Otherwise malfunction can result, causing an accident. : Thread size: M3 x 30 Node ID setting No.1 Reserved Technical documentation giving detailed specification information can be found on the SMC website (URL http://www.smcworld.com). The following instructions must be followed during maintenance: Turn off the power supply.
M3 0.610.63Nm 1) 12mm 10mm -10- 2)L L 4 -11- L (M3X6)L :0.610.63Nm M3 -12- L L M3 (M3X6) :0.610.63Nm 3) :0.610.63Nm 90 -13- 4)DIN L :0.610.63Nm (M3X6)L :0.610.63Nm DIN :0.610.63Nm -14- 5) :0.610.63Nm 3 M3 L DIN -15- 4 4 4 4-3. 3. 3. 3. 1 +24V 2 GND 3 OFF 4 ONOFF OFF 5 0N 6 OFF 7 ON 8 1 ON 9 2 ON ()D ON NPN:GND ONOFF PNP:24V ONOFF NPN:(GND )ONOFF
Mounting bracket Ass'y Mounting screws Controller model M3 x 0.5 LC1-1-N3 LC1-1B-N3 M5 x 0.8 LC1-1-N5 LC1-1B-N5 M3 LC1-1-L3 LC1-1B-L3 M5 LC1-1-L5 LC1-1B-L5 Note) This controller comes with either the T-nuts or T-brackets as accessories.
IDFA4E15E1 L N PE M3 6.5mm 1.25mm 2 1-1 IDFA Series 1 4 IDX-OM-W017 2 2 , 2 1 IDFA4E15E 20kg 2 2 2 2 2 1 2000m 240 050 600mm 600mm 600mm ( 600mm ) 600mm 2-1 IDFA Series 2 1 IDX-OM-W017 2 2 2 2 6 6-2 IDFA4E15E 2 2 3 50 50 2 2 4 10mm 2-2-2 IDFA Series 2 2 IDX-OM-W017 2 ( 2 2 5 6-1 IEC AC230V 30mA 5A 216AWG,3 ,812 1.25 0.1m 30m M3 1.25-3 6.5mm ()M3 0.61Nm
L N PE M3 6.5mm 1.25mm 2 :17 1 2 2 2 , 2 1 IDFA6E 20kg 2 2 2 2 2 1 240 050 ( ) 2000m 600mm 600mm 600mm 600mm 600mm 2 1 2 2 2 2 6 6-2 2 2 3 50 50 2 2 4 10mm ( 2 2 2 2 2 5 6-1 IEC AC200V 30mA 5A 1.25 216AWG,3 ,812 0.1m 30m M3 1.25-3 6.5mm () M3 0.61Nm 2 3 2 2 3 () 2 2 () 2 4 3 / 3 3 1 INOUT 3 2 ON () INOUT 5 ONOFF 0.15MPa NO IN 3 1 3 / 3 3 OFF OFF
m5 m GH641 m3 m5 m 200 kPa ISA3-F ISA3-G 1 m3 m5 m 1 m3 m5 m [mm] [mm] 9 0 10010 ISA3-H 1 m3 m5 m [mm] 29 0 30030 -19No.PS-OMR0001CN-J 2 ISA3-() ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 C(4 ) C(6 ) F(G ) H 13 13.6 19 ISA-14() -20No.PS-OMR0001CN-J 2 ISA3-(DIN ) ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 L2 62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5
m5 m GH641 m3 m5 m 200 kPa ISA3-F ISA3-G 1 m3 m5 m 1 m3 m5 m [mm] [mm] 9 0 10010 ISA3-H 1 m3 m5 m [mm] 29 0 30030 -20No.PS-OMT0001CN-E 2 ISA3-() ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 C(4 ) C(6 ) F(G ) H 13 13.6 19 ISA-14() -21No.PS-OMT0001CN-E 2 ISA3-(DIN ) ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 L2 62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5
M3 hexagon screw Tightening torque 0.6 Nm Terminating resistor Valve manifold : Thread size: M3 x 30 Troubleshooting The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 84.00000 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 84 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 89.1 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 106.9 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 84 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 84.4 lb
2 Station Mfld, Non Plug-in Metal Base, 4/5 PORT SOLENOID VALVE, O84, 84.4 lb
M3 4 M3 4 3 90 2 AS-10AB 5 135 2 AS-11AB 7 180 2 AS-12AB 9 220 2 AS-13AB Ex.) AS2002FS-06 When connecting 4 pcs. and mounting L-brackets on both sides AS-20A Speed controller AS2002FS-06 4 pcs. 3 111 2 L-bracket AS-20L 2 pcs.
MM Bore size (mm) NB NDh8 24.5 20.5 20.5 GC F D BB A 6 10 16 NN Z 85.5 82 83 T 3 CA GA BA CB GB 5 5 S NA H 28 28 28 M3 x 0.5 M8 x 1.0 15 15 15 7 9.5 9.5 10-0.022 0 8-0.022 0 57.5 54 55 15 15 18.3 12 18.3 14 20 3 4 5 17 17 20 8 8 8 12 5 5 11 11 11 M10 x 1.0 M4 x 0.7 12-0.027 0 M12 x 1.0 M5 x 0.8 With air cushion Air cushion type is not available for 21-/22-CJ2.
Size (Nominal x Length) Quantity Metric size Inch size TMH-23J TMH-01J M3 x 15 TMH-04J TMH-03J TMH-06J TMH-07J M3 x 20 TMH-06 TMH-07 M4 x 25 TMH-08 TMH-09 TMH-10 M4 x 35 TMH-12 TMH-13 1 Series Holder mounting Select the applicable holder/TMH for each speed controller from the table below.
M3 x 5 L OUT1 [Default setting] OUT2 Both OUT1 and OUT2 Model: ZS-28-B Power and output lead wire with connector Operator Bracket Lever LCD display All of the settings are completed, and the controller will return to measurement mode.
Bracket mounting Mount the bracket using the mounting screws (M3 x 15 L) suppllied. The required tightening torque is 0.320.02 Nm. L-type bracket (Through hole) Mounting screw (M3 x 15 L) Mounting screw (M3 x 5 L) CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.