Flat Finger Type [3] 4-MM thread depth L Attachment mounting thread K J A A D G B D B K J F C S W O Unit: mm Weight g F G Open Closed 2 2.5 3 4 J K MM L B C D Model A W 5.4 7.4 4.45 5.8 7.45 8.9 M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 5 6 8 10 55 115 235 420 5.2 8.3 10.5 13.1 10.9 14.1 17.9 21.8 2.45 3.05 3.95 4.9 6 8 10 12 5 8 10 12 +2.2 0 2H9 2.5H9 3H9 4H9 1.4 1.4 1.6 2 0 -0.2 0 -0.2 0 -
All dimensions in mittimeiers. 26 I Non-Adjustable Hydraulic Series lmperial Accessories sroP BAR (SB) ['l E -T I c __l _ l F --->l nr tdl o&| (n.ll A I ( D T I Boh Sire W.hhi r5&706300 Pll500 5odo5 l s t T 2 i t I 1 . 6 3 l . l l I l l I l l 6 r r f f r l k " D s ? l y t . I 6 . 1 158650300 PM?
Auto Switch Standard D w/Auto Switch (Magnetic Piston) Style Standard Cylinder K Non-Rotating Cylinder W Double Rod M Male Rod Stud Mounting No. of Switches 2 Pieces S 1 Piece n n Pieces B MX0 Basic L MS1 Foot Bore Size 150 1.5 200 2 250 2.5 325 3.25 400 4 For larger bore sizes up to 32 bore.Please consult CAT: N304-EX F MF1 Front Flange G MF2 Rear Flange R MS4 Side-Tapped See Auto
Pin Dd9 2-3 L 4 4 D L Part no.
Operating air pressure Air discharge if no drainage 6 l (ANR) each time 0.3MPa Model Air flow capacity (l/min (ANR)) 50/60Hz IDF2D 120 140 IDF1D 85 100 IDF4D 215 250 IDF3D 180 210 10 l (ANR each time 0.5MPa 50Hz 60Hz 14 l (ANR) each time 0.7MPa Operation cycle: 1 cycle/min. Operation time: 2 sec./min. IDF220B to 370B standard.
(except L and T1 kits) Note 3) Available only for F, L and T1 kits. Note 4) IP65 is available only for L, T and S kits. Note) In case of CM indicate on a specification sheet.
A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26 22 19.5 13 12 17 10 9 10.5 11 22 45 6 46.5 5.5 30 10 40 M14 x 1.5 32 24 21 16 14 22 15 10 13.5
A U F N N ZZ + Stroke Z + Stroke S + Stroke L H RR (mm) A AL F FL G H H1 I K D B1 CX L KA CD E MM N Bore (mm) 0 -0.033 0 -0.033 0 -0.033 0 -0.039 20 M8 x 1.25 20 18 15.5 13 8 13 10 9 10.5 10 20 41 5 33.5 5 30 6 25 M10 x 1.25 26 22 19.5 13 10 17 10 9 10.5 10 20 45 6 37.5 5.5 30 8 32 M10 x 1.25 26 22 19.5 13 12 17 10 9 10.5 11 22 45 6 46.5 5.5 30 10 40 M14 x 1.5 32 24 21 16 14 22 15 10 13.5
n -rrt= I HH];+ tti : l l l O ! \ LLrJ \ F".k t t t I * DI"ENSIONS DIRECTIOI{AL AIR YALVE SUBPLATES SERIES NVSA 4)24 GLn.I'l; Sub.pletes ar3 heavy duty aluminum dl castings.
How to Order L 25 100 CG1Y Without auto switch L H7BW S 25 100 CDG1Y With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod End Male Thread Bore size (mm) 12 16 20 25 (mm) C1 9 10 12 15 H1 M5 x 0.8 M6 x 1.0 L1 14 15.5 18.5 22.5 X 10.5 12 14 17.5 M8 x 1.25 M10 x 1.25 Basic Style (mm) Without auto switch With auto switch Bore size (mm) Stroke range (mm) A 25.5 25.5 29 32.5 C D E F H I K L M N OA OB Q RA RB T B 22 22 24.5 27.5
D e D e Effective thread Effective thread 13 13 ZZ + 2 strokes S + Stroke 9 A K f N N f h + Stroke K A l + Stroke 9 l h Without air cushion S ZZ Stroke range Bore size (mm) Effective thread length Width across flats C B MB J K MM N P V W S ZZ A D Ee11 F G H 32 40 50 63 80 100 32.5 38 46.5 56.5 72 89 84 84 94 94 114 114 13 14 15.5 16.5 19 19 4 4 5 5 5 5 M6 x 1.0 M6 x 1.0 M8 x 1.25 M8 x 1.25
Select the graph that corresponds to the imaginary stroke l. l k Imaginary stroke l = (Stroke) + k + l k: Distance between the center and end of the plate 6 (Example) 1. When using CXSJM6-10 and l = 15 mm: Imaginary stroke l = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 (6) ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 2.
Select the graph that corresponds to the imaginary stroke l. l k Imaginary stroke l = (Stroke) + k + l k: Distance between the center and end of the plate 6 (Example) 1. When using CXSJM6-10 and l = 15 mm: Imaginary stroke l = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 (6) ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 2.
B E E F G H L L M Min. port size 2 x B L, L LQ3T11 4 3.5 10 9 4.8 9.5 11 28.5 27.5 14 2.5 LQ3T12 3 2 LQ3T21 6 4 17 16 6 12 16 34.5 33.5 20 4 LQ3T31 10 5 22.5 19.5 9 18 21 47.5 44.5 25 7.5 LQ3T32 8 6.4 LQ3T41 12 6 24 22 10 20 24 52.5 50.5 29 9.5 LQ3T51 19 7 26.5 24 14 28 32 64 61.5 37 16 LQ3T61 25 8 30 26 18 36 41 78 74 49 22 M (E, E) (E, E) G H L, L L, L (E,E): Reference dimension for the
OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) JEMANET (JPCN-1) Mitsubishi Electric Corp.: CC-LINK System Rockwell Automation: Allen Bradley Remote I/O (RIO) System NKE Corp.: Uni-wire H System 1 to 16 stations Kit L Kit L BB C D F1 J1 J2 K Q R1 R2 U V G H 3 to18 stations SD S Simple specials are available with SMC Simple Special System.
Standard type For 90 For 180 Positioning pin hole Positioning pin hole Counter-clockwise 3 3 A port A port A port 3 22.5 3 22.5 84 e 96 ng e 3 ra ng on ra ti B port n ta 3 90 tio 4 ro 7 ta m 1 Clockwise ro e e u s i g m w 3 m 6 k C n c l o ni a u 8 r Mi im 3 n 1 o ti e ax ta ng ro m M u ra m ni Mi 180 n tio e C s ta l i o w c k ro m mu xi Ma Positioning pin hole Positioning pin hole Position