C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
Number of auto switches C Single clevis type Cylinder 2 pcs. Nil D Double clevis type J Nylon tarpaulin S 1 pc. T Center trunnion type Rod boot K Heat resistant tarpaulin n "n" pcs.
(mm) A B C D E F G H J L Port size Bracket part no.
P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this Regeneration C option terminal. D Connect the control circuit power supply.
Program Top entry Side entry U S * For "C" type manifolds only * For "C" type manifolds only * For use with 24VDC valves only.
Red LED is ON (C/Q or P24) (When diagnostics is valid) Check the parts showing an error using the LED display or via the Web server. Re-wire the short-circuited part or check if the cable, IO-Link master device or IO-Link device are normal. Short circuit of L + power supply or C/Q terminal or P24. 4 L#B1 Turn off the power to the unit and then turn it on again.
Even for the built-in contact protection circuit type (D-A34[A][C], DA44[A][C], D-A54/A64, D-A59W, D-B59W), use the contact protection box when the wiring length to load is very long (over 30 m) and PLC (Programmable Logic Controller) with a large inrush current is used.
Stainless Steel (mm) A B C D E F G H J L Bracket part no.
4 C-9 MYM50-15AK0502 GMY50 MC-16 P44 C-4 C-11.2 MYM63-15AK0503 GMY63 MC-20 P53 C-4 C-14 GMY20 GMY16 GMY25 GMY32 MYB20-15-A7164 MYB16-15-A7163 RCS-8 RCS-10 P16 P12 TMY-25 TMY-32 5.1 x 3 x 1.05 4 x 1.8 x 1.1 7.15 x 3.75 x 1.7 8.3 x 4.5 x 1.9 7 x 4 x 1.5 7 x 4 x 1.5 C-6 C-7 MYMK-20-stroke Side seal assembly Polyurethane MYMK-16-stroke MYMK-40-stroke MYMK-25-stroke MYMK-32-stroke Note) Two
This is the same concept representing the easy to run through as sonic conductance C (effective area). (3) Formula of flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q :Air flow rate[dm3/min(ANR)], dm3 (
N.C. and N.O. common 2 x Rc (d) Removal dimension G INLET INLET B C E (F) B N COM. N.O. N.C.
For example, if 0.1 C is set here, the actual reference temperature for control is lower than the indicated SV by 0.1 C. 3.3.3 Pump Capacity This symbol warns you of potential burns. Fluid: Water 0.18 Allowable operating range 0.16 Item Spec.
When closed 8.8 When open 22.8 7 Standard Type/Series MHZ2 Finger Position/Options Side Tap Mounting Type [1N1] Through Hole in Opening/Closing Direction [2N2] 4-MM Attachment mounting thread C C B A 4-H Attachment mounting hole S S O O B A Unit: mm Unit: mm Model A 3 4 5 6 Model A 3 4 5 6 B 5.7 7 9 12 C 2 2.5 4 5 MM M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 B 5.7 7 9 12 H 2.9 3.4 4.5 5.5 1
Auto switch mounting surface Bore size (mm) 12 16, 20, 25 32, 40, 50 63, 80, 100 Port side Port side Port side Port side C A C A C A C A B B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides Port, A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 2 kinds of auto switch
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5
ZS-28-C-1 Panel mount adapter With M3 x 8 l (2 pcs.) ZS-27-C Panel mount adapter Panel mount adapter + Front protective cover With M3 x 8 l (2 pcs.)
D C NT-12 NT-16 125, 140 160 M30 x 1.5 18 46 53.1 44 M36 x 1.5 21 55 63.5 53 H B 12 Series CLS Accessory Dimensions Single/Double Knuckle Joint Mounting H A (mm) 3.5 Applicable knuckle joint part nos.
Stations 1 station MADE IN JAPAN C US TYPE1 R EX500-IE1 (PNP) 1 24VDC/60mA/IP65 8-point integrated type, M8 connector, PNP specifications C US TYPE1 R EX500-IE1 (PNP) 24VDC/60mA/IP65 TYPE1 EEX500-IB1-M6 1 set EX500-IE1 4 sets EX500-IE3 2 sets 24VDC/60mA/IP65 MADE IN JAPAN C US TYPE1 R EX500-IE1 (PNP) MADE IN JAPAN C US TYPE1 8-point integrated type, M8 connector, NPN specifications R MADE