Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: P: Individual, EA,EB: Common, Port A,B: Side, Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 7 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: P: Individual, EA,EB: Common, Port A,B: Side, Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 4 Stations, Passage: P: Common, EA,EB: Individual, Port A,B: Side, Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 2 Stations, Passage: P: Common, EA,EB: Individual, Port A,B: Side, Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 10 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: External Pilot, Junction Cover: Separate Junction Cover or None, Stations: 4 Stations, Passage: P and EA,EB: Common, Port A,B: Bottom, Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: P: Individual, EA,EB: Individual, Port A,B: Side, Port Size: 1/8, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 6 Stations, Passage: P: Common, EA,EB: Individual, Port A,B: Side, Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Base Mounted Plug-in w/Multi-connector on D Side, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 4 Stations, Passage: P: Common, EA,EB: Individual, Port A,B: Side, Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 4 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 7 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Base Mounted Plug-in for Serial Transmission, Pilot Type: -, Junction Cover: -, Stations: 9 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: -, Junction Cover: -, Stations: 16 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -
Manifold options include control unit, serial interface unit and a coaxial fitting.Fluid: air, Operating pressure range: 14.5PSI 145PSI, Effective area mm 2 (Cv): 2.7 6.3 (0.15 0.35), Coil rated voltage: 6, 12, 48VDC; 24, 48, 110, 220VAC, Protection structure: dust proof (protection class 0 based on JIS C0920), Ambient and fluid temperature: 14 to 122 F, VALVE, SOL/PILOT 24VDC *LQA, VALVE
Optional auto switches are available.Light weight and compact size, High reliability and long life, Mountable with auto switch, 2 porting variations (top and side), Ball bearing supported shaft, ACTUATOR, ROT, AUTO-SW, ROTARY ACTUATOR, 122 lb