Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: M9BW, Lead

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Friction (Internal Resistance), End Locking: No, Cushion: Rubber cushion, Operating Pressure(MPa): 0.03 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper-zinc Material, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead

150 0400 N 0200 R XC10 Stroke B Dual Operation Double Rod Auto Switch Mounting Bore Stroke A Cushions Both Ends N w/o Cushions H Head End R Rod End Dimensions PC P + A Stroke P + B Stroke Y Y 4-EE (NPTF) R K DD AA D Across Flats D Across Flats KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in

In the case of mounting auto switch from B direction Step 2) Insert the auto switch into the auto switch installation groove from direction B. A B MHZ MHF Step 3) Slide the auto switch in the direction of the arrow until the indicator light illuminates.

Air Slide Table/Reversible Type 6, 8, 12, 16, 20, 25 Series MXQR How to Order MXQR 12 50 M9BW J L Made to Order Refer to page 2 for details. Air Slide Table/ Reversible Type Number of auto switches Port thread type 2 pcs. 1 pc. n pcs.

Cylinder with Lock Double Acting, Single Rod Series CNS 125, 140, 160 How to Order CNS L 100 125 D 100 D M9BW L CDNS 125 With auto switch With auto switch (Built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

Air Cylinder Series CS2 125, 140, 160 How to Order CS2 300 125 L M9BW With auto switch CDS2 L 125 300 With auto switch (Built-in magnet) Made to Order For details, refer to the next page. Mounting Number of auto switches B L F G C D T Basic Foot Rod flange Head flange Single clevis Double clevis Center trunnion 2 pcs. 3 pcs. 1 pc. n pcs.

Cylinder with Lock Double Acting, Single Rod 125, 140, 160, 180, 200, 250 Series CLS How to Order CLS L D 125 100 M9B M9B With Auto Switch CDLS M9BW L D 125 100 With auto switch (Built-in magnet) Cylinder unit auto switch Port thread type Nil TN TF Lock unit auto switch Nil Without auto switch Mounting style B L F G Rc NPT G Nil Without auto switch Select applicable auto switches from the

Air Cylinder Short Type Standard: Double Acting, Single Rod CG3 Series 20, 25, 32, 40, 50, 63, 80, 100 RoHS CJ1 How to Order CJP CJ2 L 25 CG3 100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto switch (Built-in magnet) CM3 Made to Order For details, refer to page 366.

Round Type Hydraulic Cylinder 20, 25, 32, 40 CHM Series 3.5 MPa How to Order CHM 25 100 L CHDM 25 100 M9BW L Auto switch mounting bracket Note) C With Auto Switch With auto switch (built-in magnet) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.)

Hydraulic Cylinder 20, 25, 32, 40 CHN Series 7 MPa CHQ How to Order CHK CHN CHN CHN 25 100 M9BW L C CHM Auto switch mounting bracket Note) Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.) Applicable to 20 only.

Air Cylinder Short Type Standard: Double Acting, Single Rod Series CM3 20, 25, 32, 40 RoHS How to Order CM3 L 40 150 M9BW With auto switch CDM3 L 150 40 With auto switch (Built-in magnet) Number of auto switches Rod end thread Nil S n Mounting 2 pcs. 1 pc. n pcs.