Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.

C D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.

.: DXT170-75-1) VQZ Note) Ensure the locking type manual override is unlocked before using.

.: DXT170-75-1) VQZ Note) Ensure the locking type manual override is unlocked before using.

.: DXT170-75-1) VQZ Note) Ensure the locking type manual override is unlocked before using.

ZPG10B-7A-X2 7 7 7 8 ZP10B ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12 12 14 ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2

ZPG10B-7A-X2 7 7 7 8 ZP10B ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12 12 14 ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2

View B-B 50 HRZ HRZD Accessory: Y-strainer mounting view HRW * Mount it by yourself on the circulating fluid return port.

size: 32A, 40A, 50A Applicable cable O.D. 6 to 8 (D, DL) Pg9 Pilot port 12 (P1), 10 (P2) Port size: refer to table below Manual override (Non-locking push type) G (Air operated) H (Grommet: G) I (DIN terminal: D, DZ) P1 P2 F E D A B B C A J Main port 1 (A) (Back side 2 (B)) Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H I J Model VNA5-32A VNA6

B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3. ---(AL.01)6 1: Default when CO02 is set to PRO1 or PRO2. 4: Default when CO23 is set to A.SEL. 2: Default when CO15 is set to SW-A or SW-B. 5: Default when CO26 is set to A.SEL. 3: Default when CO19 is set to SW-A or SW-B. 6: Default when CO29 is set to A.SEL.

output signal 3 B contact (normally closed) By default 2.4.2 Contact output signal 4 to 6 Contact output signal 4 to 6 can be set to "signal type", "contact form".

AF-OMX0052-C PRODUCT NAME Air Filter MODEL / Series / Product Number AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D AF50-(F,N)06(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D AF60-(F,N)10(B,C,D)(-2,6,8,J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2.

(mm) a b Effective area (mm2) Weight (g) D L M2 Model 3.2 4 KJH02-23 KJH02-04 8.4 9.3 26.6 26.6 8.8 8.8 12.7 12.7 0.9 0.9 2.4 3.2 2 M1 M2 D D L Applicable tubing a Applicable tubing b Male elbow: KJL T H A Applicable tubing O.D.

(2) Conversion formula from the flow gauge measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Flow range Inclination a Intercept b 1 L 0.00025 0 2 L 0.0005 0 5 L 0.00125 0 L/min 10 L 0.0025 0 25 L 0.00625

With drain With drain With drain With drain With drain gauge guide cock guide cock guide B B B B B B B B B AFF20 159. 6 159. 4 146. 1 142. 1 148. 6 AFF30 219. 8 219. 8 219. 8 186. 6 184. 9 180. 6 185. 1 200. 6 205. 1 AFF40 263.3 265.1 265.1 232 230. 3 225. 9 230. 4 245. 9 250. 4 -31- Revision history Revision A: September 2020 Addition of the Series 20 and 40 Revision B: August 2021 Addition

With drain With drain With drain With drain With drain gauge guide cock guide cock guide B B B B B B B B B AMD20 159. 6 159. 4 146. 1 142. 1 148. 6 AMD30 219. 8 219. 8 219. 8 186. 6 184. 9 180. 6 185. 1 200. 6 205. 1 AMD40 263. 3 265. 1 265. 1 232 230. 3 225. 9 230. 4 245. 9 250. 4 -31- Revision history Revision A: September 2020 Addition of the Series 20 and 40 Revision B: August 2021 Addition

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.

N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40W-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50W-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D Contents Page 1.

For pipe fitting 4B through 6B Applicable fittings For pipe fitting 3/4B through 3B Welding Welding Piping B Reducing tees B 1 1 x 1 x 1 24 or more 11/4 11/2 11/4 x 11/4 x 1 1B socket 11/2 x 11/2 x 1 cut in half 2 x 2 x 1 2 21/2 x 21/2 x 1 21/2 3 x 3 x 1 3 Pipe 4B through 6B Reducing tees B Socket Pipe : JIS B 2301 : JIS B 2302 : JIS B 3452 Without flash 16-12-8 Paddle Style Flow Switch Series

Conduit terminal: VP3145-T A B DIN terminal: VP3145-D A B [105] 76 Light (For TL, TZ) 30 31.3 Max.12 G1/2 Applicable cable 6 to 12 Light position (For DL, DZ) G1/2 [196] NO NO 190.6 194 181.5 166 PE PE 26 26 83 83 32 32 36 36 80 80 [ ]: With indicator light (TL, TZ) 1310 Large Size 3 Port Solenoid Valve VP3165 Series Dimensions: VP3165 Grommet: VP3165-G A B 113 87.4 54 30 71 101 G1/2 1