*The D-A9ll/M9lll auto switches are shipped together, (but not assembled).
) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 700 800 900 Flow rate (l/min (ANR)) Inlet pressure (MPa) 7 Direct Operated Precision Regulator/Modular Style Series ARP20/30/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e C SM 2 OUT A A IN OUT t A-A BLEED w y Note Component Parts
) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 100 200 300 400 500 600 700 800 900 Flow rate (l/min (ANR)) Inlet pressure (MPa) 7 Direct Operated Precision Regulator/Modular Style Series ARP20/30/40 Construction ARP20(K)/30(K)/40(K) ARP20K/30K/40K (With backflow function) r q 1 I N e C SM 2 OUT A A IN OUT t A-A BLEED w y Note Component Parts
CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.
die-casted Hexagon bolt Stainless steel C B D Width across flats PAT. 7 A Freeze reduction type/Option VCHNF Sleeve guide Resin Sleeve Copper tubing -06 to 14 3 4 AN VCHN (mm) AMC Model Port size (R) A B C D Mass (g) VCHN3-06 VCHNF3-06 VCHN3-10 VCHNF3-10 VCHN4-10 VCHNF4-10 VCHN4-12 VCHNF4-12 VCHN4-14 VCHNF4-14 3/4 200 72 74 41 590 AMV 3/4 200 72 74 41 710 1 200 72 74 41 605 AMP 1 200 72
D-DN This catalog is printed on recycled paper with concern for the global environment. Series 10-V100 Rubber seal 3 port direct operated solenoid valve Specifications Air Fluid Ambient and fluid temperature (C) 10 to 50 (With no freezing. Refer to page 714.)
Bit 3 of SW2 SW1 Station Address Bit 3 of SW2 SW1 Station Address OFF 0 Disabled ON 0 50H OFF 1 41H ON 1 51H OFF 2 42H ON 2 52H OFF 3 43H ON 3 53H OFF 4 44H ON 4 54H OFF 5 45H ON 5 55H OFF 6 46H ON 6 56H OFF 7 47H ON 7 57H OFF 8 48H ON 8 58H OFF 9 49H ON 9 59H OFF A 4AH ON A 5AH OFF B 4BH ON B 5BH OFF C 4CH ON C 5CH OFF D 4DH ON D 5DH OFF E 4EH ON E 5EH OFF F 4FH ON F 5FH Turn the power
If using straight entry piping type, the material of piping and tubing need to be taken into consideration when deciding panel cut-out spacing. -83No.PF-OMO0005-F Bracket (ZS-33-M) Bracket (ZS-33-MS) Lead wire with connector (ZS-33-D) -84No.PF-OMO0005-F Revision history A: Modified errors in text. B: Revision. C: Contents revised in several place. D: Contents revised in several places.
Min. to Max. a to b c to d PF3W7 oC Common 0 to 100 -10 to 110 0 to 1000 -100 to 1100 : The flow ranges and relationship between the fluid and PD are shown in the figures below.
B N.O. 1/2 G 15 With surge voltage suppressor C 110 VAC Stainless steel D 200 VAC 5 20A H C37 N.C. 3/4 20 E 230 VAC C N.O. J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.
LEY25: 200 or less LEY32: 100 or less 3. In case of [Double clevis], use the actuator within the following stroke limit. LEY16: 100 or less LEY25: 200 or less LEY32: 200 or less 4. G Head flange is not available for LEY32. Nil 1 3 5 8 A B C Without cable 1.5 3 5 8 !
B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.
D E F G H J K L M N P Q R S T U V W 65A 5 100 VAC Grommet Flange type with surge voltage suppressor 110 VAC A B C D Direct piping type 200 VAC Flange type 230 VAC 80A 6 Flange body I type 24 VDC Flange body II type 24 VDC DIN terminal with surge voltage suppressor 100 VAC 7 8 90A B Flange type 110 VAC 100A 200 VAC 230 VAC 24 VDC Conduit terminal 100 VAC with surge voltage suppressor 110 VAC
IC Electroless nickel plated Dimensions VBA Caution F A Model ARJ1020F-M5-04 B 10.4 C 4 D E G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
to 2000 200 to 300 15 200 to 2000 200 to 300 20 150 to 2000 150 to 250 30 50 to 2000 50 to 200 60 50 to 2000 50 to 150 (Note) After installation, verify the effects of static neutralization.
AD value C Communication speed The speed at which the fieldbus sends and receives data. It depends on higher-level equipment (PLC, etc.) and is measured in bps (bits per second). Current consumption The current necessary to operate each unit. D Diagnosis Information Consists of the standard diagnosis information defined by PROFIBUS DP and the diagnosis information unique to the product.
Fieldbus interface connector BUS OUT/Port2: M12 4 pin socket D-coded (Port type: MDI-X) No. Designation Content 1 RD+ Receive Data + 2 TD+ Transmit Data + 3 RDReceive Data 4 TDTransmit Data BUS IN/Port1: M12 4 pin socket D-coded (Port type: MDI) No. Designation Content 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data Fig. 2-1.
E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
E C E E (KF flange) (K flange) Fd Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLF-16-2 40 108 38 20 30 17 44 XLF-25-2 50 121 48 27 12 40 26 44 XLF-40-2 65 171 66 39 11 55 41 67 XLF-50-2 70 185 79 46 11 75 52 72 XLF-63-2 88 212 100 55 11 87 95 70 76 XLF-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMV0017 6.