Port size Nil N M12 3m lead wire with connector Without lead wire Port size Applicable model Flow rate (l/min) Symbol 4 16 40 100 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Output specification Symbol Nil 1 2 Specification Series PF2W300 Series PF2W200/300 Series PF2W300 Applicable display unit (monitor) model Output for display unit Output
400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 Flow rate l/min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure characteristics
400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F
Features 2 Mechanically Jointed Rodless Cylinder with Protective Cover Series MY1W Slide Bearing Guide Type/Cam Follower Guide Type 16, 20, 25, 32, 40, 50, 63 How to Order Y7BW 300 25 MY1 M W K Number of auto switches Guide type Auto switch type 2 pcs. 1pc. "n" pcs.
/My max. 0.3 Stroke (mm) Stroke (mm) 10 15 20 25 30 5 25 30 10 15 20 5 0.2 MXPJ6 3.5 2.6 2.3 1.4 MXP10 4.2 8.5 1.7 6.3 50 100 200 300 500 700 MXP12 9.8 17 13 4.5 Average speed Va mm/s Collision speed V mm/s MXP16 26 41 28 12 1 Nm = 0.7375 ftlbf Note) Average speed is used at static moment calculation. Collision speed is used at kinetic moment calulation.
Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.
Allowable Moment (Nm) Allowable dynamic moment Allowable static moment Pitching Rolling Yawing LXF Model Load movement direction 4 3 4 a = 1000 2000 a Mep a = 2000 L1 (mm) Pitching Rolling Yawing a = 3000 m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 3 0 1 2 Transfer load m (kg) a = 1000 300 L2 (mm
N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.
pressure MPa (psi) 5.0 (725) Body material Brass, Stainless steel Valve specifications Coil Specifications Seal material PTFE (FKM) Ambient temperature 20 to 100C (-4 to 212F) 184C (363F) or less (PTFE), 120C (248F) or less (FKM) Note 1) Fluid temperature Enclosure Dust proof, Splash proof (equivalent to IP65) Environment Location without corrosive or explosive gases Valve leakage cm/ min 300
V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet:
/ When lubricated, use turbine oil #1(ISO VG32) VH600 Optional specifications VH300 Bottom porting VH410 VH300, 400 Panel mount VH200, 300, 400 VH210 Different P port location* All models 1(P) port is located on handle side.
Possible set range: 60 to 300 sec, at the time of shipping from the factory: 300 sec Timeout error 32.8 ft (10 m) or less Height difference with the customer system side Note 1) This is the space volume of the sub-tank when the liquid level of the circulating fluid is within the specification. Guideline of the recovery volume is 80% of the circulating fluid recoverable volume.
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
LMV10 81023-2A-1 to 4 Note 1) LMV20 Flexible nozzle assembly Copper piping nozzle assembly O-ring 1 1 2 2 81023-31A-1 to 4 Note 1) 123116-2 3 FKM Note 1) Numbers indicate nozzle lengths. 1: 200 mm, 2: 250 mm, 3: 300 mm, 4: 350 mm 1066 LMU100/200 Series Mist Spray Unit Magnet Holder: LMH Series AL800 AL900 How to Order Dimensions ALF ALT LMH 0 1 ALD Magnet holder ALB 2 x M4 x 0.7 Air blow
m 400 1 m 350 Displayed value 300 5 m 250 200 150 100 50 0 0.5 0.4 0.3 0.2 0.1 0 Actual distance [mm] Nozzle Shape Internal Circuit and Wiring Example ISA3-N NPN (1 output) The nozzle shape must be similar to Fig. 1.
800 1250 3100 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 20 25/32 40 50/63 5 Semi-standard/Thread nominal size JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to
air supply Pressure in the tank New New 20 9.2 4 AV2000-A Current model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/min (ANR)] 350 Current model 300
400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after using the FHM-100 for one hour under the following conditions.
Model/Standard Specifications AT Model HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Screw type compressor IDF IDU 110 55 2.2 75 7.5 22 37 Applicable compressor (kW) Reciprocating type compressor Screw type compressor 75 37 2.2 55 7.5 15 22 IDFA 18000 8600 300 12000 1000 3300 5700 (1) Air flow rate l/min (ANR) IDFB Reciprocating type compressor 11000 5600 300 8000 1000 2100 4300 ID Rated performance