SMC Corporation of America
Elite Part Number Search
Search Results "JS63-18-150"

16 34 312 MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 12 9 11 9 20 105 Normally open Normally closed MHKL2-16S 16 17 14 14.6 28.6 165 MHKL2-20S 20 32 18 16 34 314 MHKL2-25S 25 53 22 19 41 565 MHKL2-12C 12 11 11 9 20 105 L1 MHKL2-16C 16 22 14 14.6 28.6 166 L2 MHKL2-20C 20 40 18 16 34 314 MHKL2-25C 25 63 22 19 41 565 Note) At the pressure of 0.5 MPa, when gripping point L is 20 mm.

Select a bore size in accordance with Model Selection on pages 17 and 18.

28.6 33.6 6.2 50 11.4 16.5 3/16" AS2001F-05 AS2051F-06 26 30.2 35.2 6.7 53.2 12.8 6 17 14.8 21 29.5 34.5 7.1 52.2 13.2 17 1/4" AS2001F-07 AS2051F-08 31 31.5 36.5 8.1 59.8 15.2 8 18 24 29.6 34.6 6.2 52.2 11.4 16.5 3/16" AS2051F-05 AS3001F-06 18 33.3 38.3 7.4 59 12.8 6 17 14.8 26 30.5 35.5 7.1 54.4 13.2 17 1/4" AS2051F-07 AS3001F-08 21 34.1 39.1 8.2 64.4 15.2 8 18 19.8 31 31.5 36.5 8.1 59.8

16 34 312 MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 12 9 11 9 20 105 Normally open Normally closed MHKL2-16S 16 17 14 14.6 28.6 165 MHKL2-20S 20 32 18 16 34 314 MHKL2-25S 25 53 22 19 41 565 MHKL2-12C 12 11 11 9 20 105 L1 MHKL2-16C 16 22 14 14.6 28.6 166 L2 MHKL2-20C 20 40 18 16 34 314 MHKL2-25C 25 63 22 19 41 565 Note) At the pressure of 0.5 MPa, when gripping point L is 20 mm.

16 34 312 Auto switch MHKL2-25D 25 22 19 41 562 MHKL2-12S 90 105 20 9 11 12 9 Normally open Normally closed MHKL2-16S 165 28.6 14.6 14 16 17 MHKL2-20S 314 34 16 18 20 32 MHKL2-25S 565 41 19 22 25 53 L1 Single acting MHKL2-12C 105 20 9 11 12 11 L2 MHKL2-16C 166 28.6 14.6 14 16 22 MHKL2-20C 314 34 16 18 20 40 MHKL2-25C 565 41 19 22 25 63 Note) At the pressure of 0.5MPa , when holding point

When closed 6.6 When open 12.6 5 Parallel Type/Standard Type Series MHZ2 MHZ2-20 Scale: 60% 35 18.6 2-M5 x 0.8 thread depth 8 (mounting thread) 4H9 depth 4 +0.030 0 4-M5 x 0.8 thread depth 10 (mounting thread) Prepared hole dia. 4.3 through (mounting hole) Note) 7.5 0.02 0 -0.7 8 0 -0.1 30 32 42 50 16.8 0.02 +2.2 -0.2 21H9 depth 3 +0.052 0 20 29 When closed 16.3 18 When open 26.3 9.5 52.8

8 10 20 6 21 16 2 1 19 5 18 10 8 3 24 13 9 7 22 14 4 11 15 12 3 24 13 23 22 7 4 11 MXH16, 20 (16, 20) 20 6 21 17 2 1 19 5 18 18 8 10 4 7 22 23 13 24 3 12 11 Parts list Parts list Description Material Note Description Material No.

I.D. 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 10 17 19 17 19 20 18 21 20 18 21 20 22 21 25 22 21 25 23 22 25 23 22 25 21 25 22 27 38 30 32 39 31 32 37 38 44 66 38 43 65 53 53 68 51 52 67 KFL04-01 KFL04-02 KFL06-01 KFL06-02 KFL06-03 KFL08U-01 KFL08U-02 KFL08U-03 KFL08N-01 KFL08N-02 KFL08N-03 KFL10U-02 KFL10U-03 KFL10U-04 KFL10N-02 KFL10N-03

Parameter Configuration using Setup software (MR Configurator2TM) 16 6.1 Setup software (MR Configurator2TM) . 16 6.1.1 Installation Method . 16 6.2 Basic driver set-up for Initial Test Drive . 16 6.2.1 Start up the Setup software (MR Configurator2TM) . 17 6.2.2 System Settings . 18 6.2.3 Model Selection . 18 6.2.4 Driver ON LINE Check . 19 6.2.5 Help Function . 19 6.3 Parameter setting (

L* N x 4 N x 8 N x 12 N x 6 N x 12 N x 18 N x 8 N x 16 N x 10 N x 20 N x 12 N x 24 D 18 28 28 24 37 37 31 42 52 52 67 67 TCU0425-1N-X6 TCU0425-2N-X6 TCU0425-3-N-X6 TCU0604-1-N-X6 TCU0604-2-N-X6 TCU0604-3-N-X6 TCU0805-1-N-X6 TCU0805-2-N-X6 TCU1065-1-N-X6 TCU1065-2-N-X6 TCU1208 -1-N-X6 TCU1208 -2-N-X6 LX5.9 + 200 LX4.4 + 200 LX2.9 + 200 LX5.3 + 200 LX3.8 + 200 LX2.5 + 200 LX5.2 + 200 LX3 +

G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer

10 14.5 4.5 U40 40 43 7 18 13.7 18.5 6.5 U50 50 53 7 18 14.7 19.5 7.5 Model Nom.size D10 A 10 ZP10Dl B 12 C 4 D 13 E 10.7 F 15 Y 6 Put in the symbol for material at the end of model no.

