x 3 x 60 = 2736g/h. 6 7 8 3 1 2 3 4 5 Dew point conversion chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric pressure dew point C 8
(mm) Model Flange Note) Kv Conversion Cv Rc VND10D-6A VND10D-8A VND10D-10A VND20D-10A VND20D-15A VND30D-20A VND40D-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 0.9 1.0 1.1 4.3 4.6 8.6 13.6 1.1 1.2 1.3 5.0 5.4 9.9 16 1 8 1 4 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 25 1 1 4 1 15.7 18 32 32 1 2 1 32.9 38 40 40 2 53.6 50 62 10.8 50 Note) The companion
Contact capacity 50 VA AC, 50 W DC 1 2 5 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Pressure gauge for supply pressure Pressure gauge for tank pressure Pilot valve Recommended Equipment AIR BLOW Supply pressure AIR It is recommended to use each mist spray unit type with the mixing valves, magnet holders, branch pipes and nylon tubes listed in the table below.
Basic type Standard/Thread nominal size JC20-8-125 JC30-10-125 JC40-14-150 JC63-18-150 0.5 0.5 0.75 1 300 800 1250 3100 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 20 25/32 40 50/63 5 Semi-standard/Thread nominal size JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 M8 x 1 M10 x
99 50 44 59 22 1/8 VCB21 M4 12.8 18 28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94 50 8 30 111.5 70 78.5 103 78.5 48 88 26 1/2 M5
Specifications Product specifications Standards Conforming to ISO 9409-1-50-4-M6 Applicable fluid Air Operating temperature range [C] 5 to 50 Weight [g] (Except cups with adapter) 228 Max. work load [kg] Note2) 7 Air pressure supply (P) port M5x0.8, Rc1/8 Applicable suction cups Refer to 3.3. How to order Note 1) The weight changes by the selected suction cup. Refer to 3.3 How to order.
Ensure the piping cools sufficiently before touching. 50% of maximum rated flow [ 50] 50 oC (for all ranges) [ tn_2] Set value (OUT2) Pin number of the connector (On the lead wire) 90o End stop position 0% of maximum rated flow [ 5] 5 oC (for all ranges) [ tH_2] Hysteresis (OUT2) After maintenance is complete, perform appropriate functional inspections and leak tests.
VR VH VHS Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.
12 3 450 10 2 400 10 2 350 8 1 300 8 1 250 6 0 200 6 0 150 6 0 100 Stroke F E Stroke F E 20 7 900 20 7 850 18 6 800 18 6 750 16 5 700 16 5 650 14 4 600 14 4 550 22 8 950 22 8 1000 13 Electric Actuator/Maintenance Guide 1 Be sure to read before handling.
rated voltage Allowable voltage fluctuation Coil insulation type Class B 500 VDC, 10 M or more Insulation resistance Voltage limit 1800 VAC, 1 sec., 3 mA or less Simulation noise: 500 Vp-p (Based on 1 sec. pulse width, 50 10 Hz frequency noise simulation) Noise tolerance Note 3) Fast transient noise: IEC61000-4-4: 1 kV VDW30: 3 W (With 0.5 W power-saving circuit) VDW40: 6.5 W (With 1 W
(Flat type) 1 2 Rod end cap (Round type) 1 2 T-bracket 32 50 Accessories * Mounting nut and rod end nut are included in the basic weight.
0.03 Ball screw 3 100 50 Series LXP 6 Ball bushing guide 100 Ball screw 0.03 50 5 100 Series LXS 50 10 High rigidity direct acting guide 100 Ball screw 0.03 50 5 100 5 Simplified Selection Flow Chart Series LX Standard stroke (mm) and 25 50 75 100 125 150 175 200 Model Motor Manufacturer Maximum speed (mm/s) Phases LXFH5SB LXFH5BC LXFH5BD LXFH5SA 5 phase to 200 5 phase to 30 Sanyo
Source voltage F G N NPT 0 Single phase 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) 1 Single phase 110 VAC (50 Hz) JIS Symbol 5 Single phase 200 VAC (50 Hz) 200 to 220 VAC (60 Hz) 6 Single phase 220 VAC (50 Hz) 14-19-1 2 Series ID Working Principle Flow Rate Inlet pressure: 0.7 MPa The compressed air that flowed in from the IN side passes through the 4 way solenoid valve, and after it is dehumidified
Applicable bore A B A B A B MY-S25 MY-S32 MY-S40 ML1C25 ML1C32 ML1C40 103 117 35 50 8 5 9.5 5.5 M6 x 1 128 146 45 64 11.7 6 11 6.6 M8 x 1.25 148 170 55 80 14.8 5 14 9 M10 x 1.5 1114 A Hy-rodless Cylinder ML1C Series Construction #9 %7 #8 #7 %6 !0 CLJ2 CLM2 CLG1 CL1 w $8 @4 i u !7 t !2 $9 !3 !1 %5 @6 @5 $5 #6 MLGC %2 CNG @8 !9 MNB e CNA2 $2 q %3 %4 $1 CNS #1 #0 @9 #4 $0 !5 !
Internal construction with auto switch Model Auto switch unit part number MDSUA1, 3 MDSUA7, 20 P211070-1 MDSUA 1 P211090-1 MDSUA 3 P211060-1 MDSUA 7 Auto switches are not included with switch units.
How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6. 4-16-1 2 Series VS3115/3110 How to Order VS311 D L 5 01 5 Thread type Accessory (Option) Nil Rc Mounting With indicator light L P With manual override N NPT T NPTF E Nil Without bracket Port size Piping Electrical entry B With bracket G 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate Rc 01 02 02 03 00 Body ported
1/4 Non-lube 150 to 700 45 1/8 150 to 1000 200 to 1000 50 1/4 60 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Size Suction flow rate L/min (ANR) 20 25/32/40 Bore size (mm) Item 20/25/32/40 1 2 1.5 MPa 1.0 MPa 0.2 MPa 10C to 60C (With no freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed
Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.
Note 3) Refer to the catalog, since the dimensions of standard stroke Series CQ2 and CQS are different from that of long stroke type. 6-18-1 2 SMC Actuators: Copper-free Air Cylinders 6, 8, 10, 12, 15, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 140, 160 Air Cylinders 20-series has been added by design modification. (98.6.1) Series Application Bore size (mm) Standard Copper-free 6 8 12 (10