SMC Corporation of America
Elite Part Number Search
Search Results "LLB4-3N-F"

(2.8) 3/h) 3/h) 3/h) 3/h) (182m (273m (384m (510m (ANR) (1) 120SCFM 173SCFM 258SCFM 353SCFM 45 F (7.2) 3/h) 3/h) 3/h) 3/h) (205m (294m (438m (600m 130SCFM 181SCFM 297SCFM 406SCFM 50 F (10) 3/h) 3/h) 3/h) 3/h) (221m (308m (504m (690m 100psi (0.7MPa) 100 F (37.8) 100 F (37.8) 41122 F (550) 22 150psi (0.15 ~ 1.0MPa) 36-104F (2~40) 85% (4) AC115V10% AC230V10% (60Hz) AC460V10% (60Hz

Function selection mode In measurement mode, press the button between 3 and 5 seconds, to display [F 0]. Select to display the function to be changed [F ]. Press and hold the button for 2 Measurement mode Power is supplied. Press the button between 3 and 5 seconds.

Caution: [F 4] Auto-preset function OFF [F81] Security code OFF Press the button once.

External Grip Internal Grip MHK2-12D MHK2-12D 25 20 Pressure 0.6 MPa Pressure 0.6 MPa Gripping force (N) Gripping force (N) 20 15 0.5 MPa 0.5 MPa 15 0.4 MPa 10 0.4 MPa 10 0.3 MPa F F 0.3 MPa 5 5 0.2 MPa 0.2 MPa 0 0 10 20 30 40 50 10 20 30 40 50 Gripping point L (mm) Gripping point L (mm) External grip Series MHK2 Internal grip Series MHK2 MHK2-16D MHK2-16D 50 50 Pressure 0.6 MPa Pressure

O.D.: 4, 5/32" : 6, 1/4" (2.3) L plug connector (L): SYJ5120-L-M5(-F) M plug connector (M): SYJ5120-M-M5(-F) DIN terminal (D): SYJ5120-D-M5(-F) M8 connector (W0): SYJ5120-W0-M5(-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3

(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.

Holding Force MHK2-12D MHK2-12D 25 20 Pressure 0.6MPa Pressure 0.6MPa 20 Holding force N Holding force N 15 0.5MPa 0.5MPa 15 0.4MPa 10 0.4MPa 10 0.3MPa F F 0.3MPa 5 5 0.2MPa 0.2MPa 0 0 1N = 0.2248 lbf = 0.102 kgf 1MPa = 145 psi = 10.2 kgf/cm2 10 20 30 40 10 20 30 40 50 50 Holding point L mm Holding point L mm O. D. holding MHK2 series I.

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

) Note 4) PE (M5 x 0.8) 29.4 3 20.2 P 20.3 9.7 V Exhaust part 0.8 17.7 22.8 87.2 10 Note 1) The above dimensions are for ZQ11U-J2 L-F.

H1 AL A K F N N 71 LL S + Stroke H ZZ + Stroke ZZ + l + Stroke h + l Bore size (mm) Stroke range (mm) 40 50 63 80 100 A AL B B1 C D E F H1 I K KA LL MM N Q S J Up to 500 Up to 600 Up to 600 Up to 750 Up to 750 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 30 35 35 40 40 84 90 98 116 126 The minimum stroke of the one with rod boot is

FOOl alldilional options F Flan e T, Center trunnion Applicable auto swnch J32 32mm 40 40mm 50mm 63mm BOmm "so , 63' * Re!el lO tabIt be!o'lr fo, se!

105 CKZ80-42 3680N-R D E F 30 to 105 For mounting bolt, a hexagon socket head cap screw and a spring washer No. 2 are recommended.

Water Hammer Characteristics VNC1 (N.C. 0.49 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.49 MPa VNC4 (N.C. 0.97 MPa) Conditions: Piping 30 m Steel tube, total pressure 0.97 MPa 2.5 15A Peak pressure at valve closed (MPa) Peak pressure at valve closed (MPa) 8A 25A 2 1 20A 32 A F 15A 20A 40 A F 32 A F 1.6 0.8 25A 40 A F 50 A F 65F 50 A F 1.2 0.6 80F 65F 80F 0.8 0.4 0.4 0.2 0 1

.) : Setting of the normal/reverse output switching and hysteresis/window comparator mode switching are performed with the function selection mode [F 1] OUT1 setting and [F 2] OUT2 setting. Peak/bottom value indication The max. (min.) pressure when the power is supplied is detected and updated.

(The default setting does not include arbitrary display.) 6 Display colour Output ON: Green/ Output OFF: Red (Linked to OUT1) 9 8 8 [F 0] Setting of the switching function of the pressure range, display unit and switch output specifications is completed. 4.5 4.5 [F 2] Setting of OUT2 Same setting as [F 1] OUT1. 28 Press the button between 1 and 3 sec.

Standard condition [F 4] [F 5] [eES] Response time [1.00] 1 second Specifications / Outline with Dimensions [F 6] [dSP] Display mode [ inS] Instantaneous flow [F 7] [ inP] External input [ r_r ] Accumulated flow external reset Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about the product specifications and outline dimensions. [1E2] 100-

F luid flow s from the suction port F L UID IN to the discharge port F L UID OUT . It takes a w hile for pulse attenuator to operate. pump also stops w hen ball valve is closed on the discharge side. A void stopping the pump for long hours, as this may prevent restart of the pump. C losing valve abruptly can generates surge, that considerably shortens the life of the pump.

Field name Example RTU mode ASCII mode (HEX) character data binary data Header : None Device address 0x01 0,1 0x01 Function 0x04 0,4 0x04 Quantity of bytes to read 0x02 0,2 0x02 Information of 0009h(Data display 1) 0x00FA 0,0,F,A 0x00,0xFA Checksum ASCII:LRC RTU:CRC F,F 0x39,0x73 Trailer CR/LF None Total quantity of byte 15 7 * Response message at an ambient temperature of 25.0C 3.13 Register

Move M Speed Position Pushing F TriggLV In pos Change of positioning stop position Position: 50mm 30mm mm/s mm % % mm 0 Absolute 250 50.00 0 0 0.50 Input 30 Step data No. Move M Speed Position Pushing F TriggLV In pos mm/s mm % % mm 0 Absolute 250 30.00 0 0 0.50 6.