Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Applicable shaft type: K X = X = X = Y = W2 = L2 = L4 = Y = [mm] [mm] [mm] Size Y W2 L2max L4max 30 8.5 to 25 1 to 2 Y-2 L2-2 50 10 to 36 1 to 5.5 Y L2-2 63 11 to 41 1 to 6.5 Y L2-2 80 13.5 to 50 1 to 8 Y L2-3 100 17 to 60 1.5 to 10.5 Y L2-4 Size X 30 3 to 25 50 3.5 to 36 63 3.5 to 41 80 4 to 50 100 5 to 60 Size Y 30 3 to 25 50 1 to 36 63 1 to 41 80 1 to 50 100 1 to 60 Symbol: A53 Note) Except
LECSB1: Single phase 100 to 120 VAC, 50/60 Hz Connection terminal: L1,L2 LECSB2: Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1,L2,L3 Do not connect. L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.)
M2 8 4.2 Applicable tubing L2 M2 L2 Different Diameter Tee: KQ2T Applicable tubing Applicable tubing O.D.
A B L1 L2 14 12 A PA B A B 14 SMC A PA B A B A PA 40 (53) L-side R-side L-side R-side (2n-1/8) D-side D-side 14 34 103 2 103 174.5 (Single) 4n-3/8, 1/2 2, 4 port 94 62 59 17 174.5 (Single) 216.5 (Double) 216.5 (Double) 221.5 216.5 (3 position) 221.5 216.5 (3 position) Bottom ported M12 connector L: Dimensions n: Stations n P, R1, R2 port 2 3 4 5 6 7 8 9 10 1 Formulas L 157 L1 L2 L1 L2 176
(mm)
M1E m x g FE M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x ax m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420mm/s in Graph 3. M3 M3E m x g FE L2 From above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812.
(onpressed (tbr.) 0tltll.5lllxl 0.75 1.0 l2-140 ?
PD09PD11(MBR) 4 39 4 4.12 (PE)( ) (PE) (di/dtdv/dt) EMCEMC(IB()67303) NFB MC CN2 L1 () L2 L3 L11 U U L21 V V M W W CN3 PE PE (PE) PE .
E B1 B2 B3 L1 TG1 T l1 (Min.) l2 FL H (Max.) d1 d2 d3 CN SR (Max.)
E B1 B2 B3 L1 TG1 T l1 (Min.) l2 FL H (Max.) d1 d2 d3 CN SR (Max.)
Refer to page 83 for dimensions. 80 Accessories Series CP96/C96 Dimensions: Cylinder Mounting Accessories Single clevis (C) Double clevis (D) Series C85 Series CP96 Series C96 Series C55 l2 l2 CDH9 l1 l1 Bore size (mm) 32 40 50 63 80 100 125 l1 l2 E1 EW TG1 FL L d1 CD MR d2 R1 E2 UB CB 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.2 0.6 0.5 1.2 45 26 32.5 22 5 12 5.5 30 10 9.5 6.6 6.5 48 45
Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.