SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-Y-P-N02"

6 M1L025-17B82076 C-7 P-6 M1L040-17B82078 C-9 P-8 4.7-10 Series ML1 Auto Switch Specifications Refer to p.5.3-2 for the details of auto switch.

Trace the discharge rate, 6 L/min, up to the point between the discharge curves for SUP = 0.3 MPa and 0.4 MPa, then trace to the Y-axis, finding the air consumption to be around 55 L/min (ANR). PA(P) PAX PB Caution 1. These flow rate characteristics are for fresh water (viscosity 1 mPas, specific gravity 1.0). 2.

E P.450 to 457 AV AF Made to Order 0.4 MPa Setting (-X406) The maximum set pressure is 0.4 MPa. When a pressure gauge is included, the display will show a range from 0 to 0.7 MPa. q P.456, 457 0.85 MPa Setting (-X2068) The maximum set pressure is 0.85 MPa.

1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !4 Open condition Component Parts Note Note No. q Description Material No. Description Material Bushing B !0 o Body Hard anodized Aluminum alloy Sintered alloy steel End plate Stainless steel 10: Stainless steel 16 to 25: Aluminum alloy w Piston 16 to 25: Chromated Bumper !

1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !4 Open condition Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Note Note No. q Description Material No. Description Material Bushing B !

P O Flow Characteristics/Operating Principles P O, O Construction Detail .. PO Dimensions P O Installation PO Power Amp.: Series VEA Model / Spe c i f i c a t i o n s . . . . . P O H o w t o O r d e r . . . . . . . . . P @ Dimensions/ Handling Instructions . . . . . P@, @, @ External Connections P@, @ Features and Functions P@ Sample Applications . . .

P O Flow Characteristics/Operating Principles P O, O Construction Detail .. PO Dimensions P O Installation PO Power Amp.: Series VEA Model / S pec ific ations . . . . P O H o w t o O r d e r . . . . . . . . . P @ Dimensions/ Handling Instructions . . . . . P@, @, @ External Connections P@, @ Features and Functions P@ Sample Applications . . .

SYJ514 With valve 16 4 Multistage Ejector Series ZL Dimensions/Series ZL112 (without Valve) 2-5.4 Mounting hole Scale: 40% Label 50 117 Exhaust with silencer P Standard ZL112 20 V 4.5 166 56 Exhaust port Rc1/2 35 P Port exhaust ZL112P V 14 Vacuum pressure gauge Exhaust with silencer 2-5.4 Mounting hole P With vacuum pressure gauge ZL112-G V Exhaust with silencer Vacuum adapter Rc1/8 2-5.4

OUT1 OUT1 OUT2 OUT2 Refer to p.3.1-8 "Channel selection" for further information. ON YES PHysteresis mode OFF P-1 P-2 > = P Pressure/Vacuum Up H H H (fixed hysteresis) =2% F.S. ON PWindow comparator mode NO OFF P-1 P-2 Pressure/Vacuum Up OUT1 Output mode ON YES OUT2: Same as OUT1. PHysteresis mode OFF n-1 n-2 Pressure/Vacuum Up > = n H (fixed hysteresis) =2% F.S.

P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 OR-1400-178P P: PTFE F: FKM OR-2670-178P P: PTFE F: FKM For VCS30, 40 OR-1717-178P When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .

01 1 station Solenoid on same side of A and B port A port: Rc 1/8 B port: Rc 1/8 Nil P port: Rc 1/8 Thread type R port: Rc 1/8 20 Type S42 Solenoid on same side of A and B port 20 stations Type VK334 Nil F N T Rc S Port size Type VK3140 G P port: Rc 1/8 1 8 01 Rc C6 6 cassette NPT R port: Rc 1/8 NPTF B port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH Type 21: Body ported (A, B port

Calculation Pad W P S t : Lifting force (N) : Vacuum pressure (kPa) : Pad area (cm 2) : Safety factor Horizontal lifting: 4 or more Vertical lifting: 8 or more Horizontal lifting Vertical lifting W = P x S x 0.1 x 1 t This type of application should basically be avoided.

only) (1.0W) K YZ: DIN terminal YOS: DIN terminal without connector Y: DIN terminal YO: DIN terminal without connector (0.5W) Low wattage Y With surge voltage suppressor (2) External pilot R Note 1) Option Note 2) Refer to p.2.10-18 for details about external pilot specification.

Z direction for 2 hrs. each (De-energized) Vibration resistance IZE110-X238 N P N C JQ/T G Impact resistance 100 m/s2 in X, Y, Z directions 3 times each (De-energized) +24 VDC Valve (+) 1 5 Main circuit Material Front case: PBT, Rear case: Denaturated PPE Valve () Not connected 6 2 Weight 50 g OUT 0 V 7 3 Note) Do not use a load that generates surge voltage.

Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R

B Counter bore depth C 4-LD Thread depth M QW PB N A E depth EK Q + Stroke Z + Stroke G A A LW Stroke adjustment screw (inner cover) Note 2) Note 3) Note 2) Operating direction Plug [P (port g)] Plug [P (port h)] P (port a) P (port b) 0.5 0.5 Plug [P (port c)] Plug [P (port e)] Left Right Auto switch mounting groove HI HP H HL HG HT HS HB HA HB HA HG HT HI Note 3) Plug [P (port d)] Plug [

P. 76 KCT Use to branch connection of tubes of both side 90 direction. P. 78 KCL Union Y P. 76 KCU Use to branch connection of tubes in the same direction. 2 branched ports has a self-seal function. Check adaptor P. 77 KCJ Use to add the self-seal mechanism to a usual one-touch fittings, Series KQ. Bulkhead union P. 77 KCE Use to junction connection of tubes for installation of panel.

Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.