Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 130mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 50mm, First Stroke: 5mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 100mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 220mm
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 60mm
90 Set pressure 0.4 MPa 100 Flow rate {L/min (ANR)} Flow rate {L/min (ANR)} 80 70 80 60 0.2 MPa 50 60 40 40 30 20 20 10 0.1 MPa 0 2 4 6 8 10 0 0.1 0.2 0.3 0.4 0.5 Number of needle rotations Fluid pressure (MPa) LLB4-1-P1R1VSF: High Flow Type (500 L/min) 500 600 Set pressure 0.4 MPa 0.3 MPa 500 Flow rate {L/min (ANR)} Flow rate {L/min (ANR)} 400 400 300 0.2 MPa 300 200 200 0.1 MPa 100 100
Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch
Series M(D)HR Standard MHR2 2.3-1 SMH03 Nominal size 10, 15 MDHR2 With auto switch Rotary Actuator Size (Torque) Name of CAD file Series Application Page in Vol.3 Standard Copperfree 1 3 7 10 20 30 50 70 100 200 Series/Variation Rotary table Series MSU Standard MSU 1.7-1 SMSUl MDSU With auto switch Rotary table Series MSQ MSQ Standard 1.6-1 SMSQl MSQ With auto switch MSQR With shock absorber
Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)
5 20 10 5 (Pulley ratio 4/7) ratio) Initial value Recommended value Parameter *1,*2 Para.
Option J: With drain guide Bracket (Option) female thread T: With element service indicator Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
5 20 10 5 (Pulley ratio 4/7) ratio) Parameter *1,*2 Para.
Grippers Description Series Bore size Parallel style MHZ2 10 to 40 Parallel style MHZL2 10 to 25 Wide type MHL2 10 to 40 Parallel style MHS2 (2 fingers) 32 to 63 Auto switch mounting screw Parallel style MHS3 (3 fingers)/MHS(L)3 32 to 63 Parallel style MHS4 (4 fingers) 32 to 63 Auto switch Angular style MHC2 10 to 25 1.
Model Cushion Rubber Air Bore size (mm) Action Standard stroke (mm) Auto switch mounting Port size Lubrication Model Relief type Vacuum suction type 10-/21-CJ210 10 15, 30, 45, 60, 75, 100, 125, 150 Double 10-/21-CJ216 16 M5 x 0.8 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Standard Band mounting only acting, Non-lube 10-/22-CJ210 10 15, 30, 45, 60, 75, 100, 125, 150 Single rod 10-/22-
kPa (Detection distance 0.01 to 0.25 mm) 50 to 200 kPa (Detection distance 0.03 to 0.50 mm) Set pressure range 0 to 98 kPa 0 to 0.98 MPa 0 to 101 kPa 100 to 100 kPa 10 to 101.3 kPa 0.1 to 1 MPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 0.1 to 0.45 MPa 0.1 to 0.4 MPa 20 to 101 kPa 101 to 101 kPa 0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa 100 to 100 kPa 0.1 to 1 MPa 0 to 1 MPa Voltage 12 to 24 VDC
10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.
(Values at the initial period) VT325-C VT325-G JIS Symbol Solenoid Specifications Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry Coil rated voltage Allowable voltage fluctuation 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption (3) Note 3) At rated voltage
Note 1: ON/OFF 50 ms flashing Note 2: ON 200 ms single flash, OFF 1 s Note 3: ON/OFF 200 ms double flash, OFF 1 s Note 4: ON/OFF 200 ms triple flash, OFF 1 s Note 5: ON/OFF 200 ms flashing Safety Instructions Installation Setting Troubleshooting Warning General instructions on installation and maintenance Technical documentation giving detailed troubleshooting information can be found on
Clean Exhaust Filter SFE Series RoHS How to Order SFE 11 Size/Port size Male thread type Plug-in type Symbol Port size Max. ow capacity L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. ow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch tting type Symbol Applicable tubing O.D.