Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: 4 pcs., Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m Lead Wire), Number: 2 pcs.
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: J (Nylon), Stroke B: 0400 (4"), Cushion B: Both Ends, Rod Boot B: J (Nylon), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl.
Based on dynamic performance test, JIS B 8419-2010 (Coil temperature: 20[oC], at rated voltage). Note 5) The characteristics are satisfied when tested for 2 hours in each of the X, Y and Z directions at 10 to 500 Hz without energization (Initial value).
B [mm] 11 S coupler KK4P-03MS 35.7 H06 Metric size One-touch fitting 6 KQ2H06-03AS 13 H08 8 KQ2H08-03AS 13 H10 10 KQ2H10-03AS 18.4 H07 Inch size One-touch fitting B B 1/4" KQ2H07-36AS 13.4 H09 5/16" KQ2H09-36AS 13.4 H11 3/8" KQ2H11-36AS 18 With S coupler plug mounted (KK4P-03MS) With One-touch fitting mounted (KQ2H AS) -3- 4.External dimensions Long nozzle(Option) L + 7 Reference dimension
Membrane Air Dryers 361 405 428 468 548 618 83 187 53 113 212 54 1/4 73 140 40 Port size L B A Port size L A B C 70 91 3/8 1/2 3/8 IN Port size: 1/4 OUT Port size: 1/4 IDG30, 30L IDG50, 50L IDG60 IDG75, 100 IDG60L, 60S IDG75L, 75S IDG100L, 100S Model Model (67) (46) (26) IDG3, 5 IDG10 IDG20 Width across flats 17 Width across flats 14 Width across flats 14 Purge air outlet for dehumidification
CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection. When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch.
The proof pressure is double the operating pressure range. -28No.LFE*-OMZ0012 Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow [L/min] Model B Minimum Maximum A LFE1 0.5 20 LFE2 2.5 100 Flow rate 0 Minimum Maximum rated flow LFE3 5 200 rated flow Out of range -29No.LFE*-OMZ0012 Dimensions 2XPort size Note) The electrical
Note 2) Operation is possible with a valve with small Cv value when the operation cycle is small. 12 How to Order P B 1 3 1 3 A S Female thread / Tube extension P B 1 3 1 3 A S With nut Port size Material of diaphragm Symbol Main fluid Pilot air Symbol Material of diaphragm connection size connection size Female thread 1 PTFE 01 Rc 1/8 N01 NPT 1/8 F01 G 1/8 Actuation Tube extension Symbol
For safety operation of SMC Refrigerated Air Dryer, read thoroughly and follow stated safety instructions, as well as regulation stated within ISO 4414*1 & JIS B 8370*2. *1) ISO 4414: Pneumatic fluid power General rules and safety requirements for systems and their components *2) JIS B 8370: Pneumatic fluid power General rules relating to systems This manual explains about installation
thread piping With drain guide AF800 AF900 409 489 440.5 520.5 393.5 473.5 410 490 406.5 486.5 Push button B (With auto-drain) Model A B C D N.O N.C E AF800 AF900 150 200 410 490 33 46 140 170 439 519 440 520 200 260 Precautions Be sure to read before handling.
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
B and H cannot be selected at the same time. The current bracket cannot be used for this product. Note 2) Assembly of a bracket and set nuts. Note 3) See pressure unit table below.
Action Head cover type N E F Y Rubber bumper V V V V Auto switch mounting type*1 A Rail mounting B Band mounting Cylinder stroke [mm] Refer to the next page for standard strokes. Mounting bracket*1 Made to order For details, refer to page 3.
The symbol refers to surface finishing of JIS G 4305 cold rolled stainless steel sheet. 47 B
Magnet: None, Mounting: F (Front Flange), Bore Size: 400 (4"), Stroke A: 1000 (10"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0200 (2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: S (Side Lug), Bore Size: 400 (4"), Stroke A: 0300 (3"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0300 (3"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 400 (4"), Stroke A: 0150 (1 1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0000, Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XB5C11 (Oversize Rod, Dual Op. Sgl. Rod)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 400 (4"), Stroke A: 0250 (2 1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0000, Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XB5C11 (Oversize Rod, Dual Op. Sgl. Rod)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 400 (4"), Stroke A: 0250 (2 1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0250 (2 1/2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XB5C11 (Oversize Rod, Dual Op. Sgl. Rod)