Size: 4 [ø25(ø16)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: Rc(PT), Port Size: 25A (1)

Size: 4 [ø25(ø16)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: A (NBR Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 25A (1)

Size: 4 [ø25(ø16)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: B (FKM Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: Rc(PT), Port Size: 25A (1)

Body Size: 1, Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 24VDC, Electrical Entry: DIN Terminal, Light/Surge Suppressor: None, Actuation Type: N.O., Normally Open, Pilot: -, Thread: -, CE Compliant: -

Body Size: 1, Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light/Surge Suppressor: None, Actuation Type: N.O., Normally Open, Pilot: -, Thread: -, CE Compliant: -

Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot)

Size: 4 (ø25), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 25A (1), Voltage: 1 (100VAC 50/60HZ), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)

seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75 or less, Ambient and fluid temperature: metal seal -10 to 50and#176;C; rubber seal -5 to 50and#176;C, .5 METER CABLE, STATION 1,

seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75 or less, Ambient and fluid temperature: metal seal -10 to 50and#176;C; rubber seal -5 to 50and#176;C, 3 METER CABLE, STATION 1,

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or less to 75 or less, Ambient and fluid temperature: metal seal -10 to 50and#176;C; rubber seal -5 to 50and#176;C, 1.5 METER CABLE, STATION 1,

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

END PLATE, VALVE, VV5Q51/55 MANIFOLD, 21, VV5Q51/55 NO SIZE RATING, 2.20261 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LEAD WIRE, VALVE, VV5Q51/55 MANIFOLD, 22, VV5Q51/55 NO SIZE RATING, 0.023 lb

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal

LEAD WIRE, VALVE, VV5Q51/55 MANIFOLD, 22, VV5Q51/55 NO SIZE RATING, 0.0216 lb

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature range (°C): 0 to 90; Output options: NPN or PNP (switch); 1-5V or 4-20mA; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.

Flow ranges (lpm): 0.5-4, 2-16, 5-40, 10-100; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature range (°C): 0 to 90; Output options: NPN or PNP (switch); 1-5V or 4-20mA; Accuracy (flow): ±3% F.S.; Repeatability (flow) ±2% F.S.