SMC Corporation of America
Elite Part Number Search
Search Results "AL20-01-C-A"

Stations PFA Port size Orifice diameter 1/4 3/8 1/2 Valve type Symbol Type 4 8 12 Manifold P P Stations are counted from station 1 on the left side, with the A (OUT) ports in front. A A N.C. A (OUT) port A Non-locking Locking A LLH2A-03-02-C 1 set 1 set Manifold base part no. LVH20A-02-C 2 sets 2 sets Valve part no. (stations 1 & 2) LVH20AL-02-C 1 set 1 set Valve part no.

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. -27- Recommended Parameter Values [LEY] LEY25/LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.

1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective area

steel 25, 32 only 55 19 Steel ball A Carbon steel Cushion seal A Urethane 56 20 Same as cushion seal A except for 20, 25 standard strokes Steel ball B Carbon steel 21 Cushion seal B Urethane 57 Tooth ring Stainless steel 22 Damper Urethane Cushion ring gasket A NBR 58 23 Same as cushion ring gasket A except for 20, 25 standard strokes C type snap ring for taper ring Carbon steel 24 Cushion

Key Position and Rotation Range Single vane type Double vane type 90 180 270 90 n o r ti n a r o a a ti n n a g n o t r g a ti o t n e a e o g t r o r e 2 1 r y y 7 9 8 y e e 0 0 e Key 0 K K K + 4 0 + 4 0 + 4 0 + 4 0 Key Key (45) 0 9 Standard Option Key e g n a r n o ti a t o r (90) y e K (45) (45) A port B port A port A port A port B port B port B port 100 190 280 100 n r a o n r a o

Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. 4.

Please change the parameter in the initial setting. * For LECSS2-T, please set the electronic gear with PC, PLC etc. in your application. -24- Recommended Parameter Values [LEY] LEY25T6 LEY25DT6 LEY32T7 LEY32DT7 / LEYG25T6 / LEYG25DT6 / LEYG32T7 / LEYG32DT7 Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Initial value Recommended value Parameter *1,*2 Para.

C U U M E J E C T O R D I M E N S I O N S W I T H VA LV E A N D VA C U U M S W I T C H W I T H V A LV E S A N D S W I T C H (N)ZM HK5LZ V O LTA G E 5 24VDC 6 12VDC N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm V A C U U M S W I T C H Nil Without E15L Solid State (NPN) E55L Solid State (PNP) M21L Reed M15L Non-Contact S Y S T E M C I R C U I T Supply Exhaust P O R T T H R

When closed 8.8 When open 22.8 7 Standard Type/Series MHZ2 Finger Position/Options Side Tap Mounting Type [1N1] Through Hole in Opening/Closing Direction [2N2] 4-MM Attachment mounting thread C C B A 4-H Attachment mounting hole S S O O B A Unit: mm Unit: mm Model A 3 4 5 6 Model A 3 4 5 6 B 5.7 7 9 12 C 2 2.5 4 5 MM M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 B 5.7 7 9 12 H 2.9 3.4 4.5 5.5 1

Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.

Circuit Diagram : D-90Type Bore Dimension A j Dimension B Dimension C ;t)-k.

Fittings & Tubing Air Cylinders Rotary Actuators BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band Band

0 2(A) 1(P) r o e !3 !1 !2 !3 e o r !0 i !1 !2 2(A) 1(P) Actuated Actuated 2(A) 1(P) 2(A) 1(P) Component Parts No. Description Material Note 1 Valve PBT 2 Valve sheet A PBT 3 Valve sheet B PBT 4 Valve sheet C PBT No.

fitting 8 (5/16") one-touch fitting 1/4" one-touch fitting Output specification A B C D E F G H 2 NPN outputs 2 PNP outputs 1 NPN output + Analog (1 to 5 V) 1 NPN output + Analog (4 to 20 mA) 1 PNP output + Analog (1 to 5 V) 1 PNP output + Analog (4 to 20 mA) 1 NPN output + External input Note 3) Piping entry direction Straight Bottom Nil L Different combinations of piping entry directions

Analog Output Flow rate/Analog output Fluid temperature/Analog output A B B Output Output A C Voltage output 0.6 V 1 V 04/20/40 11 21 C D C Current output 2.4 mA 4 mA 1 V 1.5 V 6 mA 1.4 V 5.6 mA 1.5 V 5.9 mA 5 V Voltage output 4 mA 20 mA Current output C D The values of B vary according to the range.

Auto switch mounting surface Bore size (mm) 63 32, 40, 50 Port side Port side C A C A B B Auto switch mounting surface Auto switch mounting surface Port, A, B, C sides Port side A, B, C sides Auto switch type qBQ-2 wBQ2-012 Two kinds of auto switch mounting brackets are used as a set.

Symbol Model S T U V W PF2MC7501/7102 24 22 32 40 50 PF2MC7202 30 30 42 48 58 -99No.PF-OMZ0002-A Lead wire with M8 connector (ZS-40-A) M12-M8 conversion lead wire (ZS-40-M12M8-A) -100No.PF-OMZ0002-A Revision history A: Contents revised in several places.

When a surge-generating load, such as a relay or solenoid valve, is driven directly, use a product that incorporates a surge absorption element. 9 - Caution Conduct the following inspection before operation. a) Confirm that the power supply line and each signal line is not damaged. b) Play and looseness of the connector to each power line and signal line c) Play and looseness of the mounting

Bracket ZS-30-A With M3 x 5L (2pcs.) Connector for PSE300 ZS-28-C 1pc. A Note) The bracket is unassembled in the factory, but is included with the shipment.

Operation < Valve opened > When the coil u is energized the opened pilot A closes, the pressure in the pressure action chamber B rises and the main valve C closes. < Valve closed > When the coil u is not energized, the closed pilot valve A opens, the pressure in the pressure action chamber B drops and the main valve C opens.