Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
switch Reed switch 12 V Relay, PLC Grommet 24 V Yes 5 V, 12 V Diagnostic indication (2-color indication) 12 V IC circuit IC circuit 3-wire A96 A96V (NPN equivalent) 5 V 12 V Yes Relay, PLC 24 V Grommet A93 A90 A93V A90V 100 V 2-wire No 100 V or less Solid state auto switches marked with are produced upon receipt of order.
34 X115 52 6 62 X116 50 4 30 46 60 64 22.5 MACM4 X114 86 90 90 72 78 32.5 50 19 32 20 33 X115 56 6 78 40 X116 54 4 40 6.6 12 19 17 18 M5 7 MACM6 X114 118 125 125 97 113 33.8 53 28 33.3 30 43 X115 59 6 98 60 X116 57 4 60 MACM10 X114 185 197 198 11 152 182 18 53.8 77 31 24 13 0 53.3 50 70 X115 83 6 108 X116 81 4 5 Centering Unit MACM Series Dimensions P: Port side photo sensor mounted
SUS304) 7 11 XL-OMV0017 5-2.Dimensions C E C E E (KF flange) (K flange) Fd Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLF-16-2 40 108 38 20 30 17 44 XLF-25-2 50 121 48 27 12 40 26 44 XLF-40-2 65 171 66 39 11 55 41 67 XLF-50-2 70 185 79 46 11 75 52 72 XLF-63-2 88 212 100 55 11 87 95 70 76 XLF-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMV0017 6.
Refer to 12. Dimensions (page 31) for necessary space. Piping Warning: 1) Before piping, perform flushing or cleaning of the piping, etc. to remove any cutting chips, cutting oil, solid foreign matter, etc. from the piping.
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
Recommended Tightening Torque [Nm] Connection thread Pressure Control Equipment 1/2 3/8 1/4 1/8 Torque 28 to 30 22 to 24 12 to 14 7 to 9 2. Avoid excessive torsional moment or bending moment other than those caused by the equipments own weight as this can cause damage. Support external piping separately. 3.
SYJA3 20 1 M3 Body ported Base mounted (4 port) (Manifold use only) SYJA3 30 2 Base mounted (5 port) SYJA3 40 2 Port size Type of actuation Nil Without sub-plate 4 3 2 position double 2 position single 2 1 M5 port With sub-plate M5 3 position closed center Symbol 5 port 4 port 3 position exhaust center 5 3 position pressure center 2 position single 2 position single (B)2 4(A) (B)2 4(A) 1
Dynamic viscosity [m2/s] Viscosity [Pas] Density [kg/m3] Formulas below can be used for common units 1cP = 1mPas = 10-3Pas 1cSt = 1mm2/s = 10-6m2/s Pulsation Attenuating Capacity The process pump generates pulsation because it discharges a liquid using two diaphragms.
Manufacturer M4 x 0.7 M3 x 0.5 Thread size 32.5 21.5 Effective thread length (mm) 8 6 Quantity 2 4 P.C.D. 46 45 Motor mounting area When mounting a coupling on the motor, mount it within the dimensional range shown on the left. A A B Section BB P.C.D.
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Display + 12 to 24 VDC 2% F.S.1 digit (25C3C) Display accuracy Black OUT Light up when output is turned ON. (Green) Indicator light Load Enclosure IP40 Environment resistance Blue DC () 3.4 3-wire 25AWG 2 m Lead wire with connector 11
Display + 12 to 24 VDC 2% F.S.1 digit (25C3C) Display accuracy Black OUT Light up when output is turned ON. (Green) Indicator light Load Enclosure IP40 Environment resistance Blue DC () 3.4 3-wire 25AWG 2 m Lead wire with connector 11
No.EX-OMO0007-E PRODUCT NAME SI unit for CC-Link MODEL / Series / Product Number EX180-SMJ3/5# Series Contents Safety Instructions 2 How to Order 7 Summary of Product Parts 8 Definition and terminology 8 Installation and Cabling 9 General Instructions on installation 9 Connecting cables 10 LED Display and Settings 12 Troubleshooting and Maintenance 16 Maintenance 20 Specifications 21 Table
Note 2) When the compressor oil mist discharge concentration is 30mg/m3 (ANR). Accessory part no. Accessory Applicable model AFD20 AFD30 AFD40 AFD40-06 AFD40 Note 1) Bracket assembly AF20P-050AS AD27 AF30P-050AS AD38 AD38NNote 3) AF40P-050AS AD48 AD48NNote 3) AF40P-070AS AD48 AD48NNote 3) N.O. N.C.
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Model AU ALU ALHU F R Barb fitting M3, M5 M3 M5 Barb elbow Barb one-touch Reducer Removing tubing Withdraw the sleeve straight along the tubing. Use a tool such as long-nose pliers if it is difficult to pull out by hand. 1. Withdraw the tubing straight. 2.
Model AU ALU ALHU F R Barb fitting M3, M5 M3 M5 Barb elbow Barb one-touch Reducer Removing tubing Withdraw the sleeve straight along the tubing. Use a tool such as long-nose pliers if it is difficult to pull out by hand. 1. Withdraw the tubing straight. 2.