1/2 22 22 71 20 Dimensions inside ( ) are for long strokes.
---M5 SYJ522M---M5 A port M5 x 0.8 Type 20 SS3YJ5--20-05 -Stations Bracket P, R port thread type + + + + Nil Nil 02 : 20 Rc G NPT NPTF 2 stations : 20 stations Without bracket Applicable blanking plate assembly SYJ500-10-1A R P 00F 00N 00T With bracket F P port 1/8 R port 1/8 Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
2110 20 21Direct Operated Precision Regulator (For Special Applications) Direct Operated Precision Regulator with Backflow Function (For Special Applications) Series ARP20K to ARP40K 10 20 2110 20 21-ARP20/ARP20K 10 20 21 -ARP30/ARP30K 10 20 21 -ARP40/ARP40K 10 20 21 Description Symbol Body size 20 30 40 Nil 1 Note 4) 3 Note 4) Set pressure c 0.005 to 0.4 MPa setting 0.005 to 0.2 MPa setting
As a whole product, the fluid temperature range is specified as 0 to 90 oC. -69No.PF-OMN0012-H Characteristics graph Analogue output (Flow) (PF3W504/520/540) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 6 mA 20 mA (PF3W511) A B C Voltage output 1 V 1.4 V 5 V Current output 4 mA 5.6 mA 20 mA (PF3W521) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 5.9 mA 20 mA Rated flow
(Example): CDU20-25D Bore size 6, 10, 16, 20, 25 32 32 32 Type M5 x 0.8 Rc 1/8 NPT 1/8 G 1/8 Symbol D Double acting CU Nil TN TF CQS Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40, 50 CQ2 RQ Applicable Auto Switches/Refer to pages 1263 to 1371 for further information on auto switches.
Low output power supply detecting function Detecting the condition where power supply for output decreases less than 20 V and then informing it to CC-Link profile area. This function doesnt influence error state flag and remote READY shown on the table below.
-) 20-ARP20(K) 20-ARP30(K) 20-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G46-4-l01-X3 G46-4-l02-X3 0.4 MPa Pressure gauge G46-2-l01-X3 G46-2-l02-X3 Round type Note 2) 0.2 MPa G46-7-l01-X3 G46-7-l02-X3 0.7 MPa Clean Room Compliant, Copper-free, Fluorine-free (21-) 21-ARP20(K) 21-ARP30(K) 21-ARP40(K) Model Bracket
Piping Outside diameter 1/4" = 6.35 mm Stainless steel tube or Outside diameter 3/8" = 9.53 mm Stainless steel tube Nut Front ferrule Attached to product (2 pcs each) Rear ferrule In the event of replacing the body, a space (20 mm or longer) for extending the stainless steel tubes from the IN and OUT side will be required.
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
P16 to 17 P19 to 20 Oil mist comes from the outlet side. 1. The element installed in upstream side has reached the time for replacement. Replace the element of upstream filter and AMK element. P16 to 17 P19 to 20 Performance 2. Oil has accumulated in the inlet piping or filter drain. Discharge the drain. Replace the element of AMK.
] 10 2250 lbf [10 KN] Relief port Nil No V Yes Stroke Sensor type Symbol Stroke (Applicable model) 12 12 mm (MACM2) 20 20 mm (MACM4) 30 30 mm (MACM6) 50 50 mm (MACM10) Nil Unsupported P Port side photo sensor mounted type B Port back side photo sensor mounted type Specications Precautions Model MACM2-12 MACM4-20 MACM6-30 MACM10-50 Max. allowable load weight lbf [KN] 450 [2] 900 [4] 1350 [
--X185 Fluid passage dia.: P Without bracket Air pressure supply (P) port Thread size: Q R J K Note 1) 4 x Sa Thread depth Sb 2 x L O H I N G A M Vacuum flow Dust bag When dust bag is mounted T F E D Suction air Discharge air Suction air U C C B Hose band V (mm) A 73 B 34 C 19 D 10 E 13.2 F 16.2 G 69.8 H 31 I J 35 K 27 L 4.5 M 35 N 18 O P 13 Q Rc1/8 R 28 Sa M3 x 0.5 Sb 5 T 300 U 150 V 190
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
IDFA4E15E1 L N PE M3 6.5mm 1.25mm 2 1-1 IDFA Series 1 4 IDX-OM-W017 2 2 , 2 1 IDFA4E15E 20kg 2 2 2 2 2 1 2000m 240 050 600mm 600mm 600mm ( 600mm ) 600mm 2-1 IDFA Series 2 1 IDX-OM-W017 2 2 2 2 6 6-2 IDFA4E15E 2 2 3 50 50 2 2 4 10mm 2-2-2 IDFA Series 2 2 IDX-OM-W017 2 ( 2 2 5 6-1 IEC AC230V 30mA 5A 216AWG,3 ,812 1.25 0.1m 30m M3 1.25-3 6.5mm ()M3 0.61Nm
No.EX-OMO0007-E PRODUCT NAME SI unit for CC-Link MODEL / Series / Product Number EX180-SMJ3/5# Series Contents Safety Instructions 2 How to Order 7 Summary of Product Parts 8 Definition and terminology 8 Installation and Cabling 9 General Instructions on installation 9 Connecting cables 10 LED Display and Settings 12 Troubleshooting and Maintenance 16 Maintenance 20 Specifications 21 Table
www.stevenengineering.com I 7.24 INSTRUMENTATION ELECTRO-PNEUMATIC REGULATOR D I M E N S I O N S S E R I E S VY140 0 102 03 04 D I M E N S I O N S S E R I E S VY150 0 102 03 04 D I M E N S I O N S S E R I E S VY170 0 110 12 D I M E N S I O N S S E R I E S VY190 0 114 20 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 !