B 13 1 1 1 3 R1 P R2 32.5 45.5 2-M5 X 0.8 31.5 38 (pilot port) 64 3.2 269.5 14 (Non-locking) Manual override (Mounting holes) 35 89 (Non-locking) Manual override 3-Rc(PT)1/8, 1/4 (P, A, Bport) 29 28 25 21 1.6 14 89 18 21.8 (Bleed hole) With filter (80 Mesh) 55 2-1.8 (Bleed hole) With filter (80 Mesh) 40 25.5 20 R1 R2 P 11.5 12 18 22 22 27.2 (R1, R2 port) 2-Rc(PT)1/4 63 5-Rc(PT)1/8 (Piping

8 16 (0.9) 18 (1) 02 03 VFA31402 position single 0.31 1 8 1 4 3 8 16 (0.9) 18 (1) 02 03 VFA32402 position double 0.33 1 8 Body ported 1 4 3 8 12.5 (0.7) 14.5 (0.8) 02 03 VFA3340-X1 3 position closed center 0.48 1 8 JIS Symbol 1 4 3 8 16 (0.9) 18 (1) 02 03 VFA3440-X1 3 position exhaust center 0.48 1 8 2 position double 2 position single 1 4 3 8 12.7 (0.7) 8.2 (0.45) 13.3 (0.75) 8.7 (0.5) 02

MK/MK2 RSQ/RSG RSH A CE1 Auto switch mounting position Auto switch model D-Z7l D-Z80 D-Y59 D-Y7P D-Y69l D-Y7PV D-Y7lW D-Y7BAL D-Y7lWV CE2 ML2B Bore size (mm) A B A B A B A B 20 18 8 18 9.5 18 2 18 4 ML1C 32 13.5 10 13.5 12 13.5 4.5 13.5 6.5 50 21.5 12 21.5 14 21.5 6.5 21.5 8.5 REA 63 16.5 31 16.5 33 16.5 25.5 16.5 27.5 80 26 33 26 35 26 27 26 29 REC RHC How to Install an Auto Switch MTS To

/Current) Enclosure IP40 IP40 Piping M5 female thread, R1/8, NPT1/8 Note Copy function, Auto-shift function CONTENTS 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series How to Order p. 9 Specifications p. 10 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 18

13.6 2.7 14 PF3W720 3/8 1/2 78 54 30 60 40.6 15.2 27 18 39 30 18 13.6 2.7 12 PF3W740 1/2 3/4 98 71 38 68 48.6 19.2 32 28 49 35 28 16.8 2.7 12 PF3W711 3/41 124 92 46 77 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W704 24 22 32 40 50 4.5 5 1.5 PF3W720 28 22 32 40 50 4.5 5 1.5 PF3W740 34 30 42 48 58 4.5 5 1.5 PF3W711 44 36 48 58 70 5.5 7 2 -81No.PF-OMM0004-D PF3W721 A AA B D E F G

13.6 2.7 14 PF3W520 3/8 1/2 78 54 30 45.6 40.6 15.2 27 18 39 30 18 13.6 2.7 12 PF3W540 1/2 3/4 98 71 38 53.6 48.6 19.2 32 28 49 35 28 16.8 2.7 12 PF3W511 3/41 124 92 46 62.6 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W504 24 22 32 40 50 4.5 5 1.5 PF3W520 28 22 32 40 50 4.5 5 1.5 PF3W540 34 30 42 48 58 4.5 5 1.5 PF3W511 44 36 48 58 70 5.5 7 2 -41No.PF-OMN0009CN-F PF3W521 2X A AA

Refer to page 4-18-4.) Ambient and fluid temperature Response time (at 0.5 MPa) (1) 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)

mounting) 2-M5 x 0.8 (Pilot port) 17 B A 1 34 27 13 1 B A A B 3 1 1 R1 P R2 32.5 45.5 2-M5 x 0.8 31.5 38 (Pilot port) 64 2-3.2 Manual override 69.5 14 35 (For mounting) 89 Manual override 1/8,1/4 (P, A, B port) 29 28 25 21 1.6 14 89 18 2-1.8 (Bleed port) 55 With fiflter (80 mesh) 2-1.8 (Bleed port) 40 25.5 20 11.5 12 R1 R2 P With fiflter (80 mesh) 18 22 22 1/4 27.2 63 1/8 (Piping port) (