Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric

Part Number Description: MOUNTING NUT (CZ1D15*)   Product Line: A   Product Line Description: ACTUATOR   Family Code: 426   Family Description: CZ ROUND BODY CYLINDER   Class Code: G2   Part Code: 2   Reference Code:  K   This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number

The specialty regulator series VBA is a booster regulator that saves money and energy by increasing the main line pressure up to two times. The booster regulator, when connected to air supply line, increases pressure up to two times and the main air supply pressure may be set low. Desired pressure increase can be easily adjusted. Boosts local line pressure without requiring additional power

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Flow Rate Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)

Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Option 1: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket), Calibration Certificate: A (Yes)

Body Size: 40, Filter Type: D (Antibacterial Filter + Antibacterial Filter + Odor Removal Filter + Bacteria Removal Filter), Thread Type: F (G), Port Size: 04 (1/2), Flow Direction: R (Right to Left)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal. Temperature

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature

Body Size: 44 (AC40-D), Thread Type: F (G), Port Size: 04 (1/2), Body Type: 1 (Front and Back Port Selectable)

Body Size: 54 (AC40-06-D), Thread Type: F (G), Port Size: 04 (1/2), Body Type: 1 (Front and Back Port Selectable)