How to Order Standard L 40 150 CM2Y L H7BW S 40 150 CDM2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Normal output Flow setting Sets the ON and OFF point of the switch output. 1500 L/min Hysteresis Appropriate setting of the hysteresis will prevent the switch output from chattering. 150 L/min Delay time Delay time of the switch output can be selected. 0.00 s Output ON: Green Display colour Select the display colour.
Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch
Ltd. 18 Hudson Avenue, P.O. Box 581' Castle Hitl, N.S.W.
SUP = 0.2 MPa 150 100 50 1 0 2 3 4 5 6 7 Caution Cycle (Hz) 1. These flow characteristics are for fresh water (viscosity 1mPas, specific gravity 1.0). 2. The discharge rate differs greatly depending on properties (viscosity, specific gravity) of the fluid being transferred and operating conditions (density, lifting range, transfer distance).
Pressure characteristics*4 2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard) Pressure Electrical Power supply voltage 24 VDC 10% Current consumption 150 mA or less Protection Polarity protection Display accuracy 3.0% F.S. Analog output accuracy 3.0% F.S. Accuracy Repeatability Switch output/Display: 1.0% F.S. Analog output: 1.0% F.S. Temperature characteristics 5.0% F.S.
How to Order EX9-FU EX510-DX EX510-DY3 EX510-DY4 10 Applicable model Rated current Rated insulation capacity Fuse resistance value 1 A 5 A Fuse rated current 48 VAC/DC 50 A 0.145 18 m 10 50 1 A 5 A 1721 Series EX510 Ordering Examples Shown is an example for ordering the EX510 series.
150 150 150 320 400 70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 13
150 150 150 320 400 70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 HA AT ID AMG AFF AM Misc. 14-15-3
OUT1 DC1224V DC1224V DC(-) DC(-) Max.80 mA 1.5 V 6815 V 1 k 69420 mA 12 V300 24 V600 Max.30 V80 mA 1 V 2815 V 1 k 29420 mA 12 V300 24 V600 -40No.PF-OMO0007CN PF2A7--28--X560 PF2A7--68--X560 PF2A7--29--X560 PF2A7--69--X560 (15 V) (420 mA) 12 V 300 24 V 600 1 k 5F.S. 1 s A B 1 V 5 V 4 mA 20 mA 1 NL/min 10 NL/min PF2A710 3.5 CFM10 -2 35.0 CFM10 -2 5 NL/min 50 NL/min PF2A750 18
No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
Outer dimensions. 18 2 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Warranty period and guaranteed range The guaranteed warranty period is 100,000 cycles(under SMC endurance test conditions), 18 months after delivery or 12 months in service, whichever comes first. If the specification is not kept, or any non-conformance derived from mounting or replace of a device, an assembly, or an O-ring at your place occurs, the guarantee cannot be applied.
M3x7 0.59Nm 18 - (0.7mm) 19 - 5-3.
Product Weight [kg] Stroke [mm] Lock weight Model 50 75 100 150 8 1.06 1.23 0.16 16 2.39 2.78 0.32 25 4.82 5.42 6.22 0.61 -4- How to order Coution The actuator body and controller are sold as a package. If when only the actuator is purchased separately, confirm that the combination of the controller, which you have and the actuator is compatible.
Discrete Input Assembly instance ID Type Description No. of bytes Product model 17 Input 32 Discrete input Points 4 EX250-SDN1 18 Input 32 Discrete input Points 6 EX250-SDN1-X102 -25No.EX-OME0003-H The data format is shown below.
No.EX-OMK0006-C PRODUCT NAME Fieldbus system SI unit (CANopen compatible) MODEL / Series/ Product Number EX250-SCA1A Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 8 Mounting and Installation 9 Installation 9 Wiring 10 Setting 15 Setting of baud rate (Communication speed) 17 Overview object dictionary for communication object area 18 Overview
(between FE and all accessible terminals) Insulation resistance 10 M or more (500 VDC is given between FE and all accessible terminals) Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2 2 hours for each direction X, Y and Z Vibration
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. Bore size Applicable series 02 03 04 06 10 12 14 20 Note 1) AS800 is available as special.