Cable length Suffix 05 10 15 20 Nil C Extension cable 5 m Extension cable & connector 10 m 15 m 20 m Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure Alarm flag 1 6 Reservation 7 Reservation 8 CH1 abnormal rise of circulating fluid temperature 9
Cable length Suffix 05 10 15 20 Nil C Extension cable 5 m Extension cable & connector 10 m 15 m 20 m Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
COM3 15 LA Encoder A-phase pulse (differential line driver) Y004 CR 5 16 LAR (Note 15) COM2 17 LB Encoder B-phase pulse (differential line driver) 18 LBR X INP 10 19 LZ Encoder Z -phase pulse (differential line driver) 20 LZR X X RD 11 21 14 LG SD Control common OP LG Plate 14 SD Plate (Note 7) (Note 3, 5) Forced stop CN1 EM1 8 Servo-on SON 4 Reset (Note 10, 11) RES 3 Forward rotation stroke
Surface finish Ports Code Surface finish Ra max 15 in. (0.4 m) Standard 10 in. (0.25 m) No code M Ports 2 ports Code 2PW Specifications AP3130 AP3113 Normally closed (N.C.)
Model Size C10 A 10 ZP10C B 12 C 4 D 13 E F Y 1.7 7.7 7.7 8.2 9.5 9.5 10 13.7 14.7 12 12 12.5 14 14 14.5 18.5 19.5 3.8 ZP10U to 50U C13 13 ZP13C 15 4 13 1.8 C16 16 ZP16C 18 4 13 1.2 C20 20 ZP20C 23 4 15 1.7 C25 25 ZP25C 28 4 15 1.8 C32 32 ZP32C 35 4 15 2.3 C40 40 ZP40C 43 7 18 3.3 C50 50 ZP50C 53 7 18 Deep (D) ZP10D to 40D Model Size U02 A ZP02U B 2.6 C 1.2 D E F Y 2 4 6 8 10 13 16 20 25
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
type (Except for 6) Single clevis type (Non-integrated type) Double clevis type 10 15, 30, 45, 60, 75, 100 16 15, 30, 45, 60, 75, 100 20 15, 30, 45, 60, 75, 100 25 15, 30, 45, 60, 75, 100 Strokes are available in 1mm increments by installing spacers in standard stroke cylinders.
N Backlash Manual unlocking Theoretical Output 12 16 20 40 Rear end only 125 211 29 53 82 329 1mm Non-locking type only Standard Strokes (N) Operating pressure (MPa) Bore size (mm) Operating direction Piston area (mm) Bore size (mm) Standard stroke (mm) 0.2 10 8 23 17 40 30 63 47 98 72 161 121 251 188 0.4 20 15 45 34 80 60 126 94 196 143 322 241 502 377 0.3 15 11 34 25 60 45 94 71 147 107
15 HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 2 10 HED005-HW19 HED007-HW19 10 1.5 1.5 HED003-HW19 5 0.7 0.7 0 0 0 5 10 15 20 0 5 10 15 20 Flow rate (L/min) Flow rate (L/min) Pressure Loss in FacilityWater Circuit
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Abnormal low tank fluid level 1 Low tank fluid level 2 None 3 None 4 None 5 Fan failure Alarm flag 1 6 None 7 None 8 Abnormal rise of circulating fluid temperature 9 Circulating fluid temperature rise 10 Circulating fluid temperature drop 11 TEMP READY
(mm) Model Threaded Note) Flange Av x 10-6 m2 VNC1-6A VNC1-8A VNC1-10A VNC24-10A VNC2-10A VNC24-15A VNC2-15A VNC34-20A VNC3-20A VNC44-25A VNC4-25A VNC54-32A VNC5-32A VNC54-32F VNC5-32F VNC64-40A VNC6-40A VNC64-40F VNC6-40F VNC74-50A VNC7-50A VNC74-50F VNC7-50F 1 8 1 4 30 32 36 95 120 110 140 170 260 220 370 400 560 400 560 630 820 720 960 990 1500 1000 1600 0.3 0.2 7 3 8 11 15 11 15 14
The highest value in the past 15 seconds is displayed relative to the rated torque of 100%. 0 to 400 % 14 Instantaneous torque Torque that occurred instantaneously is displayed. The value of the torque that occurred is displayed in real time relative to the rated torque of 100%. 0 to 400 % 15 Within one-revolution position Position within one-revolution is displayed in encoder pulses.
The highest value in the past 15 seconds is displayed relative to the rated torque of 100%. 0 to 400 % 14 Instantaneous torque Torque that occurred instantaneously is displayed. The value of the torque that occurred is displayed in real time relative to the rated torque of 100%. 0 to 400 % 15 Within one-revolution position Position within one-revolution is displayed in encoder pulses.
Note Holding force N (Maximum static load) Equivalent to 0.5MPa Switch mounting screw (M3 x 0.5 x 10l) 32, 40 50, 63 80, 100 BQ-2 Standard Strokes Switch spacer Switch mounting nut Standard stroke (m) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Bore size (mm) 20, 25 32, 40, 50, 63, 80, 100 Applicable switch Reed switch Solid state switch D-F7/J79 D-F7V
Abnk pbr .8dy DXT201-15-1A Side ported NW325.41-O-O Applicau Yelv .
32 40 50 ZP50U 53 7 7 7 7 7 13 13 13 15 15 15 18 18 14.7 12 12 12 12 12 12 12.5 14 14 14.5 18.5 19.5 0.8 0.8 0.8 1 3 3 3.5 4 4 4.5 6.5 7.5 Put in the symbol for material at the end of model no.
Note Holding force N (Maximum static load) Equivalent to 0.5MPa Switch mounting screw (M3 x 0.5 x 10l) 32, 40 50, 63 80, 100 BQ-2 Standard Strokes Switch spacer Switch mounting nut Standard stroke (m) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Bore size (mm) 20, 25 32, 40, 50, 63, 80, 100 Applicable switch Reed switch Solid state switch D-F7/J79 D-F7V
Abnk pbr .8dy DXT201-15-1A Side ported NW325.41-O-O Applicau Yelv .
Fittings & Tubing Air Cylinders Rotary Actuators B LH 15 LT W 2 x LC (Knock pin position) Y X M W X Y 4 x LD LX Z LS + Stroke LZ ZZ + Stroke (mm) 7 7 6 6 LD 3 3 3 3 LT 4 4 4 4 LC 51 (60) 53 (61) 53 (61) 53 (61) LS Z 30 25 22 20 LH 135 (144) 125.5 (133.5) 123.5 (131.5) 118 (126) ZZ B 54 44 36 32 LX 4 3.5 3.5 3 M 16.5 16 15 15 X 8.5 8 7 7 Y 71 58 49 44 LZ 10 10 10 10 W Bore size 54.5 45 38.5