SMC Corporation of America
Elite Part Number Search
Search Results "10-MGF40-50"

Port size Port size Body size Body size Port size Port size Bowl Symbol Symbol 30 40 50 60 20 30 40 50 60 Applicable model AF20 to 60 Symbol 2 Note 4) Description 02 03 04 06 10 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 Bowl Metal bowl Applicable model AF30 to 60 Description Symbol Metal bowl with level gauge 8 Note 3) AF30 to 60 2 Note 4) Metal bowl Note 4) Only Metal Bowl

(OUT05)OFF 11INPOFF ... 12BUSY ON 0mm 50mm 60mm 100mm 5 13DRIVEOFF 14No.2 ON (OUT1ON) 15INPON 16BUSYOFF 10mm 57 - 13.2 100mm/s 100mm (No.1 ) 100mm ,10mm/s 50% 5mm (INPON )50mm/s 50mm (No.2 ) No. 1 2 2 2 mm/s mm mm/s mm/s mm mm mm mm/s 0 1 ABS 100 100.00 1000 1000 50 40 10 100 0 0 5 2 ABS 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () 1No.1(IN0ON) / 2DRIVEON (2)(5)(10)(13) No.1

Product weight [kg] Model Stroke Additional weight Size Motor type 50 100 150 with lock 16 S2 1.96 2.35 0.20 25 S3 3.86 4.43 5.83 0.40 -5- LESYH*(D,R,L)*T6/T7 Motor type T6/T7 Model LESYH16*T6 LESYH25R/LT7 LESYH25DT7 Parallel In-line Stroke[mm] 50,100 50,100,150 50,100,150 Horizontal 8 12 12 Max. work load [kg] Vertical 6 12 10 20 10 20 Force [N](Set value: 12 to 24%) *1 65 to 131 127 to

Intermedial e stroke between 50-100 (55, 60, 65. ). are obtained through the use 01 spacers (5, 10. I S, 2Omm) (Example) CDOBPSo-55 OM: SMC would install a 2Qmm width spacer in the C002BP 50-750M. Not.. No. Auto Switch Mounting Bracket Part No. AutoPart Specifications Auld ..

Valve size 16 25 40 50 63 80 Bellows assembly u XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 XL1A63-2-101 XL1A80-2-101 Nut assembly o XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 XL1A80-10-1 Bellows assembly * Bellows assembly includes the valve seal 1 (Standard material: FKM).

(Refer to Model Selection on page 6.) 50 10 10 CY 20 3 4 5 3 4 5 10 YES Load weight (kg) Load weight (kg) Load weight (kg) 10 Load weight (kg) MQQ M 5 4 3 NO Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 2 Can the positioning be adjusted by the re-try function

(Refer to Model Selection on page 6.) 50 10 10 CY 20 3 4 5 3 4 5 10 YES Load weight (kg) Load weight (kg) Load weight (kg) 10 Load weight (kg) MQQ M 5 4 3 NO 2 2 Can the positioning be adjusted by the re-try function without oversteps plus side? Due to fluctuation of speed, etc, Stroke reading cylinder with brake may overrun beyond the set position.

4 20, 25, 32, 40 AS221FG-02 AS331FG-02 R(PT) 1/4 40, 50, 63 AS321FG-02 AS331FG-03 R(PT) 3/8 40, 50, 63 AS321FG-03 AS431FG-04 R(PT) 1/2 63, 80, 100 AS421FG-04 AS131FG-U10/32 10-32UNF 6, 10, 16, 20 AS121FG-U10/32 AS231FG-N01 NPT1/8 20, 25, 32 AS221FG-N01 Elbow type AS231FG-N02 NPT1/4 20, 25, 32, 40 AS221FG-N02 AS331FG-N02 NPT1/4 40, 50, 63 AS321FG-N02 AS331FG-N03 NPT3/8 40, 50, 63 AS321FG-N03

Part No.: SFB100-02X8 002 Part No.: SFB200-02-S -X40 V Specifications Fluid Air Nominal filtration Operating pressure Max. 0.99 MPa Nominal filtration m Note 1) Rated flow rate L/min (ANR) Note 2) Symbol 001 002 005 010 020 040 070 100 Max. operating temperature 80C O-ring 1 2 5 10 20 40 70 100 5 10 15 30 50 80 130 250 Element proof differential pressure Symbol N V T Material NBR FKM PTFE

Applicable pressure sensor PSE531 PSE541 PSE561 PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) pressure range 5%R.D.

14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31 32.9

Option R . 10-1 10.1 Safety instructions for use . 10-1 10.2 Specifications. 10-1 10.3 Connection of power supply . 10-2 10.4 Handling Precautions of the Earth Leakage Breaker . 10-2 10.5 Electrical circuit diagram . 10-2 Chapter 11 Inspection record . 11-1 11.1 Inspection record . 11-1 IDF190D/240D Series IDX-OM-Y002 Chapter 1 Safety Chapter 1 Safety 1.1 Before Using the Air Dryer Before

90 5 90 10 180 10 90 5 90 10 180 10 90 5 90 10 180 10 90 5 Air (Non-lube) Fluid 1.05 1.5 Proof pressure (MPa) 5 to 60C Ambient and fluid temperature 0.15 to 0.7 0.2 to 0.7 0.15 to 1.0 Operating pressure range (MPa) Rotation time adjustment range (sec/90) 0.07 to 0.3 Allowable radial load 40 N 50 N 60 N 20 N 30 N 60 N 80 N 15 N Shaft load Allowable thrust load 2 15 N 30 N 40 N 10 N Allowable

YES Hysteresis mode OFF n_1 n_2 Large pressure and vacuum pressure [n] H (Fix hysteresis) = 3 digits H H ON Window comparator mode NO OFF n_1 n_2 Large pressure and vacuum pressure 3 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Example of Internal Circuit and Wiring ZSE F/ISE --22(L)-(M) 50 60 50 60 ZSE F/ISE --30(L)-(M) 50 60 50 60 With analog output

Operator Buna N 10 Recssed Non-Lockihg OPeralor PB 0103 61 l Scrws' Pilot Covers (4) Hold Down Bolt (8.32 x 1 Y'!')

MPa Supply pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.

Composed effective area So (mm2) 6 2000 h=0.7 10 1/4, 3/8 7.5 2500 REC 0.5 10 10 1/4, 3/8 0.1 0.3 9 3000 RHC 6 1/4, 3/8 2.5 500 8 1/4, 3/8 MTS 5 1000 0 1,000 2,000 3,000 25 (1/4) 10 1/4, 3/8 Max. speed Vmax (mm/s) 7.5 1500 CC Graph 3:32 10 1/4 10 2000 12.5 15 2500 3000 30 1/4 1/4 h=0.7 6 10 1/4, 3/8 20 4 500 0.5 0.1 0.3 10 32 (3/8) 10 1/4, 3/8 8 1000 0 1/4, 3/8 3/8 3/8 3/8 12 16 20 24 1500

Symbol O.D. thread size Stroke 0805 1006 1410 8 mm 5 mm 2 pcs. 1 pc. 10 mm 6 mm 3 pcs. 1 pc. 14 mm 10 mm 1 pc.

Prefix the part number of the air catch sensor with an asterisk (). 16-8-5 6 Series ISA2 Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa

10 to 60C (No freezing) Cushion None Lubrication Non-lube Piston speed (Clamp speed) 50 to 150 mm/sec Port size (Cylinder port) Rc1/8 * Minimum operating pressure is 0.2 MPa when cylinder part and locking part use the same piping.