With cap SR 6.8 8.7 12 18 25 B 6.5 9 12.5 16 21 A MM h M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 B 4 4 6 6 6 C 12 14 19 27 36 MM B M8 x 1.0 M10 x 1.0 M14 x 1.5 M20 x 1.5 M27 x 1.5 C h1 h2 d f RBC08C RBC10C RBC14C RBC20C RBC27C RB08J RB10J RB14J RB20J RB27J RB08S RB10S RB14S RB20S RB27S 6 7.5 10 20 25 12 14 19 27 36 13.9 16.2 21.9 31.2 41.6 6.5 8 11 16 22 23 23 31 40 51 9 11 15 23 32

10 12 16 18 D M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 H 3.5 4 4 5 5 F C 22 27 32 41 41 MM K 4 7 8 8.5 13 RBQC1604 RBQC2007 RBQC2508 RBQC3009 RBQC3213 RBQ1604 RBQ2007 RBQ2508 RBQ3009 RBQ3213 14.2 18.2 23.2 28.2 30.2 14 18 23 28 30 7 9 10 12 13 31 44.5 52 61.5 76 27 37.5 44 53 63 25.4 31.2 37 47.3 47.3 6 6 6 6 6 RS H A RZQ MI W S Replacement Parts Hexagon Nut Option CEP1 (2 pcs. standard

D-R Note 3) Options for 2, 6, and 8 can not be specified at the same time. (Ex.) 68 Note 4) Symbols 9, D, J can not be specified at the same time. (Ex.) 9-D-J Note 5) For products with auto drain, either symbol D or J cannot be specified at the same time because of female threads (3/8 or 1/8), for connection to drain piping.

Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 A A B B Bore size 6 10 16 (4.5) 5.5 (4.5) 5.5 (0.5) 1.5 (0.5) 1.5 (5) 6 (5) 6 (1) 2 (1) 2 (5.5) 6.5 (5.5) 6.5 (1.5) 2.5 (1.5) 2.5 The values in ( ) are measured from the end of the auto switch mounting bracket.

Standard dimensions marked with * will be as follows to the rod diameter (D). Enter any special dimension you require. D 6 D 1 mm, 6 < D 25 D 2 mm, D > 25 D 4 mm 3. In the case of the double rod type and single acting retraction type, enter the dimensions when the rod is retracted. 4. Only one side of a double rod can be manufactured. 5.

Auto Switch Internal Circuit D-A90 (V) Contact protection box OUT () Brown Reed switch Unit: g Weight Table CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93 (V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96

26.5 29.5 23.5 36.5 30.5 37.5 31.5 14 Series RQ Operation Range mm 100 Switch model Bore size 25 32 40 50 63 20 80 D-A7, A80 D-A7H, A80H D-A73C, A80C 12 12 12 12 12 11 10 13 16 11.5 15 9 13 13 13 14 14 9.5 9.5 9.5 17 11.5 D-A79W D-A9, A9V D-F7, F7V D-J79, J79C, J79W D-F7W, F7WV D-F79F, F7BAL D-F7BAVL 5.5 5 6 6 6 6.5 6.5 7 7 7 8 7 8 8.5 8 9 D-F7LF D-F9, F9V D-F9W, F9WV D-F9BAL 5.5 5.5

D0 0 2 2 4.5 4.5 9.5 9.5 134.5 144.5 89 87.5 88 87.5 -X Operating Range 20D-Z7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL Auto switch model Bore size (mm) Data 125 140 160 14 D-Z7/Z80 14.5 13 Hs A D-A3/A44 D-A5/A6 10 10 10 17 17 17 D-A59W Ht D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV 12 13 7 6 6 7 D-Y7BAL D-F59F/F5/J5 D-F5W/J59W D-F5BAL/F5NTL B 5 5 5.5 Proper Auto Switch Mounting

Content 10 MXP10-PS No. 19 above (2 sets) 12 MXP12-PS 16 MXP16-PS 6 Series MXP Dimensions MXPJ6 4-M3 x 0.5 depth 3 7 5 H 3 D B 18 1 0.05 3.5 16.5 14 13 20 6 F 6 6 5 2-M4 x 0.7 Piping port 13.5 Prepared hole dia. 3.3 2-M3 x 0.5 (Plug: M-3P) 17 0.05 Mounting reference planes B D M Stroke: S 1 5 J Z 2.4 Piping port 2-M3 x 0.5 (mm) MXPJ65 MXPJ6-10 SMXPJ6, #1 SMXPJ6, #2 F H J M S Z Model 25 38

D-A9V 10 6 6 8.5 10 D-M9 D-M9V D-M9W D-M9WV 3.5 3.5 5 6 5.5 MXH Interference MXU Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming approximately 30% dispersion).

