SMC Corporation of America
Elite Part Number Search
Search Results "LVM20R3-5A-10-Q"

Note 8) : For pipe thread type: NPT only 1069 A Air Filter 1021-AF-A Standard Specifications Model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 1 10-/21-AF60-A 10-/21-AF40-06-A 10-/21-AF50-A Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 5 to 60C (No freezing) Ambient & fluid temperature 5 m Nominal filtration rating 1600

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series

Refer to gauge guide (P.94,95). t t r w w w q q q Sample Order Number Port t r q 4 4 4 4 4 w 4 4 4 4 4 AK1002S e 2P 3P 4P 4PL 5PC 2P 3P 4P Pressure gauge unit 2) MPA MPA MPA MPA V3 V3 V3 V3 t r t 1 Unit psig/bar MPa Code 0 0 No code MPA w w q q 1 2) Pressure gauge unit MPa or psig/bar selectable.

: 2 to 10 stations U side: 2 to 10 stations Nil Standard length (Specify a longer rail than the standard length.)

YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.

Note 10) Fixed unit: kPa Note 11) When K, Q, R or S is selected, select K for e Combination of Supply Valve and Release Valve.

(mm) Model Effective area (mm2) H L1 L2 L3 L4 L5 L6 L7 Q M1 M2 18 2(A) 4 1(P) 4 1(P) R 2(A) 2(A) R 3(R) VHK R-04F-04F 47.6 23.8 23.8 16.5 51.6 15.8 15.8 3.4 1.2 41 3.5 11 VHK R-06F-06F 18 6 6 41 48.6 24.3 24.3 16.5 3.5 52.6 11 16.8 16.8 7.2 1.2 VHK R-08F-08F 18 8 8 41 52.4 26.2 26.2 16.5 3.5 56.4 11 18.7 18.7 9.7 1.2 VHK R-10F-10F 22 10 10 46 61 30.5 30.5 21.5 4 65 14 20.8 20.8 16.1 3.2 VHK

(mm) Model Effective area (mm2) H L1 L2 L3 L4 L5 L6 L7 Q M1 M2 18 2(A) 4 1(P) 4 1(P) R 2(A) 2(A) R 3(R) VHK R-04F-04F 47.6 23.8 23.8 16.5 51.6 15.8 15.8 3.4 1.2 41 3.5 11 VHK R-06F-06F 18 6 6 41 48.6 24.3 24.3 16.5 3.5 52.6 11 16.8 16.8 7.2 1.2 VHK R-08F-08F 18 8 8 41 52.4 26.2 26.2 16.5 3.5 56.4 11 18.7 18.7 9.7 1.2 VHK R-10F-10F 22 10 10 46 61 30.5 30.5 21.5 4 65 14 20.8 20.8 16.1 3.2 VHK

TH Rear cylinder Port TP w e r t q u i y w e r t q u i y Approx. Max. T1 Approx. Max. T1 Approx. Max. T2 Approx. Max. T2 Approx. T3 Cylinder with by-pass piping component parts No. 1 2 3 4 Quantity 1 1 1 1 Description Part No.

Flow rate (L/min) 50 A Bag Filter FGF Series Construction FGF1 FGF3-40 FGF5-60 Air release Nut Air release valve Pin q FGD Davit for cover Spring washer t u !0 y u o q Air release Fluid release FGE Retainer Handle FGG Guide slit Center bolt Bracket for V-band Air release valve FGA !1 t Inlet i FGC i Inlet Drain port FGF FGF r Pressure gauge !

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series

Regulator for adjusting supply pressure for additional air blow Regulator for adjusting supply pressure to the dust collector Ionizer Offset voltage: 10 v Static neutralization distance: 100 mm Discharge time: 0.3 s 1000 VR100 V q Air blow e Air blow Ion blow t w Air blow adjustable range r Secured a large static neutralization space.

Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110

M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.

9 q q !7 !7 IN OUT IN1 OUT1 !0 !6 !3 o !3 q !8 !6 IN2 OUT2 !8 !7 !6 o IL220 !3 r e !2 w u y i !9 !5 @1 OUT IN1 !1 q @2 @0 IN2 !4 q Component Parts Replacement Parts No. Description Material Note 1 Body Aluminum alloy Silver baking finish Model Order no. Contents IL201 KT-IL201 Set of left nos. u, i, o, !2, !3, !6, !7, !8, !9 IL211 KT-IL211 Set of left nos. u, i, o, !0, !2, !3, !6, !7, !

10 14 14 22 22 23 23 30 30 42 42 U CX L Z + Stroke RR ZZ + Stroke Double clevis/(D) Port Cushion valve Double clevis CDH10 (mm) Bore size (mm) Stroke range H10 CX +0.3 ZZ Z U RR L CD +0.1 CZ 32 40 50 63 80 100 164.5 169 197 197 251 251 154 158 182 182 228 228 13 13 17 17 26 26 14 14 20 20 30 30 10.5 11 15 15 23 23 up to 500 up to 500 up to 600 up to 600 up to 750 up to 750 10 10 14 14 22

-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-l01 G49-4-l02 0.4 MPa G49-2-l01 G49-2-l02 0.2 MPa Round type Note 2) G49-7-l01 G49-7-l02 0.7 MPa Pressure gauge ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body

Symbol -X80, -X81 Main Value Double Acting Type 1 A N 06 5 1 4 VP31 1 D Z X81 Body size CE marking Nil Q None CE-compliant 4 6 8 1/2 1 1 1/2 3/8 1/2 3/4 1 1 1/4 1 1/2 2 Port size (IN, OUT port) Thread type Symbol VP3145 VP3165 VP3185 Port size Nil F N T D/DO/DZ/DU only Rc G NPT NPTF 03 04 06 10 12 14 20 Type of actuation X80 X81 Double solenoid Single solenoid External pilot Passage, Type

10 .2 10.1 .2 10.2 .3 10.3 CC-Link .3 10.4 .4 10.4.1 .4 10.4.2 .5 10.4.3 .14 10.5 .16 10 1 10 10 10.1 MR Configurator 1 LED LED CN6CN2CN3 1. 2.