SMC Corporation of America
Elite Part Number Search
Search Results "ARG20-01G1-N-B"

PBT 2 B Port plug 2 Bonnet PBT, HNBR Refer to page 705.

Description Material Note 1 Body Aluminum alloy Anodized 2 Branch passage PPS 3 Gasket HNBR 4 Sensor base PPS 5 Gasket HNBR 6 Sensor Au, Pt, Al2O3 Dimensions A B 70 H F E D 1.5 OUT IN 4 x P L K 2 x Port size N Symbol Model Port size A B D E F H K L N P PF3A703H Rc1, NPT1, G1 130 45 79.1 55.3 22.5 25 35 60 30 M4 x 0.7 depth 7 PF3A706H Rc1 1/2, NPT1 1/2, G1 1/2 170 60 94.1 70.3 30 68 45

Option Symbol and Composition Option Symbol and Composition Main body, shading coil material Holder material (in core ass'y) Option symbol Seal material Coil insulation type Main body, shading coil material Standard A B D E F G H J L N P T X Option symbol Seal material Coil insulation type NBR FKM Standard A B D E F G H J L N P T X NBR FKM B Polyacetal B FKM EPDM Brass or BC6, Copper FKM

C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L C A B C D C4L 15.2 17.5 4 8.2 C6L 15.2 18.3 4 10.4 N7L 20.9 20.6 6 11.1 -64No.PS-OMS0006CN-G A B -65No.PS-OMS0006CN-G 0.5~7 + 0.5~7 -66No.PS-OMS0006CN-G 2 (n ) <> <> (n -1) (n -1) -67No.PS-OMS0006CN-G Revision history A B [2016 9 ] C [2018 6 ] D [2020 2 ] E [2021 2 ] F [2022 1 ] G [2022 10 ] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN

N None 1 2 n T 7 Digital Gap Checker With Control Unit ISA3 Series 3-Color Display RoHS How to Order G C N M B 2 ISA3 L 1 Rated distance range F 0.01 to 0.03 mm G 0.02 to 0.15 mm H 0.05 to 0.30 mm 2 port solenoid valve Rated voltage Piping specifications Output specifications Nil 24 VDC 1 *11 100 VAC 2 *11 110 VAC *11: Made to Order N NPN output P PNP output Supply side Detection side Unit

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.

Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 0.5 40 8 0.5 Gripping force (N) Gripping force (N) 0.4 30 6 0.4 0.3 0.3 20 4 0.2 0.2 10 2 0.1 0.1 0 20 30 50 60 Gripping point L (mm) 40 0 30 40 60 70 Gripping point L (mm) 50 80 MHY2-16D MHY2-25D F F F F 35 100 Pressure 0.6 MPa Pressure 0.6 MPa 30 0.5 0.5 80 Gripping force (N) Gripping force (N) 25 External grip 0.4 0.4

A modular style regulator with built-in pressure gauge, series ARG offers an optional, built-in backflow mechanism which enables reliable discharge of air pressure from outlet to inlet.  The mounting angle of the pressure gauge is selectable depending on the piping direction, and with the anti-revolving mechanism (PAT.PEND.), the pressure gauge will not be revolved even after the handle

sealing method Options Flat gasket (D.O.E) 1 N/A Bracket Quick plug Nil B P Note) Specity seal material in place of "" (N for NBR or V for FPM). 4.

N 306 115 6 1700 N 3 325 134 7 2000 N 449 191 10 6000 N 487 229 12 8500 N 611 287 15 Note) Load on mounting frame is at room temperature (20 to 25C). 916 478 25 Caution 4.

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

1 For details about certified products conforming to international standards, visit us at www.smcworld.com. 3 Port Pilot Operated Poppet Solenoid Valve Rubber Seal Series VP300/500/700 How to Order V100 A 2 4 3 VP B E 1 SY With bracket F Option SYJ Series VP solenoid valve Thread type (Only VP342, 542 or 742.) VK Nil F N T Rc G NPT NPTF Passage symbol Body size N.C.

The "B"port can either be plugged or unplugged. Model Suitable tightening torque VQZ100 0.13 to 0.19Nm VQZ200 0.25 to 0.35Nm SY 5 port valve 3 port valve VQZ300 0.5 to 0.7Nm SYJ When port plug is used on B port, indicate "CM" in manifold part No. and port size, and supecify the port plug location on the manifold specification form.

GPM gal (US) Hysteresis mode OFF n-1 n-2 GPM = gal (US) /min Large flow rate "n" H (fixed hysteresis) = 3 digits H H ON Window comparator mode NO OFF n-1 n-2 Large flow rate 19 Series PFA/PFW Digital Flow Switch for Air/Water Flow Rate Setting Flow rate setting mode (manual) 1. Setting Value Input Mode (Manual) 2. Setting in the Manual Mode 3.

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.