) L6 L8 Note 4) A2 M L7 L4 A1 Note 4) Weight (g) Note 5) Note 1) d D3 MAX.
Weight g Model d T D1 H D2 D3 L1 L4 L2 L3 Min. Max.
side traveling parallelism to B side C side w LEKFS25 0.04 0.02 LEKFS32 0.04 0.02 LEKFS40 0.04 0.02 D side * Traveling parallelism does not include the mounting surface accuracy.
Conduit terminal: VP3185-T A B DIN terminal: VP3185-D A B [110] 81 35 Light (For TL, TZ) Max.12 31.3 G1/2 Applicable cable 6 to 12 Light position (For DL, DZ) G1/2 NO NO PE PE [243] 237.6 239 228.5 213 31 31 130 130 52 52 41 41 105 105 [ ]: With indicator light (TL, TZ) 1312 Note) CE-compliant: D/DO only (Electrical entry) VP3145/3165/3185 Series Made to Order [Option] Please contact SMC
o p e r a t i o n p r i n c i p l e C u s h i o n s M a i n t e n a n c e I n s p e c t i o n P e r i o d i c i n s p e c t i o n D i sassem ble and reassem bl e C a u t i o n o f d i s a s s e m b l e D i s a s s e m b l i n g p r o c e d u r e A s s e m b l e p r o c e d u r e T r o u bl e s hoo t i n g Safety Instructions These safety instructions are intended to prevent
Lead wire Lateral type Lead wire Vertical type L L Space L 1 mm or more S O (mm) Lead wire type In-line electrical entry type Perpendicular electrial entry type Perpendicular electrial entry type Auto switch model D-M9 D-M9W D-M9V D-M9WV Finger position D-M9AVL D-M9AL Air gripper model Open MHK2-12 Closed 5 3 3 Open MHK2-16 Closed 5 1 3 3 Open MHK2-20 Closed 3 1 1 Open MHK2-25 Closed 4
BM2-032 BM2-040 D-C7, D-C8, D-H7 D-B5, D-B6, D-G5 D-A3A, D-A44A, D-G39A, D-K39A BM2-020 BM2-025 BA2-032 BA2-040 BA2-020 BA2-025 BM3-032 BM3-040 BM3-020 BM3-025 Caution Mounting Type and Accessories 1. Be careful of the snap ring springing out. When replacing the rod seal, take care that the snap ring does not spring out while you are removing it.
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
Recommended tightening torque Auto switch model Recommended tightening torque [Nm] D-M9 0.05 to 0.15 D-M9A (Water resistant) 0.05 to 0.10 Fig. 8 D-F8 0.10 to 0.20 Set screw Auto switch 29 - Auto switch proper mounting position at rotation end Table 11 Auto Switch Rotation range / Actuation / most sensitive position A A A A B B B B D-M9 D-F8 Magnet Operation range at optimum set position (
Target position (01-149) Posn failed D SVON Input
Position code (Order #1 #4, Port A D) Message code #4 #3 #2 #1 D C B A 0 0 1 0 0 0 0 1 0 0 0 1 Message code 0x2 Product No.1 A port Ex.: Short-circuit or over current error with the first slave of COM A port. Message code and corrective action for diagnostic error are shown below.
Enter in order starting from the first station on the D side.
Enter in order starting from the first station on the D side.
Enter in order starting from the first station on the D side.
(example: If the flow switch with output impedance of 1 k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) x1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V).
(mm) Applicable fitting size d 3.2 L Weight (g) D A M Model Urethane Soft nylon Applicable tubing KAR23-04 9.6 4 33.5 34.5 36.5 18.5 18.5 17.5 18 15.5 3.4 2.9 2.0 1.8 5 KAR04-06 KAR04-08 5.6 5.6 6 8 10.4 4 16 12.8 KAR04-10 39.5 37 39.5 10 3.3 2.5 KAR06-08 8 18.5 KAR06-10 6 12.8 KAR06-12 42 4.7 12 20 17 10 3.0 13.1 13.1 Applicable fitting size d 8 KAR08-10 41 4.0 18.0 18.0 10 20 18.5 15.2
Nil Without port (For manifold) (8A) 1 4 02 Electrical entry Light/Surge voltage suppressor CE-compliant CE-compliant G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire Electrical entry D T C H G Only"D" Symbol Nil S Z C Conduit Note) Note) T Conduit terminal Note) D DIN terminal Symbol S: With surge voltage suppressor Note) Refer to the figure below.
XLH-40 65 162.5 66 2 11 55 41 57 XLH-50 70 179.5 79 2 11 75 52 70 9 XL*-OMJ0005-C 5.