130 130 130 150 150 150 190 190 65 65 65 75 75 75 85 85 90 90 90 115 115 115 145 145 6 6 6 6 6 6 8 8 72 72 72 86 86 86 106 106 110 110 110 130 130 130 170 170 195 195 195 245 245 245 19 19 19 19 19 19 20 20 10 10 10 10 10 10 20 20 63 63 63 63 63 63 76 76 14 14 14 17 17 17 17 17 90 90 90 126 126 126 197 197 30 30 30 60 60 80 120 120 177 177 177 227 227 227 285 285 110 110 110 130 130 130
All are created to provide you with an array of solutions to help meet your design needs, such as a wide range of bore sizes stroke lengths, high precision performance, exceptional reliability, global availability and auto switch capability.
How To Order Lubricator Series AL20 to 40 AL 20 N 02 B X480 Z 2 Lubricator With External Epoxy Coating, Stainless Fasteners Body Size Symbol 20 30 40 Name Plate, Caution Plate On Bowl in psi, F Size 1/8 3/8 1/2 Bowl Applicable Body Size 20 30, 40 NPT Threads Description Metal Bowl Metal Bowl with Sight Glass Symbol 2 8 Port Size Symbol 02 03 04 Accessories Applicable Body Size 20 30 40 Port
How To Order Lubricator Series AL20 to 40 AL 20 N 02 B X480 Z 2 Lubricator With External Epoxy Coating, Stainless Fasteners Body Size Symbol 20 30 40 Name Plate, Caution Plate On Bowl in psi, F Size 1/8 3/8 1/2 Bowl Applicable Body Size 20 30, 40 NPT Threads Description Metal Bowl Metal Bowl with Sight Glass Symbol 2 8 Port Size Symbol 02 03 04 Accessories Applicable Body Size 20 30 40 Port
The allowable load mass and maximum operating pressure should be as shown in the table below. The cushion effect (smooth start-up, soft stop) is not available an intermediate stop or return from an intermediate stop using an external stopper, etc.
[r An] Select connected sensor [oFF] Unused Refer to the SMC website (URL http://www.smcworld.com) for more information about troubleshooting.
C) In order to generate a clamping force from the state described in step B), insert an additional shim. The thickness of the shim changes depending on the arm length and the operating pressure. Refer to page 9. Please note that the graph should only be used as a guide, as there is a tolerance of about 10% in the clamp cylinder body.
110 130 180 Q 26 28 28 34 34 50 50 60 76 R 4.5 5 5 5 5 9 9 10 12 S 1.6 2 2 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24 27 27
20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(
Conduct an appropriate functional inspection after completing the maintenance. Do not use chemicals such as benzin and thinner to clean the product. SAFETY ( continued ) As the cables with connectors are used for all wirings among devices, the system complies with the IP65 environment.
Tightening tools Tighten with an appropriate wrench using the hexagon wrench flats on the body. Position the wrench on the base as close as possible to the threads. If the size of the wrench is not suitable for the hexagon wrench flats, the wrench flats may be crushed. Caution KK Be sure to wrap sealing tape around the taper threads for both resin and metal threads.
O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110 110 130 180 Q 26 28 28 34 34 50 50 60 76 R 45 5 5 5 5 9 9 10 12 S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 T U 37 37 37 37 37 37 37 37 37 AFF 159 172 178 204 210 225 232 259 311 13 13 16 16 19 19 22 22 32 100 113 119 145 151 166 173 200 253 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 24 27 27 32
In this case, be sure to cut the tube as perpendicularly as possible to the tube axis. (Use tube cutter TK-1, 2 or 3.) Then push the cut tube in until it comes to the flare edge, and tighten the nut by hand. Further, give nut an additional 1 turns with appropriate wrench or the like.Leave 0 space between the screwed-in nut and the tube in-line with the tube axis.
Mount the marker (EX600-ZT1) into the marker groove as required. 4 Marker groove Groove for an identification marker. ST(M) Red flashing 5 MAC address label Displays the 12 digit MAC address which is different for each SI unit. Safety Instructions 6 Valve plate mounting hole Holes for fixing the valve plate. Internal communication error between SI unit and I/O unit is detected.
Mount the marker (EX600-ZT1) into the marker groove as required. 4 Marker groove Groove for an identification marker. Fast Start Up MRP System Redundancy S2 Web server 5 MAC address label Displays the 12 digit MAC address which is different for each SI unit.
Do not use in such an environment where water or oil is splashed. Since it is the open type construction, if water or oil make an ingress into the internal parts, the electric circuit will be corroded and may result in malfunction or damage. 3. Never use switch in an environment where flammable fluid or gas is used.
[F82] Input of line name No name [*] Flow (Temperature) Setting Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. [F90] Setting of all functions OFF Temperature lower limit exceeded The fluid temperature is below -10 oC. Rise the fluid temperature.
Do not use for power transmission These products are not designed to be used as bearings for transmitting power from a drive source, such as a motor. Such use may lead to rotation faults, or damage. Piping Caution 1.
An injury or failure can result. Copy function Input the Set value of accumulated output Input the Set value of instantaneous output Never mount the product in a location that will be used as a foothold. Power and output connector Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Set as above. Troubleshooting Front protective cover (option) Warning Error indication Function Setting Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Error name Error display Error type Troubleshooting method The flow has exceeded the upper limit of the display flow range. Reduce the flow.