SMC Corporation of America
Elite Part Number Search
Search Results "RDQB50-50M-M9BZ"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Size: 16, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 16: 10; Size 25: 12; Size 32: 16), Stroke: 50mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)

Size: 16, Motor Mounting Position: R (Right Side Parallel), Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: A (Size 16: 10; Size 25: 12; Size 32: 16), Stroke: 50mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP

Size: 16, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: C (Size 16: 2.5; Size 25: 3; Size 32: 4), Stroke: 50mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)

Size: 16, Motor Mounting Position: Top Side Parallel, Motor Type: H (Battery-less Absolute, Step Motor 24 VDC), Lead, mm: B (Size 16: 5; Size 25: 6; Size 32: 8), Stroke: 50mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Controller Position: B (Integrated Controller), Parallel Input: 6 (PNP)

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

C55 double acting, air operated cylinders were designed to meet a broad range of automation machine applications.  The C55 series achieves outstanding load performance due to its unique rubber bumpers, piston wear ring, and rod bushing.  Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm

Valve Type: XLDV (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC)

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: G [Grommet

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical

Valve Type: XLAV (Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: M (w/o Indicator, Right Flange Surface, Std. Indicator, Right Flange Surface), Version: 2, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: G [Grommet

Size: 40, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32/40, 4), Stroke: 50mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped, Body Bottom Tapped, Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting

Size: 25, Motor Mounting Position: D (In-line), Lead: C (Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M1 (1.5), Controller: C51 [Parallel Input (NPN)], Controller Mounting: 7 (Screw Mounting), Communication Plug Connector