Auto Switch Internal Circuit D-A90(V) Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Auto switch model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93

state switch HS A B D-F7V D-J79C D-F7WV D-F7BAVL D-A7 D-A80 D-A73C D-A80C D-A79W 32, 40 D-A7 D-A80 D-A73C D-A80C D-A79W D-F7V D-F7BAVL D-F7WV D-J79C Auto switch model A B Hs A B Hs A B Hs A B Hs A B Hs Symbol Standard Stroke Bore size (mm) 32 40 38.5 42 38 41.5 6.5 9 6.5 9 6 (6.5) 9.5 13.5 3.5 6 34 37.5 9.5 13.5 6.5 9 35 38.5 9 (9.5) 31.5 35 6.5 10.5 9.5 13.5 8.5 (9) 13 (13.5) Long Stroke

6 15/22 18/23 3/4 5/6 9/10 13/14 6/7 13/14 Rc 1/2 Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass 3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation 10% 20 14 30 23 30 20 25 60 46 Refer to page 94.

66.5 67.5 68.5 74.5 71 74 70 76.5 835 Series CLQ Operating Range (mm) Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-A9/A9V 10 10 9.5 9.5 9.5 11.5 9 11.5 D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL 4.5 4.5 5 5 6 6.5 6.5 7.5 D-A7/F7H D-A73C D-A80/A80H D-A80C D-A79W 12 11 10 12 12 13 13 14 14 16 15 17 D-F7/F7V D-J79/J79C D-F7W/F7WV D-J79W D-F7BAL/F7BAVL D-F7NTL/F79F 6 6 6 6.5 6.5 7

(On-line state) I/O connection, time-out (communication irregularity in light degrees) MAC ID duplication error, or BUS OFF error (communication error in serious conditions) SW2 SW1 OFF OFF 6 5 4 3 2 1 ON 10 9 8 7 6 5 4 3 2 1 ON ON ON MNS MNS PWR(V) PWR COM C COM D COM A COM B INPUT COM A to D When COM A to D are receiving data. When COM A to D are not receiving data.

Black 6 A A-5 Orange 9 B B-6 Nil Robotic type B A-6 Black 8 3 (d) cable Signal name Terminal number S Standard cable Red 4 Lock (+) B-1 Black 5 Lock (-) A-1 Brown 1 Sensor (+) B-3 Sensor (-) A-3 Blue 2 Actuator side Controller side (8) (14.2) (a) (b) A1 B 2 1 (17.7) 1 (14) (18) A6 B6 5 6 (10.2) 2 1 B1 A1 B3 A3 (d) (5.7) 15 16 (c) L (11) (30.7) 10.6 Actuator cable [For sensor/ with lock (

D-G79/K79/K79C D-H7/H7W D-H7BAL/H7NF D-H7C 8 10 9 10 10 BMA2-020 BMA2-025 BMA2-032 BMA2-040 BMA2-050 8 10 9 10 10 13 13 14 14 14 8 10 9 10 10 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL/G59F D-G5NTL D-G5NBL 4 4 4.5 5 6 7 8.5 9 10 9.5 BA-01 BA-02 BA-32 BA-04 BA-05 D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL 4 4 4.5 5 6 D-G59F D-G5NBL D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C 5 5 5.5 6 7 35 40 40 45 45

Model A B Same side Different sides 4 6.5 8 8 Different sides Same side D-C7, D-C8 31.5 29.5 31 31 n-2 2 15 + 45 ( ) (n = 2, 4, 6...) Approx. Hs D-C7, D-C8 30.5 35 40.5 40.5 50 + 45 (n-2) 15 50 A B 4 6.5 8 8 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) D-C73C 31.5 29.5 31 31 D-C73C 15 65 65 + 50 (n-2) Approx. Hs 33 37.5 43 43 n-2 2 D-H7, D-H7W D-H7F 15 + 45 ( ) (n = 2, 4, 6...)