Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 3 (110 VAC (115 VAC) 50/60 Hz), Electrical Entry: DO (DIN Terminal Without Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Bracket Mounting Position: Without Bracket, Auto Switch
Model: 3 (SGC300), Valve Type: 2 (Normally Open), Seal Material: B (FKM), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket on the Left Side
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: B (FKM), Pressure Range: 05 (0 to 0.5 MPa), Thread: N (NPT), Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 3 (110 VAC (115 VAC) 50/60 Hz), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: N (NPT), Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket on the Left
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: N (NPT), Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: W (M12 Connector, 4-pin Type)
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B2 (Bracket on the Right
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: B (FKM), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 1 (100 VAC 50/60 Hz), Electrical Entry: T (Conduit Terminal), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting Position: B1 (Bracket
Model: 3 (SGC300), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 05 (0 to 0.5 MPa), Thread: Rc, Port Size: 20 (3/4), Pilot Valve: Y (0.35 W Type, V116), Voltage: 5 (24 VDC), Electrical Entry: W (M12 Connector, 4-pin Type), Surge Suppressor: Z (With Light and Surge Voltage Suppressor)
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base EX250 type manifold for SV1000 valves, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. "SS5V 05 Station Manifold.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. 0.52 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. 0.45 lb. VVM.
Series: 1 (10-SV1000), Base Type: 10FD, Connector Entry Direction: 1 (Upward), Valve Stations: 05 (5 Stations), P, E Port Location: B (Both Sides, 2-20 Stations), Pilot Type: Internal Pilot, A, B Port Size: C4 (One-touch Fitting for Ø4), Mounting: D0 (DIN Rail Mounting w/o DIN Rail)
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Serial wiring with Input/Output unit, Tie rod base, 3000 series, EX250 type, IP67 protection, Number of inputs/outputs: 32 each, Maximum number of stations: 20 (over 16 requires manifold spec. form) 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base, EX250 type manifold for SV2000 valve, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. 0.52 lb. VVM.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base EX250 type manifold for SV1000 valves, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Tie-Rod Base. VVM.