200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Ex. 1) To detect 300 m, select a 1.0 detection nozzle and supply pressure of 0.2 MPa.
Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 1 2 10 20 Thread type VC Rc G NPT Nil F N Material VDW C S C37 SUS Type 30 VQ VVCW20-4A OUT port size Stations Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 VX2 VX Type 10 is M5 only.
Grounding should be to a D-class ground. (Ground resistance of 100 or less.) 3. Grounding should be performed near the actuator to shorten the grounding distance. 4. The cross-sectional area of this wire shall be a minimum of 2 mm2. 5. Avoid common grounding with other devices.
PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V Current output 2.4 mA 4 mA 20 mA 21.6 mA Be sure to connect to a flow sensor with a temperature sensor. -70No.PF-OMN0012-H Dimensions Front protective cover + Panel mount adapter -71No.PF-OMN0012-H Cut-out dimensions for panel mounting : The
C a u t i o n The shape of the rod end to be inserted into the lock unit should be like those shown below so that the lock unit seal and inner surfaces are not damaged. Chamfer Chamfer (1) For male thread (2) For female thread 30 30 D-2 D-2 D D Fig. 2 Rod end style Do not apply excessive lateral load or external force to the lock unit. They may break the lock unit.
7 A*8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J (
flats C G E H B NN Effective thread length T (R) NA Q N F NA I F N CC 0.1 + 12-CY3B50, 63 12-CY3B6 to 15 (mm) B 17 25 35 36 46 60 70 86 100 0.007 0.043 30 32 CC 32 38 D 7.6 12 16.6 21.6 26.4 33.6 41.6 52.4 65.4 E 4 1.5 2 2 2 2 3 8 8 F 8 9 10 13 13 16 16 2 2 G 5 5 5.5 7.5 7.5 8 11 14 14 H 13.5 12.5 13 20 20.5 22 29 33 33 I 28 34 40 50 58 72 J 4.5 4.5 6 6 8 8 10 12 12 N 9.5 11 11 18 18.5 20
Product Profile: ISO Standard Solenoid Valve: Size 1, 2 Rubber Seal Series VP7-6/7-8 Solenoid valve conforming to ISO standard Size (1)/VP7-6 Size (2)/VP7-8 (Rubber seal) Single solenoid (FG-S) Double solenoid (FG-D) Reverse pressure (YZ-S) Reverse pressure (YZ-D) 2 position 3 position Closed center (FHG-D) Exhaust center (FJG-D) Double pilot check (FPG-D) Pressure center (FLG-D) Courtesy
d C C B H B H Material: Carbon steel Material: Carbon steel Part no.
Description 1 DC (+) 18 6.5 2 N.C. 24 Supply port ISA3-C: Rc1/8 ISA3-F: G1/8 1 Detection port ISA3-C: One-touch fitting ISA3-F: G1/8 1 3 DC () 36 4 OUT1 Unit: mm 1: Conforming to ISO1179-1 Stations 1 2 3 4 5 6 (49) 47 L1 38 76 114 152 190 228 18 2 Piping type C (4 One-touch fitting) C (6 One-touch fitting) F (G thread) H 13 13.6 19 ISA3-mm (DIN rail mounting) 2 1 3 1.8 L1 (23) 7 (41.1) 38
Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
Analog output Range Rated pressure range A B C For vacuum 0.0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 to 100 kPa -100 kPa 100 kPa For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13No.PS-OMG0004-D Dimensions PSE54(A)M3 M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004
TMH Electroless nickel plated ASD Easy to use AS Larger knob Push-lock type AS-FE Easy to lock KE Body size D [mm] 1 9.4 Unlock Lock AS-FG D 2 12 (Port size 1/8) AS-FP 13 (Port size 1/4) 3 16.6 AS-FM 4 18.8 AS-D AS-T ASP ASN AQ ASV Improved tube insertion/removal AK Max.
Leakage voltage Take special precautions if a resistor is used in parallel with the switching element or a C-R element (for surge voltage protection) is used for protection of the switching element. The valve may fail to turn off due to leakage current flowing through the resistor or C-R element. PF2 IF Data Switching element OFF Caution R C Leakage voltage Power supply 1.
Vacuum port pressure range: 101 kPa to 0.6 MPa
(c) COM A byte (d+3) byte (b+2) Word(c+1) COM B byte (d+5) byte (b+4) Word(c+2) COM C byte (d+7) byte (b+6) Word(c+3) COM D : : (c, d=0 to) NOTE Read carefully the user manual of PLC which is used as a master.
IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PV D-M9P DC24V DC12V Relay PLC 2-wire D-M9BV D-M9B DC24V DC5V,12V 3-wire (NPN) D-M9NWV D-M9NW DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PWV D-M9PW Yes Grommet DC24V DC12V Relay PLC 2-wire D-M9BWV D-M9BW DC24V DC5V,12V 3-wire (NPN) D-M9NAV D-M9NA DC24V IC circuit Relay PLC 3-wire (PNP) DC5V,12V D-M9PAV D-M9PA DC24V DC12V Relay PLC
Without D-sub connector D-sub connector entry With D-sub connector With robot cable Without D-sub connector D-sub connector entry With D-sub connector With robot cable Nil Robot adapter Applicable shaft diameter 8 10 11 AHC unit 14 15 20 24 25 M3 M5 Tool adapter Port MA310 1 MA320 1 MA210 Electric specifications Without D-sub connector Without D-sub connector D-sub connector entry With D-sub
3 ISE30A -0.11 MPa Y ZSE30A 0-101 kPa ZSE30AF -100100 kPa K T 2 01 R1/8(M5) N01 NPT1/8 (M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3 C C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L
Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -92No.PF-OMX0002-B Characteristics data Flow rate/ Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A703H 30